Dynamic assessment of brain perfusion in a middle cerebral artery occlusion rat model by contrast-enhanced ultrasound imaging: a pilot study

被引:0
|
作者
Zhou, Chenyun [1 ,3 ]
Zhu, Xiaoxia [1 ]
Li, Jin [2 ]
Luo, Yan [1 ]
Zhou, Yuqing [1 ]
机构
[1] Sichuan Univ, Dept Ultrasound, West China Hosp, Chengdu, Sichuan, Peoples R China
[2] Sichuan Univ, Dept Neurosurg, West China Hosp, Chengdu, Sichuan, Peoples R China
[3] Sichuan Univ, Dept Ultrasound, West China Hosp, 37 Guoxue St, Chengdu 610041, Sichuan, Peoples R China
关键词
Middle cerebral artery occlusion; contrast-enhanced ultrasound; brain perfusion; ischemic infarction; collateral compensation; ANIMAL-MODELS; COLLATERAL FLOW; ISCHEMIC-STROKE; REPERFUSION; CRANIECTOMY; MISMATCH; TISSUE; TIME;
D O I
10.1177/02841851231205163
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The middle cerebral artery occlusion model (MCAo) is a commonly used animal model for cerebral ischemia studies but lacks accessible imaging techniques for the assessment of hemodynamic changes of the model. Purpose: The study aims to explore the value of contrast-enhanced ultrasound (CEUS) in evaluating brain perfusion in the early stages after MCAo surgery. Material and Methods: In total, 18 adult male Sprague-Dawley rats were subjected to right MCAo using an intraluminal filament model, and CEUS was performed at the three following timepoints: before (T0), immediately after (T1), and 6 h after permanent MCAo (T2). Twelve rats successfully completed the study, and their brains were removed and stained using 2, 3, 5-triphenyltetrazolium chloride (TTC). CEUS video images were visualized offline, and the time-intensity curves (TICs) were analyzed. Different cerebrovascular patterns and manifestations of the contrast enhancement in rat ischemic hemispheres were observed. Semi-quantitative parameters of TICs in ischemic areas (ROIi) and the surrounding normal- or hypo-perfused areas (ROIn) were calculated and compared between T0, T1, and T2, and also between ROIi and ROIn. Results: A significant correlation was found between the lesion volume (%) determined by TTC and CEUS parameters (r = -0.691, P = 0.013 for peak intensity; r = -0.742, P = 0.006 for area under the curve) at T2. After the same occlusion, there were differences in contrast perfusion in each group. Conclusion: This study suggests that CEUS could be an effective imaging tool for studying cerebral ischemia and perfusion in small animals as long as the transcranial acoustic window allows it.
引用
收藏
页码:3042 / 3051
页数:10
相关论文
共 50 条
  • [1] Dynamic Contrast-Enhanced Perfusion MR Imaging With SPIO A Pilot Study
    Amemiya, Shiori
    Akahane, Masaaki
    Aoki, Shigeki
    Abe, Osamu
    Kamada, Kyosuke
    Saito, Nobuyuki
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2009, 44 (09) : 503 - 508
  • [2] CONTRAST-ENHANCED ULTRASOUND IMAGING IN DETECTION OF CHANGES IN CEREBRAL PERFUSION
    Bilotta, Federico
    Robba, Chiara
    Santoro, Antonio
    Delfini, Roberto
    Rosa, Giovanni
    Agati, Luciano
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (11): : 2708 - 2716
  • [3] Assessment of Blood-Brain Barrier Permeability by Dynamic Contrast-Enhanced MRI in Transient Middle Cerebral Artery Occlusion Model after Localized Brain Cooling in Rats
    Kim, Eun Soo
    Lee, Seung-Koo
    Kwon, Mi Jung
    Lee, Phil Hye
    Ju, Young-Su
    Yoon, Dae Young
    Kim, Hye Jeong
    Lee, Kwan Seop
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (05) : 715 - 724
  • [4] Mapping the dynamics of brain perfusion using functional ultrasound in a rat model of transient middle cerebral artery occlusion
    Brunner, Clement
    Isabel, Clothilde
    Martin, Abraham
    Dussaux, Clara
    Savoye, Anne
    Emmrich, Julius
    Montaldo, Gabriel
    Mas, Jean-Louis
    Baron, Jean-Claude
    Urban, Alan
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (01): : 263 - 276
  • [5] High-Framerate Dynamic Contrast-Enhanced Ultrasound Imaging of Rat Kidney Perfusion
    Le, David Q.
    Chang, Emily
    Dayton, Paul A.
    Johnson, Kennita
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1326 - 1329
  • [6] In Vivo Transcranial Imaging of Blood Perfusion in Rat Brain Using Contrast-enhanced Ultrasound
    Du, Juan
    Liu, Dalong
    Ebbini, Emad S.
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [7] Dynamic Perfusion Assessment by Contrast-Enhanced Ultrasound in Blood-Brain Barrier Disruption
    Lin, Wun-Hao
    Fan, Ching-Hsiang
    Ting, Chien-Yu
    Liu, Hao-Li
    Yeh, Chih-Kuang
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1152 - 1155
  • [8] Contrast-enhanced ultrasound cerebral perfusion measurement
    Roth, S
    Aronson, S
    Erickson, R
    Park, S
    Fernandez, A
    STROKE, 1996, 27 (04) : 800 - 800
  • [9] Intestinal perfusion measurements with contrast-enhanced ultrasound and dynamic contrast-enhanced magnetic resonance imaging enterography: A comparison study
    Wilkens, R.
    Peters, D. A.
    Nielsen, A. H.
    Hovgaard, V. P.
    Glerup, H.
    Krogh, K.
    JOURNAL OF CROHNS & COLITIS, 2016, 10 : S164 - S165
  • [10] Evaluation of cerebral perfusion by contrast-enhanced ultrasound at low mechanical index in cerebral ischemia rat model
    Wang, Xiaolei
    Liu, Bo
    Liu, Jiongou
    Sun, Aitong
    Cui, Yan
    Xiao, Rui
    Li, Chunyang
    INTERNATIONAL ANGIOLOGY, 2017, 36 (06) : 545 - 552