摘要
Irradiated materials impose unique challenges when it comes to sample preparation for transmission electron microscopy (TEM) analysis. After the preparation of TEM samples by electrolytic polish, Ar ion milling was usually used to remove the surface contamination, as well as to thin the samples to desired thickness. Therefore, it is necessary to evaluate the advantages and limitations of Ar ion milling technique. In this work, the optimum milling condition with minimal surface artifacts was determined by Ar ion milling with various incident angles and beam energies, and the high-resolution TEM (HR-TEM) examinations confirmed the optimum condition to be 4.0keV Ar ions with incident angles of +/- 4 degrees. In addition, Ar ion milling and subsequent thickness measurement by energy-filtered TEM (EF-TEM) were conducted to determine the thinning rate. It is found that electrolytic polished TEM lamella has a wedge-shape structure with a very sharp edge, and the thinning rates varied from 9.7 +/- 1.4nm/minute to 5.0 +/- 2.3nm/minute across the TEM lamella for 4.0keV Ar ions. However, the thinning rates for 2keV and 1keV Ar ions were under the examination limit, and they were supposed not sufficient to thin the tungsten samples. Even though the exact thinning rate varies for different materials, the general trends for the Ar ion milling observed in this study can be used as a guidance.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] TEM sample preparation by ion milling amorphization
    Barna, A
    Pécz, B
    Menyhard, M
    MICRON, 1999, 30 (03) : 267 - 276
  • [2] Energy-filtered TEM with the integrated imaging filter
    Nadarzinski, K
    de Jong, AF
    Kundmann, MK
    Kothleitner, G
    ELECTRON MICROSCOPY 1998, VOL 1: GENERAL INTEREST AND INSTRUMENTATION, 1998, : 243 - 244
  • [3] Evaluation of neon focused ion beam milling for TEM sample preparation
    Pekin, T. C.
    Allen, F. I.
    Minor, A. M.
    JOURNAL OF MICROSCOPY, 2016, 264 (01) : 59 - 63
  • [4] Energy-filtered imaging on a 300kV TEM
    Bentley, J
    Kenik, EA
    Evans, ND
    Hall, EL
    Zinkle, SJ
    ELECTRON MICROSCOPY AND ANALYSIS 1995, 1995, 147 : 187 - 190
  • [5] Preface to the special issue on energy-filtered TEM imaging
    Hofer, F
    Egerton, R
    MICRON, 1997, 28 (05) : 331 - 331
  • [6] Modified theory of contrast formation in energy-filtered TEM
    Angert, I
    Jahn, W
    Holmes, KC
    Schroder, RR
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 95 - 95
  • [7] Optimized Ar+-ion milling procedure for TEM cross-section sample preparation
    Dieterle, Levin
    Butz, Benjamin
    Mueller, Erich
    ULTRAMICROSCOPY, 2011, 111 (11) : 1636 - 1644
  • [8] Energy-filtered TEM of Ag-Co thin films
    Scott, JHJ
    Majetich, SA
    POLYCRYSTALLINE THIN FILMS: STRUCTURE, TEXTURE, PROPERTIES, AND APPLICATIONS II, 1996, 403 : 731 - 736
  • [9] Enhanced TEM Sample Preparation Using In-situ Low Energy Argon Ion Milling
    Stegmann, Heiko
    Ritz, Yvonne
    Utess, Dirk
    Huebner, Rene
    Zschech, Ehrenfried
    FRONTIERS OF CHARACTERIZATION AND METROLOGY FOR NANOELECTRONICS: 2009, 2009, 1173 : 275 - +
  • [10] Chemical mapping of DNA and counter-ion content inside phage by energy-filtered TEM
    Pernilla Nevsten
    Alex Evilevitch
    Reine Wallenberg
    Journal of Biological Physics, 2012, 38 : 229 - 240