Enhancing Whole-Brain Magnetic Field Homogeneity for 3D-Magnetic Resonance Spectroscopic Imaging with a Novel Unified Coil: A Preliminary Study

被引:1
|
作者
Malagi, Archana Vadiraj [1 ]
Li, Xinqi [1 ]
Zhang, Na [1 ]
Liu, Yucen [1 ]
Huang, Yuheng [1 ,2 ]
Serry, Fardad Michael [1 ]
Long, Ziyang [1 ,2 ,3 ]
Yang, Chia-Chi [1 ]
Shan, Yujie [1 ]
Cai, Yubin [1 ]
Zepeda, Jeremy [1 ]
Binesh, Nader [4 ]
Li, Debiao [1 ,2 ]
Yang, Hsin-Jung [1 ]
Han, Hui [3 ]
机构
[1] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA 90095 USA
[3] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10065 USA
[4] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
基金
美国国家卫生研究院;
关键词
3T; magnetic resonance spectroscopic imaging; shim-RF head coils; array coils; local B-0 shimming; spherical harmonic (SH); PARALLEL RECEPTION; WATER SUPPRESSION; MOTION CORRECTION; MR SPECTROSCOPY; ORDER; RESOLUTION; CORTEX; TUMORS;
D O I
10.3390/cancers16061233
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The spectral quality of magnetic resonance spectroscopic imaging (MRSI) can be affected by strong magnetic field inhomogeneities, posing a challenge for 3D-MRSI's widespread clinical use with standard scanner-equipped 2nd-order shim coils. To overcome this, we designed an empirical unified shim-RF head coil (32-ch RF receive and 51-ch shim) for 3D-MRSI improvement. We compared its shimming performance and 3D-MRSI brain coverages against the standard scanner shim (2nd-order spherical harmonic (SH) shim coils) and integrated parallel reception, excitation, and shimming (iPRES) 32-ch AC/DC head coil. We also simulated a theoretical 3rd-, 4th-, and 5th-order SH shim as a benchmark to assess the UNIfied shim-RF coil (UNIC) improvements. In this preliminary study, the whole-brain coverage was simulated by using B0 field maps of twenty-four healthy human subjects (n = 24). Our results demonstrated that UNIC substantially improves brain field homogeneity, reducing whole-brain frequency standard deviations by 27% compared to the standard 2nd-order scanner shim and 17% compared to the iPRES shim. Moreover, UNIC enhances whole-brain coverage of 3D-MRSI by up to 34% compared to the standard 2nd-order scanner shim and up to 13% compared to the iPRES shim. UNIC markedly increases coverage in the prefrontal cortex by 147% and 47% and in the medial temporal lobe and temporal pole by 29% and 13%, respectively, at voxel resolutions of 1.4 cc and 0.09 cc for 3D-MRSI. Furthermore, UNIC effectively reduces variations in shim quality and brain coverage among different subjects compared to scanner shim and iPRES shim. Anticipated advancements in higher-order shimming (beyond 6th order) are expected via optimized designs using dimensionality reduction methods.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A Full Brain 3D-Magnetic Resonance Spectroscopic Imaging Study of Migraine and Post-Traumatic Headache
    Nikolova, Simona
    Schwedt, Todd J.
    Zhou, Yuxiang
    Chong, Brian W.
    Dumkrieger, Gina
    Chong, Catherine D.
    NEUROTRAUMA REPORTS, 2024, 5 (01): : 1060 - 1068
  • [2] Whole-brain magnetic resonance spectroscopic imaging measures are related to disability in ALS
    Stagg, Charlotte J.
    Knight, Steven
    Talbot, Kevin
    Jenkinson, Mark
    Maudsley, Andrew A.
    Turner, Martin R.
    NEUROLOGY, 2013, 80 (07) : 610 - 615
  • [3] Rapid Whole-Brain Magnetic Resonance Imaging With Isotropic Resolution at 3 Tesla
    Edelman, Robert R.
    Dunkle, Eugene
    Koktzoglou, Ioannis
    Griffin, Andrew
    Russell, Eric J.
    Ankenbrandt, William
    Ragin, Ann
    Carrillo, Andres
    INVESTIGATIVE RADIOLOGY, 2009, 44 (01) : 54 - 59
  • [4] Fast 3D magnetic resonance fingerprinting for a whole-brain coverage
    Ma, Dan
    Jiang, Yun
    Chen, Yong
    McGivney, Debra
    Mehta, Bhairav
    Gulani, Vikas
    Griswold, Mark
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 2190 - 2197
  • [5] Manual dexterity and brain structure in patients with schizophrenia: A whole-brain magnetic resonance imaging study
    Hidese, Shinsuke
    Ota, Miho
    Sasayama, Daimei
    Matsuo, Junko
    Ishida, Ikki
    Hiraishi, Moeko
    Teraishi, Toshiya
    Hattori, Kotaro
    Kunugi, Hiroshi
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2018, 276 : 9 - 14
  • [6] 3D whole-brain vessel wall cardiovascular magnetic resonance imaging: a study on the reliability in the quantification of intracranial vessel dimensions
    Zhang, Na
    Zhang, Fan
    Deng, Zixin
    Yang, Qi
    Diniz, Marcio A.
    Song, Shlee S.
    Schlick, Konrad H.
    Maya, M. Marcel
    Gonzalez, Nestor
    Li, Debiao
    Zheng, Hairong
    Liu, Xin
    Fan, Zhaoyang
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [7] 3D whole-brain vessel wall cardiovascular magnetic resonance imaging: a study on the reliability in the quantification of intracranial vessel dimensions
    Na Zhang
    Fan Zhang
    Zixin Deng
    Qi Yang
    Marcio A. Diniz
    Shlee S. Song
    Konrad H. Schlick
    M. Marcel Maya
    Nestor Gonzalez
    Debiao Li
    Hairong Zheng
    Xin Liu
    Zhaoyang Fan
    Journal of Cardiovascular Magnetic Resonance, 20
  • [8] Fast Sub-Millimeter Whole-Brain Magnetic Resonance Imaging of Novel Biomarkers for Multiple Sclerosis
    Sati, Pascal
    Patil, Sunil
    Krueger, Gunnar
    Derbyshire, John A.
    Reich, Daniel S.
    MULTIPLE SCLEROSIS JOURNAL, 2019, 25 : 12 - 13
  • [9] Delineation of recurrent glioblastoma by whole brain spectroscopic magnetic resonance imaging
    Bell, Jonathan B. B.
    Jin, William
    Goryawala, Mohammed Z. Z.
    Azzam, Gregory A. A.
    Abramowitz, Matthew C. C.
    Diwanji, Tejan
    Ivan, Michael E. E.
    del Pilar Guillermo Prieto Eibl, Maria
    de la Fuente, Macarena I. I.
    Mellon, Eric A. A.
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [10] Age-related Brain Metabolic Changes up to Seventh Decade in Healthy Humans Whole-brain Magnetic Resonance Spectroscopic Imaging Study
    Maghsudi, Helen
    Schuetze, Martin
    Maudsley, Andrew A.
    Dadak, Mete
    Lanfermann, Heinrich
    Ding, Xiao-Qi
    CLINICAL NEURORADIOLOGY, 2020, 30 (03) : 581 - 589