Colorimetric and fluorescent dual-mode pH sensor with PMIA as substrate and CQDs as probe for high accuracy detection of full range pH

被引:6
|
作者
Huo, Kefeng [1 ]
Zhang, Jifan [1 ]
Lin, Tao [1 ]
Zhang, Yiyun [1 ]
Liu, Yi [1 ]
Liu, Xunyong [1 ,2 ,3 ,4 ]
机构
[1] Ludong Univ, Sch Chem & Mat Sci, Yantai 264025, Shandong, Peoples R China
[2] Shangdong Lab Yantai Adv Mat & Green Manufacture, Yantai 264006, Shandong, Peoples R China
[3] Yantai Growth Drivers Convers Res Inst, Yantai 264000, Shandong, Peoples R China
[4] Yantai Sci & Technol Achievement Transfer & Transf, Yantai 264000, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Poly(m-phenylene isophthalamide); Carbon quantum dots; pH; Dual-mode; Colorimetric; Fluorescent; CARBON DOTS; EMISSION; POLYMER;
D O I
10.1016/j.dyepig.2023.111574
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The pH test is particularly important in many fields, such as chemical production and medical diagnosis. However, the most commonly used pH test strips for pH detection have disadvantages such as low strength, poor stability, only qualitative measurement and only a single-color response. Therefore, a dual-mode pH sensor prepared by a phase conversion method with Poly(m-phenylene isophthalamide) (PMIA) as the substrate and carbon quantum dots (CQDs) as probes was developed. This sensor is capable of producing dual changes in fluorescence color and fluorescence intensity over the full range of pH. The -COOH and -NH2 groups in CQDs can interact with the amide group in PMIA to make the sensor highly stable. Three correlations were established based on the fluorescence color and fluorescence intensity at different pH, which compensated the shortage of traditional pH test paper that could not be quantitatively detected. More importantly, the sensor can be used for pH detection in a wide range of water samples, and both colorimetric and fluorescence detection modes exhibit extremely high fit coefficients (R2 > 0.99) and short response times (similar to 5 s). Therefore, the dual-mode pH sensor provides an important solution for the development of pH detection devices with high stability and accuracy.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A dual-mode colorimetric/fluorescent probe based on perylene: Response to acidic pH values
    Yang, Liu
    Liu, Yan
    Li, Ping
    Liu, Yu-Long
    Liang, Xiao-Min
    Fu, Ying
    Ye, Fei
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2021, 129 : 97 - 103
  • [2] Yellow-green fluorescent carbon dots as fluorescent/colorimetric dual-mode probe for the detection of pH value and its application in fluorescent painting
    Yang, Yao
    Zhang, Shengrui
    Chinese Journal of Analysis Laboratory, 2022, 41 (09) : 1021 - 1024
  • [3] Covalent Organic Framework Functionalized with 8-Hydroxyquinoline as a Dual-Mode Fluorescent and Colorimetric pH Sensor
    Long Chen
    He, Linwei
    Ma, Fuyin
    Wei Liu
    Wang, Yaxing
    Silver, Mark A.
    Chen, Lanhua
    Lin Zhu
    Gui, Daxiang
    Juan Diwu
    Chai, Zhifang
    Wang, Shuao
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (18) : 15364 - 15368
  • [4] A dual-mode sensor for colorimetric and "turn-on" fluorescent detection of ascorbic acid
    Liu, Yinghua
    Wei, Zhenni
    Duan, Wenxiu
    Ren, Cuiling
    Wu, Jiang
    Liu, Dan
    Chen, Hongli
    DYES AND PIGMENTS, 2018, 149 : 491 - 497
  • [5] Fluoride detection with a colorimetric and fluorescent dual-mode chemosensor
    Song, Chanwoo
    Gil, Dongkyun
    Lee, Jae Jun
    Jung, Sumin
    Kim, Cheal
    COLORATION TECHNOLOGY, 2023, 139 (04) : 395 - 406
  • [6] Bridging biological and food monitoring: A colorimetric and fluorescent dual-mode sensor based on N-doped carbon dots for detection of pH and histamine
    Zhang, Xiaoran
    Wang, Jing
    Hasan, Elias
    Sun, Xincheng
    Asif, Muhammad
    Aziz, Ayesha
    Lu, Wenjing
    Dong, Chuan
    Shuang, Shaomin
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 470
  • [7] Colorimetric and Photothermal Dual-Mode Sensor for Detection of Histone
    Xue-Tao, Liu
    Xi-Ru, Sun
    Cheng-Hui, Liu
    Yu-Cong, Wang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (11) : 1756 - 1764
  • [8] A Dual-Mode Colorimetric/Fluorescent Sensor Comprising Rhodamine B and Piperazine: Response to Acidic pH Values and Investigation of Recognition Mechanism
    Wu, Fang-hui
    Luo, Xiang-rui
    Yang, Jun-qing
    Ren, Mei-juan
    Wei, Xian-wen
    Yan, Zhengquan
    CHEMISTRYSELECT, 2020, 5 (11): : 3138 - 3143
  • [9] An upconversion fluorescent and colorimetric dual-mode optical probe for triazophos pesticides
    Chen, Yinyin
    She, Xingying
    Wu, Wei
    Wang, Xianxiang
    MICROCHEMICAL JOURNAL, 2023, 193
  • [10] A hydrazone-linked covalent organic framework as a dual-mode colorimetric and fluorescence pH sensor
    Feng, Jing
    Hu, Changcheng
    Bai, Yuhongxu
    Su, Qing
    Liu, Shufang
    Li, Menghao
    Wang, Wen
    Ren, Hao
    Wu, Qiaolin
    MICROPOROUS AND MESOPOROUS MATERIALS, 2024, 366