Effect of the volume of resected discoid lateral meniscus on the contact stress of the tibiofemoral joint: A finite element analysis

被引:5
|
作者
Yokoe, Takuji [1 ]
Ouchi, Koki [1 ]
Matsumoto, Taisei [1 ]
Tajima, Takuya [1 ]
Chosa, Etsuo [1 ]
机构
[1] Univ Miyazaki, Fac Med, Dept Med Sensory & Motor Organs, Div Orthopaed Surg, Miyazaki 8891692, Japan
来源
KNEE | 2023年 / 42卷
关键词
Discoid meniscus; Meniscectomy; Contact stress; Tibiofemoral joint; Finite element analysis; TIBIAL ARTICULAR-CARTILAGE; OSTEOCHONDRITIS-DISSECANS; FEMORAL CONDYLE; ARTHROSCOPIC TREATMENT; PARTIAL MENISCECTOMY; CHILDREN;
D O I
10.1016/j.knee.2023.02.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Partial meniscectomy is commonly performed for symptomatic patients with discoid lateral meniscus (DLM) if conservative treatment fails. However, the development of knee osteoarthritis and osteochondral lesion are detrimental postoperative complica-tions. This study aimed to evaluate the effect of the volume of resected DLM on the contact stress of the tibiofemoral joint using a finite element analysis.Methods: Subject-specific finite-element models of the knee joint of a patient with DLM were developed from computed tomographic and magnetic resonance images. To evaluate the effect of partial meniscectomy on the contact stress in the lateral tibiofemoral joint, six knee models were created in the study (the native DLM, and five partially meniscectomized DLMs (according to the preserved width of the meniscus: 12 mm, 10 mm, 8 mm, 6 mm, and 4 mm)).Results: As the volume of resected DLM increased, higher contact stress was applied to the lateral tibiofemoral joint. Greater contact stress was applied to the preserved lateral menis-cus than to the native DLM.Conclusions: From a biomechanical viewpoint, the native DLM was the most protective against lateral tibiofemoral contact stress in comparison to partially meniscectomized DLMs.(c) 2023 Elsevier B.V. All rights reserved.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [1] Effect of residual volume after surgery of the discoid lateral meniscus on tibiofemoral joint biomechanics: a finite element analysis
    Xin Shen
    Meifeng Lu
    Muzi Liu
    Ronghui Xie
    Shiguo Gong
    Chunjing Yang
    Guicai Sun
    Journal of Orthopaedic Surgery and Research, 19
  • [2] Effect of residual volume after surgery of the discoid lateral meniscus on tibiofemoral joint biomechanics: a finite element analysis
    Shen, Xin
    Lu, Meifeng
    Liu, Muzi
    Xie, Ronghui
    Gong, Shiguo
    Yang, Chunjing
    Sun, Guicai
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [3] The Effect of Lower Limb Alignment on Tibiofemoral Joint Contact Biomechanics after Medial Meniscus Posterior Root Repair: A Finite-Element Analysis
    Berk, Alexander N.
    Cregar, William M.
    Wang, Shangcheng
    Habet, Nahir A.
    Ifarraguerri, Anna Maria
    Trofa, David P.
    Piasecki, Dana P.
    Fleischli, James E.
    Saltzman, Bryan M.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2024, 32 (11) : e558 - e567
  • [4] Finite element study of a partial meniscectomy of a complete discoid lateral meniscus in adults
    Liu, Wenlong
    Sun, Xiaoxin
    Liu, Wenjing
    Liu, Hao
    Zhai, Haoyuan
    Zhang, Dingding
    Tian, Faming
    MEDICAL ENGINEERING & PHYSICS, 2022, 107
  • [5] Finite element analysis of a healthy knee joint at deep squatting for the study of tibiofemoral and patellofemoral contact
    Kothurkar, Rohan
    Lekurwale, Ramesh
    Gad, Mayuri
    Rathod, Chasanal M.
    JOURNAL OF ORTHOPAEDICS, 2023, 40 : 7 - 16
  • [6] The effect of complete radial lateral meniscus posterior root tear on the knee contact mechanics: a finite element analysis
    Bao, H. R. C.
    Zhu, D.
    Gong, H.
    Gu, G. S.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (02) : 256 - 263
  • [7] Effect of surface matching mismatch of focal knee articular prosthetic on tibiofemoral contact stress using finite element analysis
    Lee, J. A.
    Koh, Y-G.
    Kim, P. S.
    Park, J-H.
    Kang, K-T.
    BONE & JOINT RESEARCH, 2023, 12 (08): : 497 - 503
  • [8] A finite element 3D model of in vivo human knee joint based on MRI for the tibiofemoral joint contact analysis
    Hao, Zhixiu
    Jim, Dewen
    Zhang, Yu
    Zhang, Jichuan
    DIGITAL HUMAN MODELING, 2007, 4561 : 616 - 622
  • [9] Finite element contact analysis of the hip joint
    Bachtar, Fuziansyah
    Chen, Xian
    Hisada, Toshiaki
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (08) : 643 - 651
  • [10] Finite element contact analysis of the hip joint
    Fuziansyah Bachtar
    Xian Chen
    Toshiaki Hisada