Sensitivity analysis of operating parameters of proton exchange membrane fuel cells

被引:1
|
作者
Liu, Fei [1 ,2 ,3 ]
Li, Xichao [1 ,2 ,3 ]
Zhao, Peiwen [1 ,2 ,3 ]
Sun, Xianwei [1 ,2 ,3 ]
Zhao, Jingxiang [1 ,2 ,3 ]
Shen, Jun [4 ]
Dai, Zuoqiang [1 ,2 ,3 ]
Zheng, Lili [1 ,2 ,3 ]
机构
[1] Qingdao Univ, Coll Mech & Elect Engn, Qingdao 266071, Peoples R China
[2] Qingdao Univ, Engn Technol Ctr Power Integrat & Energy Storage, Qingdao 266071, Peoples R China
[3] Natl & Local Joint Engn Technol Ctr Intelligent P, Qingdao 266071, Peoples R China
[4] Hydra Power Qingdao Energy Technol Co Ltd, Qingdao 266100, Peoples R China
关键词
Fuel cells; Relative humidity; Stoichiometric ratio; Intake pressure; Operating temperature; Sensitivity; PEMFC; MODEL;
D O I
10.1007/s11581-023-05180-y
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The sensitivity of the operating parameters of proton exchange membrane fuel cells is essential to improve the performance and water management capabilities of the stack. The current research on proton exchange membrane fuel cell sensitivity is mainly focused on simulations and experimental methods for small activation area single cells, but less research literature for commercial stack with larger effective area. In this work, a commercial stack with an effective area of 300 cm2 membrane electrode is as the research object. The polarization curves under different operating conditions are obtained by experiment, and the voltage data are processed with first-order derivatives to systematically analyze the effects of gas relative humidity, stoichiometric ratio, inlet gas pressure and operating temperature on the performance of the stack. It was found that a certain degree of cathode inlet relative humidity, cathode stoichiometry ratio, in inlet pressure and in temperature are beneficial to the stack performance and are closely related to stack water management. However, with the cathode gas relative humidity reaching 45%, the cathode stoichiometry ratio increasing to 1.9 and the operating temperature increasing to 76 degrees C, the stack performance does not improve significantly. And the excessive increase in operating parameters is likely to have a negative impact on the stack performance. The stack performance is less sensitive to the anode stoichiometry ratio and anode gas relative humidity, and when the anode stoichiometry ratio is lower than 1.3, it will have a great negative impact on the stack performance. These are important for the development of controlling the operating parameters for commercial fuel cell.
引用
收藏
页码:5431 / 5440
页数:10
相关论文
共 50 条
  • [1] Sensitivity analysis of operating parameters of proton exchange membrane fuel cells
    Fei Liu
    Xichao Li
    Peiwen Zhao
    Xianwei Sun
    Jingxiang Zhao
    Jun Shen
    Zuoqiang Dai
    Lili Zheng
    Ionics, 2023, 29 : 5431 - 5440
  • [2] Sensitivity analysis of operating parameters for proton exchange membrane fuel cells
    Yang Z.-R.
    Li Y.
    Ji X.-F.
    Liu F.
    Hao D.
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2022, 52 (09): : 1971 - 1981
  • [3] Analysis of proton exchange membrane fuel cells voltage drops for different operating parameters
    Benmouiza, Khalil
    Cheknane, Ali
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (06) : 3512 - 3519
  • [4] The effects of operating parameters on the performance of proton exchange membrane fuel cells
    Dehsara, M.
    Kermani, M. J.
    MECHANIKA, 2013, (06): : 649 - 656
  • [5] Assessment of Sensitivity to Evaluate the Impact of Operating Parameters on Stability and Performance in Proton Exchange Membrane Fuel Cells
    Pan, Mingzhang
    Pan, Chengjie
    Liao, Jinyang
    Li, Chao
    Huang, Rong
    Wang, Qiwei
    ENERGIES, 2021, 14 (14)
  • [6] Sensitivity analysis of the modeling parameters used in simulation of proton exchange membrane fuel cells
    Corrêa, JM
    Farret, FA
    Popov, VA
    Simoes, MG
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (01) : 211 - 218
  • [7] Sensitivity analysis of operating parameters on a 65 kW proton exchange membrane fuel cell stack performances
    Ji, Xuefeng
    Wang, Xiaobing
    Li, Yan
    Guo, Jianqiang
    Yang, Zirong
    Hao, Dong
    ENERGY REPORTS, 2022, 8 : 521 - 527
  • [8] Sensitivity analysis and optimization of operating conditions of proton exchange membrane fuel cell
    Liao, Xiangrong
    Photong, Chonlatee
    Su, Jianbin
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (11) : 2505 - 2518
  • [9] Effects of operating parameters on the current density distribution in proton exchange membrane fuel cells
    Zhang, Y.
    Mawardi, A.
    Pitchumani, R.
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2006, 3 (04): : 464 - 476
  • [10] Sensitivity Analysis of the Impedance Characteristics of Proton Exchange Membrane Fuel Cells
    Niya, S. M. Rezaei
    Phillips, R. K.
    Hoorfar, M.
    FUEL CELLS, 2016, 16 (05) : 547 - 556