Rapid prediction of MRI-induced RF heating of active implantable medical devices using machine learning

被引:0
|
作者
Vu, Jasmine [1 ,2 ]
Sanpitak, Pia [2 ]
Bhusal, Bhumi [2 ]
Jiang, Fuchang [1 ,2 ]
Golestanirad, Laleh [1 ,2 ]
机构
[1] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Evanston, IL 60208 USA
[2] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL 60208 USA
来源
2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC | 2023年
关键词
SIMULATION; LEADS; SAR;
D O I
10.1109/EMBC40787.2023.10340900
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The interaction between an active implantable medical device and magnetic resonance imaging (MRI) radiofrequency (RF) fields can cause excessive tissue heating. Existing methods for predicting RF heating in the presence of an implant rely on either extensive phantom experiments or electromagnetic (EM) simulations with varying degrees of approximation of the MR environment, the patient, or the implant. On the contrary, fast MR thermometry techniques can provide a reliable real-time map of temperature rise in the tissue in the vicinity of conductive implants. In this proof-of-concept study, we examined whether a machine learning (ML) based model could predict the temperature increase in the tissue near the tip of an implanted lead after several minutes of RF exposure based on only a few seconds of experimentally measured temperature values. We performed phantom experiments with a commercial deep brain stimulation (DBS) system to train a fully connected feedforward neural network (NN) to predict temperature rise after similar to 3 minutes of scanning at a 3 T scanner using only data from the first 5 seconds. The NN effectively predicted Delta T-max-R-2 = 0.99 for predictions in the test dataset. Our model also showed potential in predicting RF heating for other various scenarios, including a DBS system at a different field strength (1.5 T MRI, R-2 = 0.87), different field polarization (1.2 T vertical MRI, R-2 = 0.79), and an unseen implant (cardiac leads at 1.5 T MRI, R-2 = 0.91). Our results indicate great potential for the application of ML in combination with fast MR thermometry techniques for rapid prediction of RF heating for implants in various MR environments.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] A technique for the reduction of RF-induced heating of active implantable medical devices during MRI
    Wang, Yu
    Zheng, Jianfeng
    Guo, Ran
    Wang, Qingyan
    Kainz, Wolfgang
    Long, Stuart
    Chen, Ji
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 349 - 364
  • [2] Prediction of MRI RF-induced Heating for Passive Implantable Medical Devices Using Convolutional Neural Network
    Lan, Qianlong
    Zheng, Jianfeng
    Chen, Ji
    Zhang, Mingchi
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND SIGNAL & POWER INTEGRITY VIRTUAL SYMPOSIUM(IEEE EMC+SIPI), 2020, : 270 - 275
  • [3] Effects of Strain Relief Loop on MRI RF-Induced Heating of Active Implantable Medical Devices
    Akter, Mir Khadiza
    Guo, Ran
    Islam, Md Zahidul
    Zheng, Jianfeng
    Chen, Ji
    PROCEEDINGS OF THE 2022 IEEE TEXAS SYMPOSIUM ON WIRELESS AND MICROWAVE CIRCUITS AND SYSTEMS (WMCS), 2022,
  • [4] Fast Prediction of MRI RF-induced Heating For Implantable Plate Devices Using Neural Network
    Zheng, Jianfeng
    Yang, Rui
    Chen, Ji
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 1011 - 1012
  • [5] RF-induced heating for active implantable medical devices in dual parallel leads configurations at 1.5 T MRI
    Hu, Wei
    Guo, Ran
    Wang, Qingyan
    Zheng, Jianfeng
    Tsang, Jeffrey
    Kainz, Wolfgang
    Long, Stuart
    Chen, Ji
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (02) : 686 - 698
  • [6] Electrode Sensitivity for MRI-RF Induced Heating Evaluation of Active Implantable Medical Device
    Long, Tiangang
    Jiang, Changqing
    Li, Luming
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 67 - 69
  • [7] Effect of Strain Relief Loop Position on the RF-Induced Heating of Active Implantable Medical Devices at 1.5-T MRI
    Akter, Mir Khadiza
    Guo, Ran
    Islam, Md Zahidul
    Zheng, Jianfeng
    Kainz, Wolfgang
    Long, Stuart A.
    Chen, Ji
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2024, 66 (04) : 1041 - 1056
  • [8] A Transmission Line Model for the Evaluation of MRI RF-Induced Fields on Active Implantable Medical Devices
    Liu, Jingshen
    Zheng, Jianfeng
    Wang, Qingyan
    Kainz, Wolfgang
    Chen, Ji
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2018, 66 (09) : 4271 - 4281
  • [9] RF Safety of Active Implantable Medical Devices
    Silemek, Berk
    Acikel, Volkan
    Atalar, Ergin
    EMAGRES, 2019, 8 (02): : 103 - 119
  • [10] MRI RF-Induced Heating Prediction of Complex-Shaped Passive Implantable Medical Devices Using Mesh-Based Convolutional Neural Network
    Chang, Jiajun
    Lan, Qianlong
    Guo, Ran
    Zheng, Jianfeng
    Romero, Rebeca
    Kainz, Wolfgang
    Long, Stuart A. A.
    Chen, Ji
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2023, 71 (05) : 2207 - 2214