Effects of storage temperature and time on metabolite profiles measured in dried blood spots, dried blood microsamplers, and plasma

被引:3
|
作者
Petrick, Lauren M. [1 ,2 ,3 ]
Niedzwiecki, Megan M. [1 ,2 ]
Dolios, Georgia [1 ]
Guan, Haibin [1 ]
Tu, Peijun [1 ]
Wright, Robert O. [1 ,2 ]
Wright, Rosalind J. [1 ,2 ,4 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Environm Med & Publ Hlth, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Inst Expos Res, New York, NY USA
[3] Sheba Med Ctr, Bert Strassburger Metab Ctr, Tel Hashomer, Israel
[4] Icahn Sch Med Mt Sinai, Dept Pediat, New York, NY USA
基金
美国国家卫生研究院;
关键词
Dried blood spots; Microsamplers; Storage conditions; Temperature; Metabolomics; Exposome; FILTER-PAPER; STABILITY; METABOLOMICS; SAMPLES; SERUM;
D O I
10.1016/j.scitotenv.2023.169383
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The practical advantages of capillary whole blood collection over venipuncture plasma collection for human exposome research are well known. However, before epidemiologists, clinicians, and public health researchers employ these microvolume sample collections, a rigorous evaluation of pre-analytical storage conditions is needed to develop protocols that maximize sample stability and reliability over time. Therefore, we performed a controlled experiment of dried whole blood collected on 10 mu L Mitra microsamplers (DBM), 5-mm punches of whole blood from a dried blood spot (DBS), and 10 mu L of plasma, and evaluated the effects of storage conditions at 4 degrees C,-20 degrees C, or-80 degrees C for up to 6 months on the resulting metabolite profiles measured with untargeted liquid chromatography-high resolution mass spectrometry (LC-HRMS). At-80 degrees C storage conditions, metabolite profiles from DBS, DBM, and plasma showed similar stability. While DBS and DBM metabolite profiles remained similarly stable at-20 degrees C storage, plasma profiles showed decreased stability at-20 degrees C compared to-80 degrees C storage. At refrigerated temperatures (4 degrees C), metabolite profiles collected on DBM were more stable than plasma or DBS, particularly for lipid classes. These results inform robust capillary blood sample storage protocols for DBM and DBS at potentially warmer temperatures than-80 degrees C, which may facilitate blood collections for populations outside of a clinical setting.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of maternal venous blood metabolomics collected as dried blood spots, dried blood microsamplers, and plasma for integrative environmental health research
    Petrick, Lauren
    Guan, Haibin
    Page, Grier P.
    Dolios, Georgia
    Niedzwiecki, Megan M.
    Wright, Robert O.
    Wright, Rosalind J.
    ENVIRONMENT INTERNATIONAL, 2024, 187
  • [2] Evaluation of glucuronide metabolite stability in dried blood spots
    Bowen, Chester L.
    Volpatti, Jonathan
    Cades, Jessica
    Licea-Perez, Hermes
    Evans, Christopher A.
    BIOANALYSIS, 2012, 4 (23) : 2823 - 2832
  • [3] The effect of storage and temperature on the stability of steroid hormones in dried blood spots
    Olthof, Anouk
    Wickenhagen, Wjera
    Hillebrand, Jacquelien
    Boelen, Anita
    Heijboer, Annemieke
    HORMONE RESEARCH IN PAEDIATRICS, 2023, 96 : 78 - 79
  • [4] Measurement of troponin-T in dried blood spots and dried plasma spots: A pilot study
    Almagor, Yotam
    Eventov-Friedman, Smadar
    Nir, Amiram
    Sror, Awad
    Saada, Ann
    JOURNAL OF PEDIATRIC BIOCHEMISTRY, 2014, 4 (03) : 153 - 157
  • [5] Stability of ceftolozane in human plasma and dried blood spots: Implications for transport and storage
    Martens-Lobenhoffer, Jens
    Hinderhofer, Matthias
    Troeger, Uwe
    Bode-Boeger, Stefanie M.
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2020, 103
  • [6] Bioassay studies of Risperidone and its active metabolite in rat dried blood spots and dried plasma spots using LC-ESI-MS/MS: Comparison of their pharmacokinetic profiles
    Challa, Gangu Naidu
    Nimmu, Narendra Varma
    Bondigalla, Ramachandra
    Arnipalli, Manikanta Swamy
    SEPARATION SCIENCE PLUS, 2020, 3 (10) : 444 - 450
  • [7] Application of dried plasma and blood spots in sterol analysis
    不详
    BIOANALYSIS, 2010, 2 (03) : 383 - 383
  • [8] Estimating blood volume on dried blood spots
    Seo, Sung -Hee
    Batterman, Stuart
    FORENSIC CHEMISTRY, 2024, 37
  • [9] The effects of iron injection on blood doping biomarkers in dried blood spots
    Loria, Francesco
    Maret, Estelle
    Schobinger, Celine
    Kuuranne, Tiia
    Grabherr, Silke
    Leuenberger, Nicolas
    DRUG TESTING AND ANALYSIS, 2023, 15 (04) : 444 - 448
  • [10] Effect of temperature on lysosomal enzyme activity during preparation and storage of dried blood spots
    Supriya, Manjunath
    De, Tanima
    Christopher, Rita
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (01)