Optimized repetitive sampling X-bar control chart: performance evaluation and comparison with Shewhart control chart

被引:1
|
作者
Munoz, Jose J. [1 ]
Aslam, Muhammad [2 ]
Campuzano, Manuel J. [1 ]
机构
[1] Univ Magdalena, Fac Ingn, Santa Marta, Colombia
[2] King Abdulaziz Univ, Fac Sci, Dept Stat, Jeddah, Saudi Arabia
关键词
single plan; resampling; simulation; efficiency; sample size; DESIGN;
D O I
10.3389/fams.2023.1285023
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
When initial sample information falls short of enabling industrial engineers to confidently make decisions about lot quality assessment, repetitive sampling emerges as a solution. In this study, we present an optimized repetitive sampling control chart for X-bar values. Through meticulous analysis, we determined the optimal control chart coefficients. Additionally, we established the control chart parameters for scenarios where the sample size equals the average sample number, encompassing both in-control and out-of-control processes. To underscore the effectiveness of our proposed chart compared to the traditional Shewhart control chart, we provide comprehensive tables across various sample sizes. By meticulously examining these tables alongside the corresponding control charts, the chart's efficacy in relation to the Shewhart alternative becomes evident.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Impact of Different Repetitive Sampling Schemes on the Performance of X-bar Control Chart
    Mughal, Muhammad Anwar
    Azam, Muhammad
    Aslam, Muhammad
    [J]. PAKISTAN JOURNAL OF STATISTICS AND OPERATION RESEARCH, 2020, 16 (01) : 191 - 201
  • [2] X-bar control chart design with asymmetric control limits and triple sampling
    Oprime, Pedro Carlos
    da Costa, Naijela Janaina
    Mozambani, Carlos Ivan
    Goncalves, Celso Luiz
    [J]. INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2019, 104 (9-12): : 3313 - 3326
  • [3] X-bar control chart design with asymmetric control limits and triple sampling
    Pedro Carlos Oprime
    Naijela Janaina da Costa
    Carlos Ivan Mozambani
    Celso Luiz Gonçalves
    [J]. The International Journal of Advanced Manufacturing Technology, 2019, 104 : 3313 - 3326
  • [4] Design of X-bar control chart based on Inverse Rayleigh Distribution under repetitive group sampling
    Shafqat, Ambreen
    Huang, Zhensheng
    Aslam, Muhammad
    [J]. AIN SHAMS ENGINEERING JOURNAL, 2021, 12 (01) : 943 - 953
  • [5] A fuzzy system for VSI X-bar control chart
    Department of Industrial Engineering and Management, National Yunlin University of Science and Technology, Taiwan
    [J]. WCSE - Int. Workshop Comput. Sci. Eng., (427-429):
  • [6] Max chart: Combining X-bar chart and S chart
    Chen, GM
    Cheng, SW
    [J]. STATISTICA SINICA, 1998, 8 (01) : 263 - 271
  • [7] Two alternatives to the Shewhart (X)over-bar control chart
    Klein, M
    [J]. JOURNAL OF QUALITY TECHNOLOGY, 2000, 32 (04) : 427 - 431
  • [8] Evaluating the performance of variable scheme X-bar control chart: a Taguchi loss approach
    Amiri, Farzad
    Noghondarian, Kazem
    Safaei, Abdul Sattar
    [J]. INTERNATIONAL JOURNAL OF PRODUCTION RESEARCH, 2014, 52 (18) : 5385 - 5395
  • [9] The Improved Quality-oriented X-bar and R Control Chart
    Zhang Yu
    Yang Musheng
    [J]. RECENT ADVANCE IN STATISTICS APPLICATION AND RELATED AREAS, PTS 1 AND 2, 2008, : 173 - 176
  • [10] A New Control Scheme Always Better Than X-Bar Chart
    Lee, Sang-Ho
    Jun, Chi-Hyuck
    [J]. COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2010, 39 (19) : 3492 - 3503