Calibration of a compact ASIC-based data acquisition system for neutron/γ discrimination and spectroscopy with organic scintillators

被引:0
|
作者
Wu, T. C. [1 ]
Sutanto, F. [2 ]
Li, V. A. [2 ]
Classen, T. M. [2 ]
Dazeley, S. [2 ]
Jovanovic, I. [1 ]
机构
[1] Univ Michigan, Dept Nucl Engn & Radiol Sci, Ann Arbor, MI 48109 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
关键词
Fast-neutron detection; Pulse-shape discrimination; SiPM readout; PLASTIC SCINTILLATORS; MODEL;
D O I
10.1016/j.nima.2023.168699
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. The calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and gamma sources.
引用
收藏
页数:7
相关论文
共 34 条
  • [31] The Multi Unit Activity analyzer:: a Windows™ based hardware-software system for low cost, high speed analog to digital data conversion, data acquisition and window discrimination
    Van den Saffele, JK
    Schoonjans, F
    De Gruytere, D
    Gao, C
    Kaufman, JM
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1998, 56 (03) : 273 - 275
  • [32] Compact FPGA-Based Data Acquisition System for a High-Channel, High-Count-Rate TOF-PET Insert for Brain PET/MRI
    Dong, Qian
    Sajedi, Salar
    Cui, Ke
    Levin, Craig S.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 9
  • [33] Development of a single-shot CCD-based data acquisition system for time-resolved X-ray photoelectron spectroscopy at an X-ray free-electron laser facility
    Oura, Masaki
    Wagai, Tatsuya
    Chainani, Ashish
    Miyawaki, Jun
    Sato, Hiromi
    Matsunami, Masaharu
    Eguchi, Ritsuko
    Kiss, Takayuki
    Yamaguchi, Takashi
    Nakatani, Yasuhiro
    Togashi, Tadashi
    Katayama, Tetsuo
    Ogawa, Kanade
    Yabashi, Makina
    Tanaka, Yoshihito
    Kohmura, Yoshiki
    Tamasaku, Kenji
    Shin, Shik
    Ishikawa, Tetsuya
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 183 - 192
  • [34] Data-independent acquisition-based SWATH-MS proteomics profiling to decipher the impact of farming system and chicken strain and discovery of biomarkers of authenticity in organic versus antibiotic-free chicken meat
    Alessandroni, Laura
    Sagratini, Gianni
    Bravo, Susana B.
    Gagaoua, Mohammed
    CURRENT RESEARCH IN FOOD SCIENCE, 2024, 8