Experimental investigation of water vapor condensation from flue gas in different rows of a heat exchanger model

被引:1
|
作者
Poskas, Robertas [1 ]
Sirvydas, Arunas [1 ]
Mingilaite, Laura [2 ]
Jouhara, Hussam [3 ]
Poskas, Povilas [1 ]
机构
[1] Lithuanian Energy Inst, Nucl Engn Lab, Breslaujos 3, LT-44403 Kaunas, Lithuania
[2] Kaunas Univ Technol, Fac Mech Engn & Design, Dept Energy, Studentu 56, LT-51424 Kaunas, Lithuania
[3] Brunel Univ London, Coll Engn Design & Phys Sci, Heat Pipe & Thermal Management Res Grp, Uxbridge UB8 3PH, England
基金
欧盟地平线“2020”;
关键词
Biofuel flue gas; Water vapor condensation; Vertical tubes bundle; Crossflow; Different rows heat transfer; Condensate mass along HE; FORCED-CONVECTION CONDENSATION; STEAM; TUBE; BUNDLE; BANK;
D O I
10.1016/j.tsep.2023.102365
中图分类号
O414.1 [热力学];
学科分类号
摘要
Condensing heat exchangers (HE) are used in many applications because of their usability with different fluids and a wide operating range in terms of pressure, temperature and power. Despite that, the thermal design of condensing heat exchangers is still not optimized, due to the complexity of the condensation process and lack of related research. This paper presents results of experimental investigations of biofuel flue gas water vapor condensation on vertical tubes in different rows of a tube bundle in a crossflow. The effects of water vapor mass fraction, inlet flue gas temperature and the Reynolds number on heat transfer when the inlet cooling water temperature and flow rate are constant were analyzed. The results obtained showed that the main parameters which had the most influence on the condensation process were the water vapor mass fraction in the flue gas and its temperature at the inlet to the test section. In the range of inlet flue gas Reynolds numbers investigated, the Re effect on heat transfer was not as significant as the effect of the parameters indicated above. However, the Re number had some influence on the heat transfer variation along the inline tube bundle. A comparison of the average Nu number in the case of dry air with the experimentally determined average Nu number, even with low condensable gas mass fraction (6 %), showed that it increased considerably. A correlation was proposed, which helps to determine the average Nu number for the heat exchanger in the range of experiments performed.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Numerical and experimental investigation on water vapor condensation in turbulent flue gas
    Li, Kai
    Wang, Enlu
    Li, Deli
    Husnain, Naveed
    Fareed, Shagufta
    [J]. APPLIED THERMAL ENGINEERING, 2019, 160
  • [2] Simultaneous heat and water recovery from flue gas by membrane condensation: Experimental investigation
    Zhao, Shuaifei
    Yan, Shuiping
    Wang, David K.
    Wei, Yibin
    Qi, Hong
    Wu, Tao
    Feron, Paul H. M.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 113 : 843 - 850
  • [3] An Experimental Investigation of Water Vapor Condensation from Biofuel Flue Gas in a Model of Condenser, (2) Local Heat Transfer in a Calorimetric Tube with Water Injection
    Poskas, Robertas
    Sirvydas, Arunas
    Kulkovas, Vladislavas
    Jouhara, Hussam
    Poskas, Povilas
    Miliauskas, Gintautas
    Puida, Egidijus
    [J]. PROCESSES, 2021, 9 (08)
  • [4] Experimental investigation of humidified air condensation in different rows of serpantine heat exchanger - Cooling water flow rate effect
    Poskas, Robertas
    Sirvydas, Arunas
    Salem, Mohab
    Poskas, Povilas
    Jouhara, Hussam
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 54
  • [5] Experimental investigation of water vapor condensation from hot humidified air in serpentine heat exchanger
    Poskas, R.
    Sirvydas, A.
    Salem, M.
    Poskas, P.
    Jouhara, H.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 221
  • [6] Experimental investigation on flue gas condensation heat recovery system integrated with heat pump and spray heat exchanger
    Zhang, Qunli
    Liu, Tao
    Cheng, Xuanrui
    Guo, Shuaifei
    Zhang, Lin
    Lu, Xiaoshu
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 49
  • [7] An Experimental Investigation of Water Vapor Condensation from Biofuel Flue Gas in a Model of Condenser, (1) Base Case: Local Heat Transfer without Water Injection
    Poskas, Robertas
    Sirvydas, Arunas
    Kulkovas, Vladislavas
    Poskas, Povilas
    [J]. PROCESSES, 2021, 9 (05)
  • [8] Investigation of effect of cooling water characteristics on flue gas condensation along vertical tube heat exchanger
    Poskas, Robertas
    Sirvydas, Arunas
    Mingilaite, Laura
    Poskas, Povilas
    Jouhara, Hussam
    [J]. ENERGY, 2024, 289
  • [9] Heat Transfer in Flue Gas with Vapor Condensation
    贾力
    彭晓峰
    [J]. Tsinghua Science and Technology, 2002, (02) : 177 - 181
  • [10] The experimental research on water vapor condensation of wet flue gas in a vertical tube
    Jia, L
    Li, XP
    Sun, JD
    [J]. ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 481 - 484