Dosimetric Comparison of 3D Conformal Radiotherapy (3D-CRT), Intensity-Modulated Radiotherapy (IMRT), and Volumetric-Modulated Arc Therapy (VMAT) in Cardiac-Sparing Whole Lung Irradiation

被引:0
|
作者
Yamauchi, Ryohei [1 ]
Akiyama, Shinobu [1 ]
Mizuno, Norifumi [1 ]
Kobayashi, Takako [1 ]
Itazawa, Tomoko [1 ]
Masuda, Tomoyuki [1 ]
Hirano, Miki [1 ]
Tomita, Fumihiro [1 ]
Hosoya, Yosuke [2 ]
Kawamori, Jiro [1 ]
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, Tokyo, Japan
[2] St Lukes Int Hosp, Dept Pediat, Tokyo, Japan
关键词
intensity-modulated radiation therapy (imrt); dosimetric comparison study; volumetric-modulated arc therapy; lung metastasis; respiratory motion; whole lung irradiation (wli); ewing sarcoma (es); PULMONARY METASTASES; WILMS-TUMOR;
D O I
10.7759/cureus.51047
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Whole lung irradiation (WLI) is used for the treatment of lung metastasis in Wilms tumor and Ewing sarcoma; however, cardiac complications are one of the concerns. We report the dosimetric advantages of WLI using volumetric -modulated arc therapy (VMAT) and present a dosimetric comparison of VMAT with anteroposterior-posteroanterior (AP -PA) and static -field intensity -modulated radiation therapy (IMRT). Additionally, we evaluated the dosimetric impact of respiratory motion and intra-fractional motion during VMAT treatment. Methods Seven patients were recruited in this study. AP -PA, IMRT, one-isocenter (1 -IC) VMAT, and 2 -IC VMAT were planned on the maximum inspiration and expiration CT, respectively. The prescribed dose was 15 Gy in 10 fractions. To determine the effects of respiratory motion, the CT series was replaced and the dose was evaluated while maintaining the beam information. To determine the effect of patient motion, perturbed dose calculations were performed using a two -IC VMAT. The perturbation doses were calculated by shifting only the IC of the one side beam by 3 mm or 5 mm in the right -to -left (RL) direction. Results The mean heart dose was 1467.0 cGy, 790.0 cGy, 764.2 cGy, and 738.4 cGy for AP -PA, IMRT, 1 -IC VMAT, and 2 -IC VMAT, respectively. When the expiration CT plan was recalculated with inspiration CT, Dmax increased approximately by 8%. In the 2 -IC VMAT plan, the D50%, D98%, and D2% dose differences were within +/- 2%, even with a 5 mm IC shift. Conclusion We confirmed a significant dosimetric advantage of VMAT over other techniques. 2 -IC VMAT should be considered an effective treatment option during irradiation for large target volumes.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] VOLUMETRIC MODULATED ARC THERAPY (VMAT) FOR DELIVERY OF PROSTATE RADIOTHERAPY: COMPARISON WITH INTENSITY MODULATED RADIOTHERAPY (IMRT) AND 3-DIMENSIONAL CONFORMAL RADIOTHERAPY (3D-CRT)
    Palma, D.
    Vollans, E.
    James, K.
    Nakano, S.
    Moiseenko, V.
    Shaffer, R.
    McKenzie, M.
    Morris, J.
    Otto, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S10 - S11
  • [2] Dosimetric Study Comparing 3D Conformal Radiotherapy (3D-CRT), Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) in Hypofractionated One-Week Radiotherapy Regimen in Breast Cancer
    Ahmad, Aftab
    Das, Saikat
    Kharade, Vipin
    Gupta, Manish
    Pandey, V. P.
    Anju, K. V.
    Balasubramanian, Ilamparithi
    Pasricha, Rajesh K.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [3] OPTIMIZATION OF RADIOTHERAPY TECHNIQUE IN APICAL LUNG TUMOUR: A COMPARATIVE STUDY OF 3D CONFORMAL RADIOTHERAPY (3D CRT) WITH INTENSITY MODULATED RADIOTHERAPY (IMRT) AND VOLUMETRIC MODULATED ARC THERAPY (VMAT)
    Martin, C.
    Harrowven, J.
    Fitchett, R.
    Ajithkumar, T. V.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S561 - S561
  • [4] Dosimetric comparison of 3-dimensional conformal radiotherapy (3D-CRT) and volumetric-modulated arc therapy (VMAT) in locally advanced cancer cervix
    Agrawal, Animesh
    Hadi, Rahat
    Rath, Satyajeet
    Bharati, Avinav
    Rastogi, Madhup
    Khurana, Rohini
    Sahni, Kamal
    Sapru, Shantanu
    Gandhi, Ajeet Kumar
    Srivastava, Anoop Kumar
    Mishra, Surendra Prasad
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 60 - 67
  • [5] Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)
    Wang, Xin
    Li, Guangjun
    Zhang, Yingjie
    Bai, Sen
    Xu, Feng
    Wei, Yuquan
    Gong, Youling
    [J]. MEDICAL DOSIMETRY, 2013, 38 (04) : 395 - 400
  • [6] DOSIMETRIC COMPARISON OF VOLUMETRIC INTENSITY-MODULATED ARC (RAPIDARC) THERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D CONFORMAL RADIOTHERAPY FOR PRIMARY LIVER TUMOURS
    John, Jacob
    Sivasevan, Roshni
    Sudha, Arun Sankar
    Sivanandan, Choondal Devan
    Abdurahman, Sajeed
    Paramu, Raghukumar
    Sreedevi, Shaiju Vasudevan
    George, Preethi Sara
    Jayaprakash, Puthuveettil Govindan
    [J]. EUROPEAN JOURNAL OF CANCER, 2015, 51 : E34 - E34
  • [7] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Samir, Fady
    Meaz, Talaat M.
    Hussiny, Fathi AEl
    Ahmed, Ahmed A.
    Mahmoud, Amr A.
    Refaat, Tamer
    Gawish, Ahmed
    Abouegylah, Mohamed
    [J]. JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (09) : 6239 - 6246
  • [8] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Fady Samir
    Talaat M. Meaz
    Fathi AEl Hussiny
    Ahmed A. Ahmed
    Amr A. Mahmoud
    Tamer Refaat
    Ahmed Gawish
    Mohamed Abouegylah
    [J]. Journal of Cancer Research and Clinical Oncology, 2023, 149 : 6239 - 6246
  • [9] Intensity-modulated proton therapy, volumetric-modulated arc therapy, and 3D conformal radiotherapy in anaplastic astrocytoma and glioblastoma
    Adeberg, S.
    Harrabil, S. B.
    Bougatf, N.
    Bernhardt, D.
    Rieber, J.
    Koerber, S. A.
    Syed, M.
    Sprave, T.
    Mohr, A.
    Abdollahi, A.
    Haberer, T.
    Combs, S. E.
    Herfarth, K.
    Debus, J.
    Rieken, S.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (11) : 770 - 779
  • [10] A dosimetric comparison: Intensity Modulated Proton Therapy (IMPT), Volumetric Modulated Arc Therapy (VMAT) and Three-Dimensional Conformal Radiotherapy (3D-CRT) for anaplastic astrocytoma and glioblastoma
    Adeberg, S.
    Harrabi, S. B.
    Bougatf, N.
    Tonndorf-Martini, E.
    Bernhardt, D.
    Rieber, J.
    Koerber, S.
    Mohr, A.
    Haberer, T.
    Herfarth, K.
    Debus, J.
    Rieken, S.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 : 127 - 127