Effect of elastic deformation on lubrication characteristics in different clearances and head size of metallic artificial hip joint

被引:0
|
作者
Suri, Mohd Syafiq Mohd [1 ]
Yusof, Ab Aziz Mohd [2 ]
Syahrom, Ardiyansyah [1 ,3 ]
Abd Latif, Mohd Juzaila [4 ]
Harun, Muhamad Noor [1 ,5 ]
机构
[1] Univ Teknol Malaysia UTM, Fac Mech Engn, Skudai, Johor, Malaysia
[2] Univ Teknol MARA UiTM, Fac Mech Engn, Masai, Johor, Malaysia
[3] Univ Teknol Malaysia UTM, Med Devices & Technol Ctr MEDITEC, Skudai, Johor, Malaysia
[4] Univ Tekn Malaysia Melaka UTeM, Fac Mech Engn, Durian Runtuh, Melaka, Malaysia
[5] Univ Teknol Malaysia UTM, Fac Mech Engn, Skudai 81310, Johor, Malaysia
关键词
Fluid characteristics; elastohydrodynamic lubrication; metallic artificial hip joint; fluid-structure interaction; SQUEEZE-FILM LUBRICATION; ON-METAL; ELASTOHYDRODYNAMIC LUBRICATION; CONTACT MECHANICS; WEAR; REPLACEMENTS; IMPLANT; HARD; PREDICTION; THICKNESS;
D O I
10.1177/09544062241233926
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The issue of lubrication in metallic artificial hip joints is discussed to prevent the two bearing surfaces from contacting each other. This study aims to analyse the characteristics of elastohydrodynamic lubrication (EHL) and investigate the effect of radial clearance and head size on the tribological performance of metallic artificial hip joints under steady-state conditions using the Fluid-Structure-Interaction (FSI) method. The average load in the z-direction and flexion-extension motion around the y-axis were used to represent normal walking. This study demonstrates that the film thickness profile from the validation study aligns with the findings of the previous study. The contour of the fluid pressure in the central contact zone changes with different time steps - the direction of fluid movement corresponds to the solid-fluid reaction. Additionally, the deformation of the cup surfaces contributes to the continuous fluid film that separates the contact surfaces. Furthermore, design parameters also influence EHL performance. It has been discovered that less radial clearance and a larger head size led to an increase in fluid film thickness.
引用
收藏
页码:7375 / 7387
页数:13
相关论文
共 15 条
  • [1] The effect of femoral component head size on posterior dislocation of the artificial hip joint
    Bartz, RL
    Noble, PC
    Kadakia, NR
    Tullos, HS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09): : 1300 - 1307
  • [2] The Effect of Femoral Head Size on The Cement Mantle in The Layered Artificial Hip Joint
    Annanto, Gilar Pandu
    Jamari
    Saputro, Eko
    Bayuseno, Athanasius Priharyoto
    Ismail, Rifky
    Tauviqirrahman, Mohammad
    Anwar, Iwan Budiwan
    EXPLORING RESOURCES, PROCESS AND DESIGN FOR SUSTAINABLE URBAN DEVELOPMENT, 2019, 2114
  • [3] Prediction of elastic deformation of acetabular cups and femoral heads for lubrication analysis of artificial hip joints
    Wang, FC
    Jin, ZM
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2004, 218 (J3) : 201 - 209
  • [4] Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
    Jin, ZM
    Dowson, D
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) : 247 - 256
  • [5] Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
    Jin, Z.M.
    Dowson, D.
    Fisher, J.
    Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1997, 211 (H3): : 247 - 256
  • [6] Analysis of fluid film lubrication in artificial hip joint replacements with surfaces of high elastic modulus
    University of Bradford, Department of Mechanical and Manufacturing Engineering, United Kingdom
    不详
    Proc. Inst. Mech. Eng. Part H J. Eng. Med., 3 (247-256):
  • [7] Effect of Fomoral Head Shape on Mechanical Behaviours of Artificial Hip Joint
    Han, Shuyang
    Ge, Shirong
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 1166 - 1170
  • [8] Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints
    Braunstein, Volker
    Sprecher, Christoph M.
    Wimmer, Markus A.
    Milz, Stefan
    Taeger, Georg
    ACTA ORTHOPAEDICA, 2009, 80 (03) : 283 - 290
  • [9] The effect of variable size posterior wall acetabular fractures on contact characteristics of the hip joint
    Olson, SA
    Bay, BK
    Pollak, AN
    Sharkey, NA
    Lee, T
    JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (06) : 395 - 402
  • [10] Curative effect of artificial femoral head replacement and its effect on hip joint function and complications of senile patients with femoral intertrochanteric fracture
    Shi, Haiwei
    Xiao, Long
    Wang, Zhifang
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 16 (02) : 623 - 628