Provision of Ramp-rate Limitation as Ancillary Service from Distribution to Transmission System: Definitions and Methodologies for Control and Sizing of Central Battery Energy Storage System

被引:1
|
作者
Gkavanoudis, Spyros I. [1 ]
Malamaki, Kyriaki-Nefeli D. [1 ]
Kontis, Eleftherios O. [1 ]
Demoulias, Charis S. [1 ]
Shekhar, Aditya [2 ]
Mushtaq, Umer [2 ]
Venu, Sagar Bandi [3 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Elect & Comp Engn, Thessaloniki, Greece
[2] Delft Univ Technol, Elect Engn Math & Comp Sci Dept, Delft, Netherlands
[3] FENECON Gmbh, Deggendorf, Germany
关键词
Battery energy storage system; distributed renewable energy resource; sizing; distribution system; transmission system; ramp-rate limitation; state of charge; POWER; CAPACITY; WIND;
D O I
10.35833/MPCE.2022.000595
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The variability of the output power of distributed renewable energy sources (DRESs) that originate from the fast-changing climatic conditions can negatively affect the grid stability. Therefore, grid operators have incorporated ramp-rate limitations (RRLs) for the injected DRES power in the grid codes. As the DRES penetration levels increase, the mitigation of high-power ramps is no longer considered as a system support function but rather an ancillary service (AS). Energy storage systems (ESSs) coordinated by RR control algorithms are often applied to mitigate these power fluctuations. However, no unified definition of active power ramps, which is essential to treat the RRL as AS, currently exists. This paper assesses the various definitions for ramp-rate RR and proposes RRL method control for a central battery ESS (BESS) in distribution systems (DSs). The ultimate objective is to restrain high-power ramps at the distribution transformer level so that RRL can be traded as AS to the upstream transmission system (TS). The proposed control is based on the direct control of the.P/.t, which means that the control parameters are directly correlated with the RR requirements included in the grid codes. In addition, a novel method for restoring the state of charge (SoC) within a specific range following a high ramp-up/down event is proposed. Finally, a parametric method for estimating the sizing of central BESSs (BESS sizing for short) is developed. The BESS sizing is determined by considering the RR requirements, the DRES units, and the load mix of the examined DS. The BESS sizing is directly related to the constant RR achieved using the proposed control. Finally, the proposed methodologies are validated through simulations in MATLAB/Simulink and laboratory tests in a commercially available BESS.
引用
收藏
页码:1507 / 1518
页数:12
相关论文
共 10 条
  • [1] Provision of Ramp-rate Limitation as Ancillary Service from Distribution to Transmission System: Definitions and Methodologies for Control and Sizing of Central Battery Energy Storage System
    Spyros I.Gkavanoudis
    Kyriaki-Nefeli D.Malamaki
    Eleftherios O.Kontis
    Aditya Shekhar
    Umer Mushtaq
    Sagar Bandi Venu
    Charis S.Demoulias
    [J]. Journal of Modern Power Systems and Clean Energy, 2023, 11 (05) : 1507 - 1518
  • [2] Adaptive Ramp-Rate Control of Hybrid Energy Storage System for PV Application
    Wu, Xiangqiang
    Tang, Zhongting
    Kerekes, Tamas
    [J]. 2022 IEEE 13TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2022,
  • [3] Provision of ramp-rate limitation from distribution networks to transmission systems as preventive action towards frequency disturbances
    Malamaki, Kyriaki-Nefeli D.
    Fotellis, Fotis
    Kontis, Eleftherios O.
    Gkontoras, Dimitrios
    Demoulias, Charis S.
    [J]. SUSTAINABLE ENERGY GRIDS & NETWORKS, 2023, 36
  • [4] Provision of inertial response as ancillary service from active distribution networks to the transmission system
    del Nozal, Alvaro Rodriguez
    Kontis, Eleftherios O.
    Mauricio, Juan M.
    Demoulias, Charis S.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (22) : 5123 - 5134
  • [5] Hybrid Energy Storage System in Standalone DC Microgrid with Ramp Rate Limitation for Extending the Lifespan of Battery
    Wongdet, Pinit
    Marungsri, Boonruang
    [J]. 2018 6TH INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON), 2018,
  • [6] SOC Management Algorithm of Battery Energy Storage System for PV Ramp Rate Control
    Kim, Nam-Kyu
    Cha, Hee-Jun
    Seo, Jae-Jin
    Won, Dong-Jun
    [J]. 2017 6TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY (IYCE), 2017,
  • [7] Provision of Primary Frequency Response as Ancillary Service From Active Distribution Networks to the Transmission System
    Kontis, Eleftherios O.
    Nozal, Alvaro Rodriguez del
    Mauricio, Juan M.
    Demoulias, Charis S.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (06) : 4971 - 4982
  • [8] Control Strategies and Economic Analysis of an LTO Battery Energy Storage System for AGC Ancillary Service
    Sun, Bingxiang
    He, Xitian
    Zhang, Weige
    Li, Yangxi
    Gong, Minming
    Yang, Yang
    Su, Xiaojia
    Zhu, Zhenlin
    Gao, Wenzhong
    [J]. ENERGIES, 2020, 13 (02)
  • [9] Ramp-rate control for power quality improvement of renewable grid-integrated microgrid with hybrid energy storage system
    Kumar, G. V. Brahmendra
    Palanisamy, K.
    De Tuglie, Enrico
    [J]. FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [10] Siting and Sizing of Energy Storage Systems: Towards a Unified Approach for Transmission and Distribution System Operators for Reserve Provision and Grid Support
    Massucco, Stefano
    Pongiglione, Paola
    Silvestro, Federico
    Paolone, Mario
    Sossan, Fabrizio
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2021, 190