A sub-picosecond digital clock monitoring system

被引:2
|
作者
Saradhy, Rohith [1 ]
Frahm, Erich [1 ]
Mendes, Eduardo B. S. [2 ]
Rusack, Roger [1 ]
机构
[1] Univ Minnesota, Minneapolis, MN 55455 USA
[2] CERN, Geneva, Switzerland
关键词
Digital electronic circuits; Timing detectors;
D O I
10.1088/1748-0221/18/01/T01003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a low-cost system designed to monitor wander in digital clocks with a precision of <= 1 ps. With this system we have shown that it is possible to track phase variations at the sub-picosecond level by adding noise to a reference clock. As in many cases where a clock is part of a complex distribution network small changes in temperature and other effects can lead to small changes in the clock's phase. As a further demonstration of the system, we have used it to measure the phase changes induced in optical signals in fibers.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] SUB-PICOSECOND SPECTROSCOPY
    IPPEN, EP
    SHANK, CV
    PHYSICS TODAY, 1978, 31 (05) : 41 - &
  • [2] Measurement and spice prediction of sub-picosecond clock jitter in A/D converters
    Zanchi, A
    Papantonopoulos, I
    Tsay, F
    PROCEEDINGS OF THE 2003 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL V: BIO-MEDICAL CIRCUITS & SYSTEMS, VLSI SYSTEMS & APPLICATIONS, NEURAL NETWORKS & SYSTEMS, 2003, : 557 - 560
  • [3] Dual sub-picosecond and sub-nanosecond laser system
    谢兴龙
    刘凤翘
    杨镜新
    杨鑫
    李美荣
    薛之玲
    高奇
    管富义
    张伟清
    黄关龙
    庄亦飞
    韩爱妹
    林尊琪
    ChineseOpticsLetters, 2003, (11) : 658 - 660
  • [4] Large dynamic range digital delay with sub-picosecond precision
    Dehmeshki, Diba
    Eberle, Zachariah
    Frahm, Erich
    Rusack, Roger
    Saradhy, Rohith
    Tousi, Yahya
    JOURNAL OF INSTRUMENTATION, 2024, 19 (04):
  • [5] Digital in-line holography with a sub-picosecond laser beam
    Nicolas, F.
    Coetmellec, S.
    Brunel, M.
    Lebrun, D.
    OPTICS COMMUNICATIONS, 2006, 268 (01) : 27 - 33
  • [6] Design and development of a sub-picosecond pulse radiolysis system
    Muroya, Y
    Watanabe, T
    Wu, G
    Li, X
    Kobayashi, T
    Sugahara, J
    Ueda, T
    Yoshii, K
    Uesaka, M
    Katsumura, Y
    RADIATION PHYSICS AND CHEMISTRY, 2001, 60 (4-5) : 307 - 312
  • [7] SUB-PICOSECOND OPTICAL CHRONOSCOPY
    BRADLEY, DJ
    SIBBETT, W
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1975, 11 (09) : D25 - D26
  • [8] Laser processing of sapphire with picosecond and sub-picosecond pulses
    Ashkenasi, D
    Rosenfeld, A
    Varel, H
    Wahmer, M
    Campbell, EEB
    APPLIED SURFACE SCIENCE, 1997, 120 (1-2) : 65 - 80
  • [9] A sub-picosecond pulsed 5 MeV electron beam system
    Farrell, JP
    Batchelor, K
    Meshkovsky, I
    Pavlishin, I
    Lekomtsev, V
    Dyublov, A
    Inochkin, M
    Srinivasan-Rao, T
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, 2001, 576 : 787 - 790
  • [10] Sub-picosecond aperture uncertainty measurements
    Chiorboli, G
    IMTC/2001: PROCEEDINGS OF THE 18TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3: REDISCOVERING MEASUREMENT IN THE AGE OF INFORMATICS, 2001, : 1709 - 1713