CAD-CAM and analog occlusal splints comparison based on the amount of occlusal adjustments. 3D analysis of the volumetric changes: A pilot study

被引:1
|
作者
Blasi, Alvaro [1 ,2 ]
Henarejos-Domingo, Victor [1 ]
Palacios-Banuelos, Ricardo [1 ,4 ]
Vidal-Ponsoda, Carla [1 ]
Aparicio, Conrado [3 ]
Roig, Miguel [1 ,3 ]
机构
[1] Univ Int Catalunya, Fac Dent, Dept Restorat Dent, Barcelona, Spain
[2] Georgia Augusta Univ, Dept Restorat Sci, Dent Coll, Augusta, Georgia
[3] Univ Int Catalunya, Fac Dent, Barcelona, Spain
[4] Univ Int Catalunya, Fac Dent, Dept Restorat Dent, Hosp Univ Gen Catalunya, Josep Trueta St, s-n, Barcelona 08195, Spain
关键词
analog; digital; milled; occlusal device; occlusion; precision; TEMPOROMANDIBULAR DISORDERS; CONVENTIONAL IMPRESSION; ACCURACY; BRUXISM; PRECISION; TIME;
D O I
10.1111/jerd.13080
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo evaluate the volumetric changes on occlusal surface of computer-aided design and computer-aided manufacturing (CAD-CAM) occlusal devices fabricated following a fully digital workflow after occlusal adjustment, compared to those fabricated with an analog workflow. Materials and MethodsEight participants were included in this clinical pilot study, receiving two different occlusal devices fabricated with two different workflows, fully analog and fully digital. Every occlusal device was scanned before and after the occlusal adjustments to compare the volumetric changes using a reverse engineering software program. Moreover, three independent evaluators assessed a semi-quantitative and qualitative comparison using visual analog scale and dichotomous evaluation. The Shapiro-Wilk test was performed to validate normal distribution assumption, and a dependent t-Student test for paired variables was used to determine statistically significant differences (p-value < 0.05). ResultsThe root mean square value was extracted from the 3-Dimensional (3D) analysis of the occlusal devices. The average values of the root mean square were higher for the analogic technique (0.23 & PLUSMN; 0.10 mm) than the digital technique (0.14 & PLUSMN; 0.07 mm) but the differences were not statistically significant (paired t-Student test; p = 0.106) between the two fabrication techniques. The semiquantitative visual analog scale values between the impression for the digital (5.08 & PLUSMN; 2.4 cm) and analog (3.80 & PLUSMN; 3.3 cm) technique were significant (p < 0.001), and statistically significant differences values were assessed for evaluator 3 compared to the other evaluators (p < 0.05). However, the three evaluators agreed on the qualitative dichotomous evaluation in 62% of the cases, and at least two evaluators agreed in 100% of the evaluations. ConclusionsOcclusal devices fabricated following a fully digital workflow resulted in fewer occlusal adjustments, as they could be a valid alternative to those fabricated following an analog workflow. Clinical SignificanceFabricated occlusal devices following a fully digital workflow could have some advantages over analog workflow such reduce occlusal adjustments at delivery appointment, which can result in reduced chair time and therefore increased comfort for the patient and clinician.
引用
收藏
页码:1271 / 1278
页数:8
相关论文
共 5 条
  • [1] Comparative Analysis between Conventional Acrylic, CAD/CAM Milled, and 3D CAD/CAM Printed Occlusal Splints
    Abad-Coronel, Cristian
    Ruano Espinosa, Carolina
    Ordonez Palacios, Sofia
    Paltan, Cesar A.
    Fajardo, Jorge I.
    MATERIALS, 2023, 16 (18)
  • [2] Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns-cast-free vs 3D printed cast-based
    Graf, Tobias
    Gueth, Jan-Frederik
    Diegritz, Christian
    Liebermann, Anja
    Schweiger, Josef
    Schubert, Oliver
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (06): : 351 - 360
  • [3] Comparison of Dimensional Changes Between CAD-CAM Milled Complete Denture Bases and 3D Printed Complete Denture Bases: An In Vitro Study
    Helal, Mohamed Ahmed
    Abdelrahim, Ramy Abdallah
    Zeidan, Ahmed Abd El-latif
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 : 11 - 19
  • [4] Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: An in vitro study
    Herschdorfer, Laura
    Negreiros, William Matthew
    Gallucci, German O.
    Hamilton, Adam
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (06): : 905 - 910
  • [5] Influence of 3D analysis software on measured deviations of CAD-CAM resin crowns from virtual design file: An in-vitro study
    Yilmaz, Burak
    Marques, Vinicius Rizzo
    Donmez, Mustafa Borga
    Rodriguez Cuellar, Alfonso
    Lu, Wei-En
    Abou-Ayash, Samir
    Cakmak, Gulce
    JOURNAL OF DENTISTRY, 2022, 118