Evaluation of Interobserver and Intraobserver Differences of Graf Method in Developmental Hip Dysplasia

被引:0
|
作者
Dogrul, Halil [1 ]
Baymurat, Alim Can [2 ]
Tuncay, Ismail Cengiz [3 ]
Atalar, Hakan [2 ]
机构
[1] Etimesgut Sehit Sait Erturk State Hosp, Dept Orthopaed & Traumatol, Ankara, Turkiye
[2] Gazi Univ, Dept Orthopaed & Traumatol, Med Fac, Ankara, Turkiye
[3] Baskent Univ Ankara Hosp, Dept Orthopaed & Traumatol, Ankara, Turkiye
来源
GAZI MEDICAL JOURNAL | 2023年 / 34卷 / 04期
关键词
Developmental hip dysplasia; ultrasonography; Graf method; interobserver; intraobserver; ULTRASONOGRAPHY; AGREEMENT; CLASSIFICATION; DISLOCATION;
D O I
10.12996/gmj.2023.86
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The aim of this study was to evaluate possible differences in hip ultrasonography (US) results between physicians working in different medical centers. Method: In this study, a total of 117 horizontal US images representing all sonographic types of developmental dysplasia of the hip (DDH) were utilized. Four experienced researchers independently measured the 117 US images at different times. The results obtained by each researcher were documented separately, including alpha and beta angles, Graf types. All of the collected data were analyzed statistically to assess for interobserver and intraobserver variability. Results: The study found that the average change between the alpha angles ranged from a minimum of 1 to a maximum of 4. The mean change between the beta angles was wider, ranging from a minimum of 1.8 to a maximum of 8.2. To evaluate the differences between the Graf hip typologies, paired groups were formed and Cohen's Kappa method was used. For the first group k= 0.661, for the second group k= 0.671, for the third group K= 0.647, for the fourth group k= 0, 718, k= 0.717 for the fifth group and k= 0.637 for the sixth group. Interobserver Kappa evaluation results (k=0.647) showed moderate and significant agreement. Conclusion: The results revealed a moderate to substantial level of agreement between the researchers. Based on these findings, it was concluded that the use of US for screening and follow-up of the Graf hip typing method should be performed by experienced professionals.
引用
收藏
页码:425 / 431
页数:7
相关论文
共 50 条
  • [1] Ultrasonographic screening for developmental dysplasia of the hip: the Graf method revisited
    Kolovos, Stylianos
    Sioutis, Spyridon
    Papakonstantinou, Maria-Eleni
    Serenidis, Dimitrios
    Altsitzioglou, Pavlos
    Karampikas, Vasileios
    Chlapoutakis, Konstantinos
    Mitsiokapa, Evanthia
    Katsanos, Spyridon
    Mastrokalos, Dimitrios
    Koulalis, Dimitrios
    Papagelopoulos, Panayiotis J.
    Mavrogenis, Andreas F.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (02): : 723 - 734
  • [2] Ultrasonographic screening for developmental dysplasia of the hip: the Graf method revisited
    Stylianos Kolovos
    Spyridon Sioutis
    Maria-Eleni Papakonstantinou
    Dimitrios Serenidis
    Pavlos Altsitzioglou
    Vasileios Karampikas
    Konstantinos Chlapoutakis
    Evanthia Mitsiokapa
    Spyridon Katsanos
    Dimitrios Mastrokalos
    Dimitrios Koulalis
    Panayiotis J. Papagelopoulos
    Andreas F. Mavrogenis
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 723 - 734
  • [3] Assessment of variations in the measurement of hip ultrasonography by the Graf method in developmental dysplasia of the hip
    Ömeroglu, H
    Biçimoglu, A
    Koparal, S
    Seber, S
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2001, 10 (02): : 89 - 95
  • [4] Interobserver and Intraobserver Reliability in the Salter Classification of Avascular Necrosis of the Femoral Head in Developmental Dysplasia of the Hip
    Schaeffer, Emily K.
    Ponton, Ethan
    Sankar, Wudbhav N.
    Kim, Harry K. W.
    Kelley, Simon P.
    Cundy, Peter J.
    Price, Charles T.
    Clarke, Nicholas M. P.
    Wedge, John H.
    Mulpuri, Kishore
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2022, 42 (01) : E59 - E64
  • [5] Limited Intraobserver and Interobserver Reliability for the Common Measures of Hip Joint Congruency Used in Dysplasia
    Larson, A. Noelle
    Rabenhorst, Brien
    De la Rocha, Adriana
    Sucato, Daniel J.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (05) : 1414 - 1420
  • [6] Interobserver agreement and clinical disparity between the Graf method and femoral head coverage measurement in developmental dysplasia of the hip screening A prospective observational study of 198 newborns
    Chang, Wen-Chieh
    Hsu, Kuei-Hsiang
    Lo, I. -Fang
    Liao, Kai-Hao
    Su, Yu-Ping
    MEDICINE, 2021, 100 (24) : E26291
  • [7] MRI versus computed tomography as an imaging modality for postreduction assessment of irreducible hips in developmental dysplasia of the hip: an interobserver and intraobserver reliability study
    Barkatali, Bilal M.
    Imalingat, Herbert
    Childs, James
    Baumann, Andreas
    Paton, Robin
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2016, 25 (06): : 489 - 492
  • [8] Frequency of Developmental Dysplasia of Hip Detected by Graf'S Ultrasonographic Method in Icteric Newborns: A Preliminary Study
    Jalli, R.
    Foroughi, A. A.
    Lotfi, M.
    Mohammadhoseini, M.
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2010, 12 (04) : 458 - 462
  • [9] Diagnostic Accuracy of Ultrasonography Method of Graf in the Detection of Developmental Dysplasia of the Hip: A Meta-Analysis and Systematic Review
    Chavoshi, Mohammadreza
    Mirshahvalad, Seyed Ali
    Mahdizadeh, Mehrzad
    Zamani, Fatemeh
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2021, 9 (03): : 297 - 305
  • [10] Interpreting neonatal hip sonography: intraobserver and interobserver variability
    Pedrotti, Luisella
    Crivellari, Ilaria
    Degrate, Alessandro
    De Rosa, Federica
    Ruggiero, Francesca
    Mosconi, Mario
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2020, 29 (03): : 214 - 218