Post-Fire Behavior and Repair of Fire-Damaged RC Columns Using Composite Jackets

被引:1
|
作者
Belakhdar, Ahmed Rafik [1 ]
Dimia, Mohamed Salah [2 ]
Baghdadi, Mohamed [2 ]
Bouderradji, Meriem [2 ]
Gherabli, Soumia [2 ]
Alaoui, Nail [3 ]
机构
[1] Larbi Tebessi Univ, Civil Engn Dept, Min Lab, Tebessa 12002, Algeria
[2] Univ Batna 2, Dept Civil Engn, Fac Technol, Batna 05078, Algeria
[3] Univ ZIANE Achour Djelfa, Lab Rech Modelisat Simulat & Optimisat Syst Comple, Djelfa 17000, Algeria
来源
关键词
reinforced concrete column; fire damage; post-fire strengthening; composite jacket; numerical; investigation; SAFIR; CONCRETE COLUMNS; COMPRESSIVE STRENGTH; STEEL TUBES; PERFORMANCE; EXPOSURE; CONFINEMENT; CAPACITY; MODEL;
D O I
10.18280/acsm.470407
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Reinforced concrete (RC) structures are frequently employed in construction owing to their versatility, strength, and durability. However, these structures can be vulnerable to fire incidents, which can significantly compromise their structural integrity and load carrying capacity. In the aftermath of a fire, damaged RC columns often necessitate rehabilitation to restore their strength and functionality. The present study intends to carry out a numerical investigation of the behavior of reinforced concrete (RC) columns after their exposure to fire. As a first step, the study examined the effects of exposing the columns to fire for different periods (15, 30, 60 and 90 minutes) on the column's residual load-bearing capacity by considering some decisive geometrical parameters such as the column height and its cross-sectional area. The second step consisted of investigating the effectiveness of the strengthening techniques utilized by adding reinforcement and incorporating composite jackets, where each method used three external concrete compressive strength values, 25, 30, and 40 MPa, in order to improve the post-fire behavior of these columns. The results showed that the longer the column is exposed to fire, the lower its bearing capacity. However, it was also found that increasing the column cross-sectional area can reduce the percentage of load-bearing capacity. Moreover, A simple equation with sufficient accuracy has been proposed to predict the bearing capacity of reinforced columns. Finally, it was revealed that the strengthening methods used herein allowed restoring the capacity of the columns exposed to fire, but the strengthening technique using a composite jacket with steel plates showed better results in terms of strength. Where this technique allowed, it restored the capacity of the columns exposed to fire for a period of one hour by up to 182%.
引用
收藏
页码:247 / 257
页数:11
相关论文
共 50 条
  • [1] Study of fire-damaged circular RC columns repaired using composite confinement techniques
    Hussain, Iqrar
    Yaqub, Muhammad
    Mortazavi, Mina
    Ehsan, Muhammad Adeel
    Hussain, Mudasir
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2022, 177 (03) : 222 - 234
  • [2] Repair of fire-damaged reinforced concrete columns
    Lin, Chien-Hung
    Chen, Shun-Tyan
    Yang, Chen-An
    ACI Materials Journal, 1995, 92 (04) : 406 - 411
  • [3] Post-fire analysis and numerical modeling of a fire-damaged concrete bridge
    Timilsina, Santosh
    Yazdani, Nur
    Beneberu, Eyosias
    ENGINEERING STRUCTURES, 2021, 244
  • [4] Impact of time after fire on post-fire seismic behavior of RC columns
    Demir, Ugur
    Goksu, Caglar
    Binbir, Ergun
    Ilki, Alper
    STRUCTURES, 2020, 26 : 537 - 548
  • [5] REPAIR OF FIRE-DAMAGED REINFORCED-CONCRETE COLUMNS
    LIN, CH
    CHEN, ST
    YANG, CA
    ACI STRUCTURAL JOURNAL, 1995, 92 (04) : 406 - 411
  • [6] Repair of fire-damaged RC square columns with CFRP textile-reinforced ECC matrix
    Liu, Wang-Wei
    Ouyang, Li-Jun
    Gao, Wan-Yang
    Liang, Jian
    Wang, Tian-Ci
    Song, Jiang
    Yang, Jian
    ENGINEERING STRUCTURES, 2023, 292
  • [7] Repair of fire-damaged columns using self-compacting concrete with polypropylene fibres exposed to fire
    Fang, I-Kuang, 1600, Chinese Institute of Civil and Hydraulic Engineering (26):
  • [8] Effects of post-fire curing conditions on the restoration of material properties of fire-damaged concrete
    Park, Sun-Jong
    Yim, Hong Jae
    Kwak, Hyo-Gyoung
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 99 : 90 - 98
  • [9] Post-fire Seismic Behavior of RC Columns Built with Sustainable Concrete
    Demir, Ugur
    Unal, Goktug
    Goksu, Caglar
    Saribas, Ilyas
    Ilki, Alper
    JOURNAL OF EARTHQUAKE ENGINEERING, 2022, 26 (13) : 6869 - 6892
  • [10] A REVIEW ON REPAIR OF FIRE-DAMAGED CONCRETE COLUMNS WITH FIBRE REINFORCED POLYMER
    Jayaprakash, J.
    Zuki, Sharifah Salwa Mohd
    Keong, Choong Kok
    STRUCTURAL ANALYSIS OF HISTORICAL CONSTRUCTIONS, VOLS 1-3, 2012, : 953 - 960