Monte-Carlo Based Numerical Dosimetry in Reverberation Chamber Exposure Systems Employed for in-Vivo Rodent Bioassays

被引:3
|
作者
De Santis, Valerio [1 ]
Di Francesco, Antonio [2 ]
Foster, Kenneth R. [3 ]
Bit-Babik, Giorgi [4 ]
Faraone, Antonio [4 ]
机构
[1] Univ Aquila, Dept Ind & Informat Engn & Econ, I-67100 Laquila, Italy
[2] Univ Aquila, Dept Informat Engn Comp Sci & Math, I-67100 LAquila, Italy
[3] Univ Penn, Dept Bioengn, Philadelphia, PA 19041 USA
[4] Motorola Solut Inc, Ft Lauderdale, FL 33301 USA
关键词
Reverberation chambers; Rodents; Time-domain analysis; Rayleigh channels; Monte Carlo methods; Finite difference methods; Specific absorption rate; Dosimetry; in-vivo bioassay; reverberation chamber; specific absorption rate (SAR); ELECTROMAGNETIC-FIELDS; RATS; MICE;
D O I
10.1109/ACCESS.2023.3251889
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A Monte-Carlo based computational approach for the statistical characterization of the whole-body specific absorption rate (wbSAR) variability in large cohorts of rodents exposed to radio-frequency (RF) energy in reverberation chambers (RCs) is applied to adult male rat exposures illustrative of those in a US National Toxicology Program (NTP) cancer bioassay. A large number of 3D electromagnetic field realizations fulfilling Rayleigh fading properties were generated within an electrically-large volume representative of an ideal RC, yielding granular wbSAR distributions for an ensemble of 96 homogeneous rodent models with random mass distribution, postures, positions and orientations. Two case studies were addressed: a "momentary exposure " with each rat fixed in posture, position and orientation, and a "day-long exposure " in which the position, orientation and posture were varied randomly for each subsequent Rayleigh field realization. Over 500 and 2500 field realizations or "snapshots ", respectively, the rats' instantaneous wbSARs, as well as their individual time-averaged wbSARs, were found to be well fit by lognormal distributions. The large variability in instantaneous wbSARs in the cohort was due in part to the inherent Rayleigh field variability in RCs (70-80%) and in part to weight, posture and position variations (20-30%), while the effect of cage location was found to be small over day-long exposures. Averaging the exposure over field realizations substantially reduces the range of wbSARs in the cohort. Hence, when RF-induced thermal effects are studied, the relevant exposure metric (wbSAR averaged over appropriate times) features a narrower range than instantaneous wbSAR, which is the relevant metric in studies dealing with non-thermal effects. Compared to previous studies, the present approach was found to be computationally more efficient enabling thus a Monte-Carlo analysis by varying concurrently the incident field and the animals posture, position, and orientation. In practice, it can inform the choice of wbSAR targets in rodent bioassay, allowing to identify possible dose-effect trends while avoiding undue thermal stress.
引用
收藏
页码:22018 / 22033
页数:16
相关论文
共 5 条
  • [1] DEVELOPMENT OF A METHOD FOR CALIBRATING IN-VIVO MEASUREMENT SYSTEMS USING MAGNETIC-RESONANCE-IMAGING AND MONTE-CARLO COMPUTATIONS
    MALLETT, MW
    HICKMAN, DP
    KRUCHTEN, DA
    POSTON, JW
    HEALTH PHYSICS, 1995, 68 (06): : 773 - 785
  • [2] An Epid-based Monte Carlo Approach to In-Vivo Dosimetry for Intensity-Modulated Radiation Therapy Treatments
    Atwal, P. S.
    Shahine, B.
    Thomas, S.
    Cao, F.
    Rameseshan, R.
    MEDICAL PHYSICS, 2009, 36 (09) : 4320 - 4320
  • [3] A phantom-based experimental and Monte Carlo study of the suitability of in-vivo diodes and TLD for entrance in-vivo dosimetry in small-to-medium sized 6 MV photon fields
    Ketabi, Ali
    Karbasi, Sareh
    Faghihi, Reza
    Mosleh-Shirazi, Mohammad Amin
    RADIATION PHYSICS AND CHEMISTRY, 2022, 201
  • [4] MONTE-CARLO MODELING OF NEUTRON DEPTH-DOSE DISTRIBUTIONS IN OPTIMIZING PROMPT GAMMA IN-VIVO NEUTRON-ACTIVATION ANALYSIS SYSTEMS
    UTTERIDGE, TD
    RALSTON, AC
    WALLACE, SA
    ALLEN, BJ
    BEDDOE, AH
    APPLIED RADIATION AND ISOTOPES, 1994, 45 (07) : 789 - 794
  • [5] Are Gold-Palladium Nanoparticles Vesicles Equivalent to Proton and 4He Ion in Cellular Dosimetry: A Monte-Carlo Study Based On Ex Vivo Imaging
    Ma, Y.
    Laprise-Peletier, M.
    Lagueux, J.
    Cote, M.
    Fortin, M.
    Beaulieu, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E558 - E558