Unanticipated difficult airway after prolonged use of a laryngeal mask airway

被引:0
|
作者
Lorente, Claudia [1 ]
Kiss, Edgar [1 ]
Kastner, Galit [1 ]
Dariya, Vedanta Singh [2 ]
Olomu, Patrick [1 ]
Szmuk, Peter [1 ,3 ]
机构
[1] Univ Texas Southwestern Med Ctr, Dept Anesthesiol & Pain Management, Div Anesthesiol, Childrens Hlth Syst Texas, Dallas, TX 75390 USA
[2] Univ Texas Southwestern Med Ctr, Dept Pediat, Div Neonatol, Childrens Hlth Syst Texas, Dallas, TX USA
[3] Outcome Res Consortium, Cleveland, OH USA
关键词
airway edema; airway management; infant; laryngeal masks; newborn; pediatric difficult airway; pharyngeal edema;
D O I
10.1111/pan.14813
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The laryngeal mask airway (LMA) is recognized as a safe alternative to endotracheal intubation for short-term airway maintenance. In this case report we present the case of a term neonate with upper airway obstruction which was managed with a deflated LMA for 7 consecutive days. Despite previous reports of extended LMA use in neonates without complications, this patient experienced significant pharyngeal mucosal injury and edema, leading to difficulty with subsequent intubation attempts.