Paired Comparison of Routine Molecular Screening of Patient Samples with Advanced Non-Small Cell Lung Cancer in Circulating Cell-Free DNA Using Three Targeted Assays

被引:1
|
作者
Barthelemy, David [1 ,2 ,3 ,4 ]
Lescuyer, Gaelle [2 ,3 ,4 ]
Geiguer, Florence [2 ,3 ,4 ]
Grolleau, Emmanuel [3 ,4 ,5 ,6 ]
Gauthier, Arnaud [2 ,7 ]
Balandier, Julie [2 ,3 ,4 ]
Raffin, Margaux [2 ,3 ,4 ]
Bardel, Claire [1 ,8 ]
Bouyssounouse, Bruno [9 ]
Rodriguez-Lafrasse, Claire [2 ,7 ]
Couraud, Sebastien [3 ,4 ,5 ,6 ]
Wozny, Anne-Sophie [2 ,7 ]
Payen, Lea [1 ,2 ,3 ,4 ]
机构
[1] Claude Bernard Lyon 1, Inst Pharmaceut & Biol Sci ISPB, F-69373 Lyon, France
[2] Hosp Civils Lyon, Lyon Sud Hosp, Dept Biochem & Mol Biol, F-69495 Pierre Benite, France
[3] Claude Bernard Univ Lyon I, Fac Med & Maieut Lyon Sud, Ctr Innovat Cancerol Lyon CICLY EA 3738, F-69921 Oullins, France
[4] Hosp Civils Lyon, Canc Inst, Circulating Canc CIRCAN Program, F-69495 Pierre Benite, France
[5] Claude Bernard Univ Lyon 1, Fac Med & Maieut Lyon Sud, F-69921 Oullins, France
[6] Hosp Civils Lyon, Lyon Sud Hosp, Pneumol Dept, Acute Resp Dis & Thorac Oncol, F-69495 Pierre Benite, France
[7] Claude Bernard Univ Lyon I, Fac Med & Maieut Lyon Sud, Cellular & Mol Radiobiol Lab UMR CNRS5822, IP2I, F-69921 Oullins, France
[8] Hosp Civils Lyon, Dept Bioinformat, F-69008 Lyon, France
[9] INOVOTION, F-38700 La Tronche, France
关键词
cfDNA; MRD; early stages; lung cancer; NSCLC; digital PCR; custom validated NGS assay; comparison of methods; performance; MUTATIONS; QUANTIFICATION;
D O I
10.3390/cancers15051574
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Circulating tumor DNA (ctDNA) samples reflect the total tumor burden and allow longitudinal monitoring of mutational sensitizing alterations in routine use for advanced non-small cell lung cancer (NSCLC). Various assays are developed at high sensitivity and specificity. To drive the choice of the best assay at diagnosis, we compared the clinical performance of an ultra-sensitive Plasma-SeqSensei (TM) SOLID CANCER IVD kit with the Plasma OncoBEAM (TM) EGFR V2 assay, or with our custom validated NGS routine assay. Global clinical concordances rates of 75% and 68% were found between the Plasma-SeqSensei (TM) SOLID CANCER IVD assay with the Plasma OncoBEAM (TM) EGFR V2 assay, and our custom validated NGS assays. The Plasma-SeqSensei (TM) SOLID CANCER IVD tool enables the identification of the maximum number of patients bearing sensitizing alterations for a tyrosine kinase inhibitor indication at diagnosis, while the custom NGS assay, with weaker clinical sensitivity, is dedicated to the exploration of resistance mechanisms and co-mutations during clinical progression. Introduction: Progressive advanced non-small cell lung cancer (NSCLC) accounts for about 80-85% of all lung cancers. Approximately 10-50% of patients with NSCLC harbor targetable activating mutations, such as in-frame deletions in Exon 19 (Ex19del) of EGFR. Currently, for patients with advanced NSCLC, testing for sensitizing mutations in EGFR is mandatory prior to the administration of tyrosine kinase inhibitors. Patients and Methods: Plasma was collected from patients with NSCLC. We carried out targeted NGS using the Plasma-SeqSensei (TM) SOLID CANCER IVD kit on cfDNA (circulating free DNA). Clinical concordance for plasma detection of known oncogenic drivers was reported. In a subset of cases, validation was carried out using an orthogonal OncoBEAM (TM) EGFR V2 assay, as well as with our custom validated NGS assay. Somatic alterations were filtered, removing somatic mutations attributable to clonal hematopoiesis for our custom validated NGS assay. Results: In the plasma samples, driver targetable mutations were studied, with a mutant allele frequency (MAF) ranging from 0.00% (negative detection) to 82.25%, using the targeted next-generation sequencing Plasma-SeqSensei (TM) SOLID CANCER IVD Kit. In comparison with the OncoBEAM (TM) EGFR V2 kit, the EGFR concordance is 89.16% (based on the common genomic regions). The sensitivity and specificity rates based on the genomic regions (EGFR exons 18, 19, 20, and 21) were 84.62% and 94.67%. Furthermore, the observed clinical genomic discordances were present in 25% of the samples: 5% in those linked to the lower of coverage of the OncoBEAM (TM) EGFR V2 kit, 7% in those induced by the sensitivity limit on the EGFR with the Plasma-SeqSensei (TM) SOLID CANCER IVD Kit, and 13% in the samples linked to the larger KRAS, PIK3CA, BRAF coverage of the Plasma-SeqSensei (TM) SOLID CANCER IVD kit. Most of these somatic alterations were cross validated in our orthogonal custom validated NGS assay, used in the routine management of patients. The concordance is 82.19% in the common genomic regions (EGFR exons 18, 19, 20, 21; KRAS exons 2, 3, 4; BRAF exons 11, 15; and PIK3CA exons 10, 21). The sensitivity and specificity rates were 89.38% and 76.12%, respectively. The 32% of genomic discordances were composed of 5% caused by the limit of coverage of the Plasma-SeqSensei (TM) SOLID CANCER IVD kit, 11% induced by the sensitivity limit of our custom validated NGS assay, and 16% linked to the additional oncodriver analysis, which is only covered by our custom validated NGS assay. Conclusions: The Plasma-SeqSensei (TM) SOLID CANCER IVD kit resulted in de novo detection of targetable oncogenic drivers and resistance alterations, with a high sensitivity and accuracy for low and high cfDNA inputs. Thus, this assay is a sensitive, robust, and accurate test.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Paired comparison of routine molecular screening of patient samples with advanced non-small cell lung cancer in circulating cell-free DNA using OncoBEAMTM EGFR V2, targeted next-generation sequencing Plasma-SeqSenseiTM Solid Cancer IVD Kit and custom-validated NGS assay
    Barthelemy, David
    Grolleau, Emmanuel
    Lescuyer, Gaelle
    Geiguer, Florence
    Gauthier, Arnaud
    Balandier, Julie
    Raffin, Margaux
    Bardel, Claire
    Bouyssounouse, Bruno
    Rodriguez-Lafrasse, Claire
    Couraud, Sebastien
    Wozny, Anne-Sophie
    Payen-Gay, Lea
    CANCER RESEARCH, 2023, 83 (07)
  • [2] Circulating cell-free DNA as a prognostic and predictive biomarker in non-small cell lung cancer
    Ai, Bo
    Liu, Huiquan
    Huang, Yu
    Peng, Ping
    ONCOTARGET, 2016, 7 (28) : 44583 - 44595
  • [3] Cell-free circulating tumor DNA in plasma/serum of non-small cell lung cancer
    Nie, Kun
    Jia, Yujie
    Zhang, Xuezhu
    TUMOR BIOLOGY, 2015, 36 (01) : 7 - 19
  • [4] The value of cell-free circulating tumour DNA profiling in advanced non-small cell lung cancer (NSCLC) management
    Maria Gabriela O. Fernandes
    Natália Cruz-Martins
    José Carlos Machado
    José Luís Costa
    Venceslau Hespanhol
    Cancer Cell International, 21
  • [5] The value of cell-free circulating tumour DNA profiling in advanced non-small cell lung cancer (NSCLC) management
    Fernandes, Maria Gabriela O.
    Cruz-Martins, Natalia
    Machado, Jose Carlos
    Costa, Jose Luis
    Hespanhol, Venceslau
    CANCER CELL INTERNATIONAL, 2021, 21 (01)
  • [6] Evaluating circulating cell-free DNA and DNA integrity index as biomarkers in non-small cell lung cancer
    Ezzeldin, Nada
    El-Lebedy, Dalia
    Hassan, Mirhane
    Shalaby, Alaa Omar
    Hussein, Sabah Ahmed Mohamed
    Gharib, Ahmed Mohamed
    Hamdy, Gehan
    Mohammed, Asmaa Mahmoud
    Ramadan, Abeer
    Sobeih, Mohamed Emam
    JOURNAL OF THE EGYPTIAN NATIONAL CANCER INSTITUTE, 2024, 36 (01)
  • [7] A quantitative analysis of the potential biomarkers of non-small cell lung cancer by circulating cell-free DNA
    Wei, Lirong
    Wu, Wangxi
    Han, Liming
    Yu, Weimo
    Du, Yuzhen
    ONCOLOGY LETTERS, 2018, 16 (04) : 4353 - 4360
  • [8] Clinical implications of circulating cell-free DNA quantification and metabolic tumor burden in advanced non-small cell lung cancer
    Hyun, Myung Han
    Lee, Eun Seong
    Eo, Jae Seon
    Kim, Sungeun
    Kang, Eun Joo
    Sung, Jae Sook
    Choi, Yoon Ji
    Park, Kyong Hwa
    Shin, Sang Won
    Lee, Sung Yong
    Kim, Yeul Hong
    LUNG CANCER, 2019, 134 : 158 - 166
  • [9] Cell-free circulating tumour DNA (ctDNA) in the management of patients with non-biopsiable advanced non-small cell lung cancer (NSCLC)
    Kushnir, M.
    Winter, H.
    Murias, C.
    Bains, P.
    Abbosh, C. Z.
    Papadatos-Pastos, D.
    Newsome-Davis, T.
    Ahmed, T.
    Swanton, C.
    Forster, M. D.
    Moore, D.
    Bennett, P.
    Faull, I.
    Lanman, R. B.
    Arkenau, H-T.
    ANNALS OF ONCOLOGY, 2018, 29
  • [10] Predictive factors for detectability of genomic alterations from circulating cell-free DNA in patients with advanced non-small cell lung cancer
    Kimura, H.
    Koba, H.
    Kasahara, K.
    ANNALS OF ONCOLOGY, 2017, 28