Automatic 3D CT liver segmentation based on fast global minimization of probabilistic active contour

被引:2
|
作者
Jin, Renchao [1 ,3 ]
Wang, Manyang [1 ]
Xu, Lijun [2 ]
Lu, Jiayi [1 ]
Song, Enmin [1 ]
Ma, Guangzhi [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Comp Sci & Technol, Wuhan, Hubei, Peoples R China
[2] Hubei Univ, Sch Comp & Informat Engn, Wuhan, Peoples R China
[3] Huazhong Univ Sci & Technol, Sch Comp Sci & Technol, Wuhan 430074, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
B-spline surface fitting; liver segmentation; CT; probabilistic active contour; variational method; IMAGE SEGMENTATION; SHAPE MODEL; NETWORK;
D O I
10.1002/mp.16116
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeAutomatic liver segmentation from computed tomography (CT) images is an essential preprocessing step for computer-aided diagnosis of liver diseases. However, due to the large differences in liver shapes, low-contrast to adjacent tissues, and existence of tumors or other abnormalities, liver segmentation has been very challenging. This study presents an accurate and fast liver segmentation method based on a novel probabilistic active contour (PAC) model and its fast global minimization scheme (3D-FGMPAC), which is explainable as compared with deep learning methods. MethodsThe proposed method first constructs a slice-indexed-histogram to localize the volume of interest (VOI) and estimate the probability that a voxel belongs to the liver according its intensity. The probabilistic image would be used to initialize the 3D PAC model. Secondly, a new contour indicator function, which is a component of the model, is produced by combining the gradient-based edge detection and Hessian-matrix-based surface detection. Then, a fast numerical scheme derived for the 3D PAC model is performed to evolve the initial probabilistic image into the global minimizer of the model, which is a smoothed probabilistic image showing a distinctly highlighted liver. Next, a simple region-growing strategy is applied to extract the whole liver mask from the smoothed probabilistic image. Finally, a B-spline surface is constructed to fit the patch of the rib cage to prevent possible leakage into adjacent intercostal tissues. ResultsThe proposed method is evaluated on two public datasets. The average Dice score, volume overlap error, volume difference, symmetric surface distance and volume processing time are 0.96, 7.35%, 0.02%, 1.17 mm and 19.8 s for the Sliver07 dataset, and 0.95, 8.89%, -0.02%$-0.02\%$, 1.45 mm and 23.08 s for the 3Dircadb dataset, respectively. ConclusionsThe proposed fully-automatic approach can effectively segment the liver from low-contrast and complex backgrounds. The quantitative and qualitative results demonstrate that the proposed segmentation method outperforms state-of-the-art traditional automatic liver segmentation algorithms and achieves very competitive performance compared with recent deep leaning-based methods.
引用
收藏
页码:2100 / 2120
页数:21
相关论文
共 50 条
  • [1] Automatic 3D Segmentation of CT Images Based on Active Contour Models
    Jiang, Huiyan
    Cheng, Qingshui
    2009 11TH IEEE INTERNATIONAL CONFERENCE ON COMPUTER-AIDED DESIGN AND COMPUTER GRAPHICS, PROCEEDINGS, 2009, : 540 - +
  • [2] Active Contour Based Segmentation of 3D Surfaces
    Krueger, Matthias
    Delmas, Patrice
    Gimel'farb, Georgy
    COMPUTER VISION - ECCV 2008, PT II, PROCEEDINGS, 2008, 5303 : 350 - 363
  • [3] Fast Automatic Segmentation of the Esophagus from 3D CT Data Using a Probabilistic Model
    Feulner, Johannes
    Zhou, S. Kevin
    Cavallaro, Alexander
    Seifert, Sascha
    Hornegger, Joachim
    Comaniciu, Dorin
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2009, PT I, PROCEEDINGS, 2009, 5761 : 255 - +
  • [4] Automatic liver vessel segmentation using 3D region growing and hybrid active contour model
    Zeng, Ye-zhan
    Liao, Sheng-hui
    Tang, Ping
    Zhao, Yu-qian
    Liao, Miao
    Chen, Yan
    Liang, Yi-xiong
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 97 : 63 - 73
  • [5] Automatic 3D model-based method for liver segmentation in MRI based on active contours and total variation minimization
    Bereciartua, Arantza
    Picon, Artzai
    Galdran, Adrian
    Iriondo, Pedro
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 20 : 71 - 77
  • [6] Automatic segmentation and 3D reconstruction of human liver based on CT image
    Ai, Haiming
    Yang, Chunlan
    Wu, Shuicai
    Zeng, Yi
    Bo, Song
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [7] Automatic 3D coronary artery segmentation based on local region active contour model
    Chen, Xiaohong
    Jiang, Jufeng
    Zhang, Xiaofeng
    JOURNAL OF THORACIC DISEASE, 2024, 16 (04) : 2563 - 2579
  • [8] AUTOMATIC SEGMENTATION OF CT SCANS OF THE LIVER FOR 3D VISUALIZATION
    GAO, L
    KUSZYK, BS
    FISHMAN, EK
    RADIOLOGY, 1995, 197 : 328 - 328
  • [9] COMBINING ATLAS AND ACTIVE CONTOUR FOR AUTOMATIC 3D MEDICAL IMAGE SEGMENTATION
    Gao, Yi
    Tannenbaum, Allen
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 1401 - 1404
  • [10] Liver Segmentation in CT based on ResUNet with 3D Probabilistic and Geometric Post Process
    Xu, Wendong
    Liu, Hong
    Wang, Xiangdong
    Qian, Yueliang
    2019 IEEE 4TH INTERNATIONAL CONFERENCE ON SIGNAL AND IMAGE PROCESSING (ICSIP 2019), 2019, : 685 - 689