Influence of Volume of Air on the Muzzle Velocity of the Projectile

被引:2
|
作者
Kamran, K. [1 ]
Iqbal, M. A. [1 ]
机构
[1] Indian Inst Technol Roorkee, Dept Civil Engn, Roorkee 247667, India
关键词
volume of air; muzzle velocity; ogive-nosed projectile; pressure vessel; actuator; IMPACT;
D O I
10.3103/S002565442360109X
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
In the present study, the ogival-nosed hardened steel projectile having a mass of 0.4 kg, diameter of 19 mm, calibre radius head (CRH) of 3, and length of 200 mm was used to obtain their muzzle velocity with respect to their corresponding air pressure. The two pressure vessels with varying storage capacities (20 and 90 liters) connected with the same actuator (having an opening diameter of 25.4 mm) were used to describe their influence on the muzzle velocity of the projectile. Also, the two actuators with varying opening diameters (25.4 and 50.8 mm) connected with the same pressure vessel (having a storage capacity of 90 liter) were considered to describe the influence of releasing a large volume of air on the muzzle velocity of the projectile. Based on these variations, three testing configurations such as (1) the pressure vessel with a storage capacity of 20 liter connected with the actuator having an opening diameter of 25.4 mm will be described as Case 1, (2) the actuators with an opening diameter of 25.4 connected with the pressure vessel having a storage capacity of 90 liter will be described as Case 2, and (3) the actuators with an opening diameter of 50.8 connected with the pressure vessel having a storage capacity of 90 liter will be described as Case 3, were made. Based on the experimental results, the muzzle velocities of the projectile obtained for Case 3 were found to be higher than that obtained for Case 2 at pressures varying from 10 to 55 kg/cm(2). Also, the actuator having a double opening diameter (50.8 mm) was responsible for increasing the muzzle velocity of the projectile to a maximum of 58% due to releasing a larger volume of air than that for Case 2. The muzzle velocity obtained for Case 2 was equal to that obtained for Case 1 at low pressure (10 kg/cm(2)). However, the muzzle velocity obtained for Case 2 was higher than that obtained for Case 1 at pressures varying from 15 to 55 kg/cm(2) and increased to a maximum of 6%, describing the influence of using the pressure vessel having 4.5 times higher storage capacity than that used for Case 1. Hence, using the actuator with a large opening diameter was more effective for increasing the muzzle velocity of the projectile than the pressure vessel with a large storage capacity.
引用
收藏
页码:1821 / 1827
页数:7
相关论文
共 50 条
  • [1] Influence of Volume of Air on the Muzzle Velocity of the Projectile
    K. Kamran
    M. A. Iqbal
    Mechanics of Solids, 2023, 58 : 1821 - 1827
  • [2] Influence of Magnetically Confined Plasma on the Muzzle Velocity of Gun Projectile
    Wang, Yu
    Ma, Tiehua
    Pei, Dongxing
    Chen, Changxin
    Feng, Kaiqiang
    Zhang, Debiao
    Wu, Zhibo
    IEEE ACCESS, 2020, 8 : 72661 - 72670
  • [3] Study on the influence of projectile on muzzle disturbance
    Liu, Fei-fei
    Song, Yan-ming
    Yu, Hai-long
    Lin, Wen-ding
    Zhang, Jie
    Si, Zhi-hui
    Ding, Ming-kang
    Rui, Xiao-ting
    DEFENCE TECHNOLOGY, 2018, 14 (05): : 570 - 577
  • [4] Study on the influence of projectile on muzzle disturbance
    Feifei Liu
    Yanming Song
    Hailong Yu
    Wending Lin
    Jie Zhang
    Zhihui Si
    Mingkang Ding
    Xiaoting Rui
    Defence Technology, 2018, 14 (05) : 570 - 577
  • [5] Study on the influence of projectile on muzzle disturbance
    Fei-fei Liu
    Yan-ming Song
    Hai-long Yu
    Wen-ding Lin
    Jie Zhang
    Zhi-hui Si
    Ming-kang Ding
    Xiao-ting Rui
    Defence Technology, 2018, (05) : 570 - 577
  • [6] Study on Precise Measurement Method for Muzzle Velocity of Projectile
    Zhao Xia
    Hong Qing
    Liu Zhengchun
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOL. 3, 2008, : 1440 - 1444
  • [7] A new method for muzzle velocity measurement on spinning projectile
    Yu Weibo
    Zhang Lifeng
    Xuan Zhaolong
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 804 - 807
  • [8] The muzzle flow field induced by hyper-velocity projectile
    Li Z.
    Wang H.
    Chen J.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2017, 49 (10): : 53 - 59
  • [9] Study on projectile muzzle velocity measurement based on rotational speed
    Ministry of Education Key Laboratory of Instrumentation Science and Dynamic Measurement, North University of China, Taiyuan 030051, Shanxi, China
    Pei, D.-X. (peidongxing@nuc.edu.cn), 1600, China Ordnance Industry Corporation (34):
  • [10] Study on muzzle velocity precision measurement of high-peed projectile
    Ding, LB
    Zhang, H
    Zhou, XD
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 3159 - 3162