Osseointegration of titanium implants after surface treatment with ultraviolet light or cold atmospheric plasma in vivo

被引:0
|
作者
Henningsen, Anders [1 ,4 ]
Precht, Clarissa [2 ]
Karnatz, Nadia [3 ]
Bibiza, Eric [4 ]
Van, Ming [1 ]
Guo, Linna [5 ]
Gosau, Martin [4 ]
Smeets, Ralf [1 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Oral & Maxillofacial Surg, Div Regenerat Orofacial Med, Hamburg, Germany
[2] BG Trauma Hosp Berlin, Dept Craniomaxillofacial Surg, Berlin, Germany
[3] Univ Clin Dusseldorf, Dept Oral & Maxillofacial Surg, Dusseldorf, Germany
[4] Univ Med Ctr Hamburg Eppendorf, Dept Oral & Maxillofacial Surg, Martinistr 52, D-20246 Hamburg, Germany
[5] Cent South Univ, Xiangya Hosp 2, Dept Stomatol, Changsha, Peoples R China
关键词
dental implant; plasma gases; titanium; ultraviolet rays; DENTAL IMPLANTS; ARGON; PHOTOFUNCTIONALIZATION; ZIRCONIA; IMPACT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To determine the histological effects of ultraviolet light and cold atmospheric plasma treatment on the osseointegration of titanium implants in vivo.Materials and methods: Six juvenile pigs were divided into three groups of two animals each. A total of 54 titanium implants were placed randomly in the pigs' calvarial bone (nine implants per pig). Of these, 18 implants served as untreated controls. The remaining 36 implants served as the experimental group and were treated with either ultraviolet light or argon plasma for 12 minutes each prior to insertion. Two pigs in each group were kept until 2, 4 and 8 weeks and then sacrificed. Resonance frequency analysis was conducted after implant placement and at the time of sacrifice. Osseointegration was evaluated using microcomputed tomography scans and histomorphometrical analysis.Results: After initial loss, all implants showed a constant increase in implant stability quotient values over time without significant differences between the groups. The bone-implant contact values increased steadily for all implants over 8 weeks of healing. Surface-treated implants showed significantly higher bone-implant contact values compared to untreated implants at each time point. Bone area fraction occupancy values were almost always higher following both treatment methods; however, differences were only significant after 4 and 8 weeks for the cold atmospheric plasmaConclusions: Ultraviolet light and cold atmospheric plasma may improve histomorphometrical osseointegration of titanium implants significantly.
引用
收藏
页码:197 / 208
页数:12
相关论文
共 50 条
  • [1] Osseointegration of Zirconia Implants after UV-Light or Cold Atmospheric Plasma Surface Treatment In Vivo
    Krautwald, Lisa
    Smeets, Ralf
    Stolzer, Carolin
    Rutkowski, Rico
    Guo, Linna
    Reitmeier, Aline
    Gosau, Martin
    Henningsen, Anders
    MATERIALS, 2022, 15 (02)
  • [2] Osseointegration of Dental Implants after Vacuum Plasma Surface Treatment In Vivo
    Kahm, Se Hoon
    Lee, Sang Hwa
    Lim, Youbong
    Jeon, Hyun Jeong
    Yun, Kyoung-In
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (10)
  • [3] Efficacy of plasma treatment for surface cleansing and osseointegration of sandblasted and acid-etched titanium implants
    Bae, Gang-Ho
    Cho, Won-Tak
    Lee, Jong-Ho
    Huh, Jung-Bo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2024, 16 (03): : 189 - 199
  • [4] Effect of ultraviolet photofunctionalization of dental titanium implants on osseointegration
    Mehl, Christian
    Kern, Matthias
    Neumann, Friederike
    Baehr, Telse
    Wiltfang, Joerg
    Gassling, Volker
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2018, 19 (07): : 525 - 534
  • [5] Surface thermal oxidation on titanium implants to enhance osteogenic activity and in vivo osseointegration
    Wang, Guifang
    Li, Jinhua
    Lv, Kaige
    Zhang, Wenjie
    Ding, Xun
    Yang, Guangzheng
    Liu, Xuanyong
    Jiang, Xinquan
    SCIENTIFIC REPORTS, 2016, 6
  • [6] Surface thermal oxidation on titanium implants to enhance osteogenic activity and in vivo osseointegration
    Guifang Wang
    Jinhua Li
    Kaige Lv
    Wenjie Zhang
    Xun Ding
    Guangzheng Yang
    Xuanyong Liu
    Xinquan Jiang
    Scientific Reports, 6
  • [7] Osseointegration evaluation of plasma nitrided titanium implants
    Guerra Neto, C. L. B.
    da Silva, M. A. M.
    Alves, C., Jr.
    SURFACE ENGINEERING, 2009, 25 (06) : 434 - 439
  • [8] Osseointegration Properties of Titanium Implants Treated by Nonthermal Atmospheric-Pressure Nitrogen Plasma
    Yan, Sifan
    Komasa, Satoshi
    Agariguchi, Akinori
    Pezzotti, Giuseppe
    Okazaki, Joji
    Maekawa, Kenji
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (23)
  • [9] Osseointegration of atmospheric plasma-sprayed titanium implants: Influence of the native oxide layer
    Cunha, Alexandre
    Renz, Renata Pedrolli
    Blando, Eduardo
    de Oliveira, Rogerio Belle
    Huebler, Roberto
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (01) : 30 - 36
  • [10] Changes in surface characteristics of titanium and zirconia after surface treatment with ultraviolet light or non-thermal plasma
    Henningsen, Anders
    Smeets, Ralf
    Heuberger, Roman
    Jung, Ole T.
    Hanken, Henning
    Heiland, Max
    Cacaci, Claudio
    Precht, Clarissa
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2018, 126 (02) : 126 - 134