Management of glaucoma with Boston type 1 keratoprosthesis

被引:2
|
作者
Utine, Canan Asli [1 ,2 ]
Arikan, Gul [1 ]
Yardim, Elvan [1 ]
Gunenc, Uzeyir [1 ]
机构
[1] Dokuz Eylul Univ, Dept Ophthalmol, Izmir, Turkiye
[2] Izmir Biomed & Genome Ctr, Izmir, Turkiye
关键词
Glaucoma; surgery; Intraocular pressure; Postopera-tive complication; Prosthesis implantation; Glaucoma drainage implant; DRAINAGE IMPLANT; SURGERY; PROGRESSION; TONOMETRY; OUTCOMES;
D O I
10.5935/0004-2749.20230026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To describe the frequency, clinical characteristics, complications, and management of glaucoma in eyes that underwent keratoprosthesis implantation. Methods: Patients who underwent keratoprosthesis surgery between June 2010 and January 2020 were retrospectively evaluated for glaucoma association and prognoses. Results: Among 17 patients who underwent keratoprosthesis surgery, 9 (52.9%) were associated with underlying or keratoprosthesis-induced glaucoma. Five eyes (29.4%) had underlying glaucoma and underwent a glaucoma drainage device implantation at least 6 months before keratoprosthesis surgery. One eye (5.9%) with normal intraocular pressure had glaucoma drainage device implantation at the same session with keratoprosthesis surgery due to high-risk characteristics of anterior segment structures. Four eyes with preexisting glaucoma showed progression after keratoprosthesis surgery. Additional antiglaucomatous treatment was commenced in two eyes whereas implantation of 2nd glauco-ma drainage device was performed in two eyes. Postoperative complications in three eyes (100%) with glaucoma drainage device implanted 6 months before or at the same session with aphakic type keratoprosthesis surgery with partial vitrectomy included rhegmatogenous retinal detachment in two eyes and bacterial endophthalmitis in one eye. Migration of silicone oil through the tube to the subconjunctival area was seen after pars plana vitrectomy in one eye. None of the three eyes (0%) that underwent glaucoma drainage device implantation years before keratoprosthesis surgery experienced a posterior segment complication other than glaucomatous progression. Out of 11 eyes with no previous history of glaucoma, 3 (27.3%) showed high intraocular pressure and glaucomatous disc changes after keratoprosthesis surgery, which could be pharmacologically controlled. Conclusions: In this cohort, eyes with preexisting glaucoma were more difficult to manage compared to eyes with de novo glaucoma after keratoprosthesis surgery. Retinal complications appeared more often when glaucoma drainage device implantation was performed no more than 6 months before aphakic type keratoprosthesis surgery with partial vitrectomy.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [1] Management of glaucoma with Boston type 1 keratoprosthesis
    Bhambra, Nishaant
    Harissi-Dagher, Mona
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2022, 85 (05) : 540 - 542
  • [2] Innovative Approaches to Glaucoma Management of Boston Keratoprosthesis Type 1
    Thasarat S. Vajaranant
    Jessica Liu
    Jacob Wilensky
    M. Soledad Cortina
    Ahmad A. Aref
    Current Ophthalmology Reports, 2016, 4 (3) : 147 - 153
  • [3] Glaucoma Management in Patients With Aniridia and Boston Type 1 Keratoprosthesis
    Nascimento E Silva, Rafaella
    Shen, Lucy Q.
    Chiou, Carolina A.
    Shanbhag, Swapna S.
    Paschalis, Eleftherios I.
    Pasquale, Louis R.
    Colby, Kathryn A.
    Lman, Claes H. Doh
    Chodosh, James
    Alves, Milton R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 207 : 258 - 267
  • [4] Glaucoma management in Boston keratoprosthesis type I recipients
    Pho Nguyen
    Chopra, Vikas
    CURRENT OPINION IN OPHTHALMOLOGY, 2014, 25 (02) : 134 - 140
  • [5] Boston type 1 keratoprosthesis for primary congenital glaucoma
    Haugsdal, Jaclyn M.
    Goins, Kenneth M.
    Greiner, Mark A.
    Kwon, Young H.
    Alward, Wallace L. M.
    Wagoner, Michael D.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (03) : 328 - 331
  • [6] Improving glaucoma management for the Boston keratoprosthesis type 1: tubes versus lasers
    Geoffrion, Dominique
    Harissi-Dagher, Mona
    EXPERT REVIEW OF OPHTHALMOLOGY, 2020, 15 (06) : 313 - 320
  • [7] Challenges of Glaucoma Management in Patients with Type I Boston Keratoprosthesis
    AlHilali, Sara M.
    Al-Swailem, Samar A.
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 369 - 374
  • [8] Challenges in management of the Boston Keratoprosthesis Type 1
    Koo, Ellen H.
    Hannush, Sadeer B.
    CURRENT OPINION IN OPHTHALMOLOGY, 2021, 32 (04) : 385 - 388
  • [9] Cyclophotocoagulation in the Control of Glaucoma in Patients With the Boston Keratoprosthesis Type 1
    Jabbour, Samir
    Harissi-Dagher, Mona
    Agoumi, Younes
    Singh, Harmanjit
    Robert, Marie-Claude
    CORNEA, 2020, 39 (02) : 181 - 185
  • [10] Glaucoma Outcomes Following Boston Keratoprosthesis Type 1 Surgery
    Geoffrion, Dominique
    Harissi-Dagher, Mona
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)