Behavior and design of circular concrete columns strengthened with textile-reinforced mortar subjected to eccentric compression

被引:5
|
作者
Ran, Jinlin [1 ]
Li, Tingchun [1 ]
Wang, Hongshan [2 ]
Zhu, Qingwen [1 ]
Zhang, Hao [1 ]
Du, Yiteng [3 ]
Li, Weiteng [1 ]
机构
[1] Shandong Univ Sci & Technol, Coll Civil Engn & Architecture, Qingdao 266590, Peoples R China
[2] China Univ Petr, Sch Geosci, Qingdao 266580, Peoples R China
[3] Binzhou Univ, Dept Architectural Engn, Binzhou 256600, Peoples R China
基金
中国国家自然科学基金;
关键词
Circular cross-section; Concrete slender column; Textile layer; Eccentric compression; Bearing capacity calculation; STRESS-STRAIN RELATIONSHIP; FRP; FIBER; FRCM; COMPOSITE; LOAD; CONFINEMENT;
D O I
10.1016/j.istruc.2023.03.065
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Textile-reinforced mortar (TRM) is a cheaper and eco-friendlier material for the concrete confinement than steel and fiber-reinforced polymer (FRP). The behaviors of plain concrete slender columns with circular cross-section strengthened with TRM under eccentric compression were analyzed both experimentally and analytically in this paper. The test results showed that TRM could effectively inhibit the extension of cracks in columns, and increasing the number of textile layers from one to three led to a 44% increase in ultimate load. Meanwhile, the secondary moment of columns relative to the total moment varied from 20% to 35%, which was positively related to the confinement effectiveness of TRM. Then, a comparison of the behaviors of confined concrete columns under axial load-flexural moment (P-M) loading demonstrated that the confinement provided by TRM was relatively insufficient when compared to steel and FRP, behaving a post-peak softening phase of compressive constitutive curves. However, the textile with high tensile strength improved the stress distribution of cross-section of eccentrically loaded columns, thereby observing a much slower reduction in ultimate load with the increase of the eccentric ratio. Finally, according to a cross-section bearing capacity analysis, the procedure of analytical calculations was proposed to predict the ultimate load of TRM-confined concrete columns at a given eccentric ratio. Furthermore, the proposed analytical calculations provided a parametric study to reveal the correlation between the eccentric ratio and the number of textile layers, and then a simplified regression formula for design purpose was developed. This research highlights the behavior and design of concrete strengthened with TRM under P-M loading, which would give researchers and engineers an insight.
引用
收藏
页码:242 / 257
页数:16
相关论文
共 50 条
  • [1] Behavior and design of slender circular tubed-reinforced-concrete columns subjected to eccentric compression
    Zhou, Xuhong
    Liu, Jiepeng
    Wang, Xuanding
    Chen, Y. Frank
    [J]. ENGINEERING STRUCTURES, 2016, 124 : 17 - 28
  • [2] Behavior of textile-reinforced concrete columns
    dos Santos, Fernanda Cristinna Alonso
    Campos, Claudia Maria de Oliveira
    Cardoso, Daniel Carlos Taissum
    [J]. STRUCTURAL CONCRETE, 2024, 25 (02) : 1223 - 1240
  • [3] Behavior of short circular tubed-reinforced-concrete columns subjected to eccentric compression
    Wang, Xuanding
    Liu, Jiepeng
    Zhang, Sumei
    [J]. ENGINEERING STRUCTURES, 2015, 105 : 77 - 86
  • [4] Experimental Study of Flexural Behavior of Reinforced Concrete Beam Strengthened with Prestressed Textile-Reinforced Mortar
    Park, Jongho
    Park, Sun-Kyu
    Hong, Sungnam
    [J]. MATERIALS, 2020, 13 (05)
  • [5] Seismic behavior of textile-reinforced concrete-strengthened RC columns under different axial compression ratios
    Liu Ming
    Yin Shi-Ping
    Cong Xi
    [J]. JOURNAL OF ENGINEERED FIBERS AND FABRICS, 2019, 14
  • [6] Investigation on the Displacement Ductility Coefficient of Reinforced Concrete Columns Strengthened with Textile-Reinforced Concrete
    Wang, Boxue
    Yin, Shiping
    Liu, Ming
    [J]. ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [7] Experimental and numerical study on short eccentric columns strengthened by textile-reinforced concrete under sustaining load
    Liu, Dejun
    Huang, Hongwei
    Zuo, Jianping
    Duan, Kang
    Xue, Yadong
    Li, Yingjie
    [J]. JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2017, 36 (23) : 1712 - 1726
  • [8] Seismic performance of reinforced concrete columns retrofitted by textile-reinforced mortar jackets
    Dinh, Ngoc Hieu
    Park, Sung-ho
    Choi, Kyoung-Kyu
    [J]. Structure and Infrastructure Engineering, 2020, 16 (10): : 1364 - 1381
  • [9] Seismic performance of reinforced concrete columns retrofitted by textile-reinforced mortar jackets
    Dinh, Ngoc Hieu
    Park, Sung-ho
    Choi, Kyoung-Kyu
    [J]. STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2020, 16 (10) : 1364 - 1381
  • [10] Behavior and design of slender square tubed-reinforced-concrete columns subjected to eccentric compression
    Wang, Xuanding
    Liu, Jiepeng
    [J]. THIN-WALLED STRUCTURES, 2017, 120 : 153 - 160