Thermodynamic Performance of a Cogeneration Plant Driven by Waste Heat from Cement Kilns Exhaust Gases

被引:3
|
作者
Mungyeko Bisulandu, Baby-Jean Robert [1 ,2 ]
Ilinca, Adrian [3 ]
Tsimba Mboko, Marcel [4 ]
Mbozi Mbozi, Lucien [4 ]
机构
[1] Univ Quebec Rimouski UQAR, Lab Rech Energie Eolienne LREE, 300 Allee Ursulines, Rimouski, PQ G5L 3A1, Canada
[2] Univ Kongo, Futuris Res Inst InReF, Inst Rech Futuris, OEFC & Fac Polytech, BP 202, Mbanza Ngungu, DEM REP CONGO
[3] Ecole Technol Super, Dept Mech Engn, Montreal, PQ H3C 1K3, Canada
[4] Univ President Joseph Kasa Vubu, Fac Polytech, BP 314, Boma, DEM REP CONGO
基金
加拿大自然科学与工程研究理事会;
关键词
cogeneration plant; exit gases from cement kilns; waste heat recovery; kalina cycles; heat transfer; electrical power; ORGANIC RANKINE-CYCLE; KALINA CYCLE; MULTIOBJECTIVE OPTIMIZATION; EXERGY ANALYSES; POWER-PLANT; RECOVERY; ENERGY; CONVERSION;
D O I
10.3390/en16052460
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The dwindling and scarcity of fossil energy sources is the basis of the energy transition, where renewable resources are increasingly valued. The purpose of the cogeneration system studied in this article is to recover the residual heat from the gases coming out of the chimneys of the cement kilns, to produce at the same time the electricity and the heat required for offices and residential houses of cement workers. Cement kilns are reputed to be energy-intensive, generating excessive heat losses. These heat losses are found mainly in the conduction-convective and radiative modes, representing about 26% of the overall heat input to the system. Nevertheless, the gases at the chimney outlet can still have temperatures between 250 and 350 degrees C, which presents a non-negligible potential for a cogeneration system. This study compares the thermal performance of different cogeneration plant configurations (KCA, KCB, and KCC systems) using the Kalina cycle to determine the best one. Several assumptions were made to reduce the complexity of the model. MATLAB and Excel software were used to solve the system of equations. After extensive analysis of the results, the KCA system showed the best performance, compared to the KCB and KCC systems, with a thermal efficiency of 22.15%, an exergy efficiency of 45.12%, and a net electrical capacity of 2565.03 kWe. Model sensitivity to concentration, temperature, and pressure variations also gave the KCA system the best-performing system. Evaluation of the excess heat flux removed from the process yields values of 7368.20 kW, 7421.86 kW, and 8094.15 kW for the KCA, KCB, and KCC systems. The results of this article serve as a decision support tool for installing the cogeneration system via the Kalina cycle in cement installations.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Thermoeconomic analysis of a novel cogeneration system for cascade recovery of waste heat from exhaust flue gases
    Fu, Ben-Ran
    Hsieh, Jui-Ching
    Cheng, Shao-Min
    Royandi, Muhamad Aditya
    [J]. APPLIED THERMAL ENGINEERING, 2024, 247
  • [2] Cogeneration from waste gases emanating from kilns in sponge iron plants: Operation and problems
    Agarwal, VP
    Sood, KC
    [J]. COGENERATION: POLICIES, POTENTIAL, AND TECHNOLOGIES, 1997, : 186 - 192
  • [3] Thermal performance of a diffusion absorption refrigeration system driven by waste heat from diesel engine exhaust gases
    Aly, Wael I. A.
    Abdo, Mohammed
    Bedair, Gamal
    Hassaneen, A. E.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 114 : 621 - 630
  • [4] Thermodynamic and economic analyses of a hybrid waste-driven CHP-ORC plant with exhaust heat recovery
    Arabkoohsar, A.
    Nami, H.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2019, 187 : 512 - 522
  • [5] Utilisation of waste heat from exhaust gases of drying process
    Arsenyeva, Olga P.
    Cucek, Lidija
    Tovazhnyanskyy, Leonid L.
    Kapustenko, Petro O.
    Savchenko, Yana A.
    Kusakov, Sergey K.
    Matsegora, Oleksandr I.
    [J]. FRONTIERS OF CHEMICAL SCIENCE AND ENGINEERING, 2016, 10 (01) : 131 - 138
  • [6] Utilisation of waste heat from exhaust gases of drying process
    Olga PArsenyeva
    Lidija uek
    Leonid LTovazhnyanskyy
    Petro OKapustenko
    Yana ASavchenko
    Sergey KKusakov
    Oleksandr IMatsegora
    [J]. Frontiers of Chemical Science and Engineering., 2016, 10 (01) - 138
  • [7] Utilisation of waste heat from exhaust gases of drying process
    Olga P. Arsenyeva
    Lidija Čuček
    Leonid L. Tovazhnyanskyy
    Petro O. Kapustenko
    Yana A. Savchenko
    Sergey K. Kusakov
    Oleksandr I. Matsegora
    [J]. Frontiers of Chemical Science and Engineering, 2016, 10 : 131 - 138
  • [8] Cogeneration based on energy recovery from exhaust gases
    Fernandez-Fernandez, Manuel
    Renedo-Estebanez, Carlos
    Ortiz-Fernandez, Alfredo
    Perez-Remesal, Severiano
    Fernandez-Diego, Inmaculada
    Manana-Canteli, Mario
    [J]. DYNA, 2011, 86 (01): : 105 - 117
  • [9] DISPOSAL OF WASTE DUST FROM CEMENT KILNS
    DAVIS, TA
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1975, 11 (06) : 669 - 673
  • [10] Thermal efficiency and drying Behaviour of Yam slices in a dryer driven by the waste heat of exhaust gases
    Ononogbo, C.
    Nwakuba, N. R.
    Nwaji, G. N.
    Nwufo, O. C.
    Nwosu, E. C.
    Okoronkwo, C. A.
    Igbokwe, J. O.
    Anyanwu, E. E.
    [J]. SCIENTIFIC AFRICAN, 2022, 17