Shear capacity of corroded high-strength bolted connections

被引:2
|
作者
Lian, Fengmei [1 ]
Zhao, Bingzhen [3 ]
Li, Tianhe [2 ]
Jin, Zeyuan [2 ]
Zhao, Zhongwei [2 ]
机构
[1] Liaoning Tech Univ, Coll Architecture & Transportat, Fuxin 123000, Peoples R China
[2] Liaoning Tech Univ, Sch Civil Engn, Fuxin 123000, Peoples R China
[3] Shaanxi Construct Engn Grp Co Ltd, Xian 710082, Peoples R China
关键词
High -strength bolt; Random corrosion; Clamping force; Stochastic numerical analysis; Mass loss ratio; SUBSET SIMULATION; MODEL; PIPELINES; BEHAVIOR; TIMBER;
D O I
10.1016/j.ijpvp.2023.104981
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The bolted connection is one of the most commonly adopted connection types in steel structures. The high strength bolted connection is always used in important steel structures. Corrosion is inevitable for bolted connections. To clearly reveal the influence of corrosion on the clamping force of high strength bolts, the stochastic numerical model of randomly corroded bolt connections is established. The whole corrosion process can be simulated through the established stochastic numerical model. The influences of uniform corrosion and random corrosion are analyzed. The change rule of clamping force along with mass loss ratio is analyzed. The random distribution of clamping force corresponding to specific mass loss ratio of bolt head is clarified. The probabilistic distribution of clamping force of randomly corroded bolts is revealed. The simplified numerical model of bolt group connection is proposed. The stochastic numerical analysis can be performed based on this simplified model. The results indicated that it is unsafe if the random pitting corrosion is simplified as uniform corrosion. The corrosion location has obvious on the changing rule of residual clamping force.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Experimental study on bearing capacity of corroded high-strength bolt connections under shear force
    Kong, Zhengyi
    Yang, Fan
    Jin, Ya
    Hong, Shaozheng
    Wang, Xueqing
    Vu, Quang-Viet
    Truong, Viet-Hung
    Yu, Bo
    Kim, Seung-Eock
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 309
  • [2] Strength of Bolted Lap Shear Connections with Advanced High-Strength Steel Sheets
    Ding, Chu
    Xia, Yu
    Li, Zhanjie
    Blum, Hannah B.
    Schafer, Benjamin W.
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (01)
  • [3] Shear Capacity of High-Strength Bolts in Long Connections
    Tide, Raymond H. R.
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION, 2017, 54 (01): : 61 - 67
  • [4] Ductility and Strength of High-strength Bolted Connections for High-strength Constructional Steels
    Li, Guo-Qiang
    Lyu, Yi-Fan
    Wang, Yan-Bo
    ce/papers, 2022, 5 (04): : 28 - 35
  • [5] Test on shear behavior of less-tightened high-strength bolted connections
    Lin, Quan
    Xue, Xiaolei
    Guo, Zhan
    Zhao, Yang
    Chen, Yu
    STRUCTURES, 2021, 34 : 3622 - 3639
  • [6] Double shear tests of high-strength steel bolted connections with reduced tightening
    Zhang, Xiaoyong
    Lin, Xiang
    Sun, Linhao
    Lei, Yongchun
    Chen, Jincheng
    Lin, Hengzhou
    Chen, Yu
    JOURNAL OF BUILDING ENGINEERING, 2022, 46
  • [7] HIGH-STRENGTH BOLTED CONNECTIONS SUBJECT TO PRYING
    KRISHNAMURTHY, N
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (01): : 299 - 300
  • [8] LACK OF FIT IN HIGH-STRENGTH BOLTED CONNECTIONS
    MANN, AP
    MORRIS, LJ
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1984, 110 (06): : 1235 - 1252
  • [9] HIGH-STRENGTH BOLTED CONNECTIONS SUBJECT TO PRYING
    AGERSKOV, H
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1976, 102 (01): : 161 - 175
  • [10] HIGH-STRENGTH BOLTED CONNECTIONS SUBJECT TO PRYING
    AGERSKOV, H
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1977, 103 (10): : 2066 - 2068