Mechanisms of performance degradation in a double-suction centrifugal pump under inflow distortions

被引:1
|
作者
Wang, Wei [1 ,2 ]
Liu, Boxing [1 ]
Lu, Jinling [1 ,2 ]
Feng, Jianjun [1 ,2 ]
Zhang, Lefu [1 ,2 ]
Luo, Xingqi [1 ,2 ]
机构
[1] Xian Univ Technol, Fac Water Resources & Hydroelect Engn, Xian 710048, Shaanxi, Peoples R China
[2] Xian Univ Technol, State Key Lab Ecohydraul Northwest Arid Reg, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
Double-suction pump; bent inlet pipe; inflow distortion; pressure fluctuation; low-frequency disturbance; UNSTEADY PRESSURE PULSATION; REACTOR COOLANT PUMPS; ANALYTICAL PREDICTION; FLOW; VIBRATION; 2D;
D O I
10.1177/09544089221104776
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Inlet pipes of the centrifugal pump are generally bent to fit in the limited installation space, which can cause inflow distortions for two sides of the double-suction impeller. This study aimed to understand the effect of primary geometric parameters of inlet pipes, including corner angle, straight pipe length downstream of elbow, and turning radius, on pump performance and pressure fluctuations. The pump head, efficiency, and pressure fluctuations were measured for six kinds of inlet pipes in the experiment. Unsteady numerical simulations were performed to understand the flow mechanisms. Results indicate that the bending of inlet pipes is a significant reason for the loss of pump head and efficiency. The penalty on pump performance is augmented by the increase in corner angle, decrease in turning radius, and installation of a short straight pipe downstream of the elbow. Pump efficiency could be maximally reduced by 6.58% with a large corner angle and a small turning radius. The bending of inlet pipes induces pressure imbalance for the two sides of the impeller and increases low-frequency disturbance in the suction chamber, which are responsible for the performance loss. Numerical results reveal that the low-frequency disturbance is caused by the vortex formed in the suction chamber, and the accompanying secondary vortex aggravates the pressure fluctuation synchronously. Parametric studies conclude that the corner angle should be minimized to reduce the penalty on pump performance and pressure fluctuations, and a long straight pipe downstream of the elbow can be installed to decrease vibration for the pump with bent inlet pipes.
引用
收藏
页码:680 / 689
页数:10
相关论文
共 50 条
  • [1] COMPARATIVE STUDY ON HYDRAULIC PERFORMANCE OF SINGLE-SUCTION CENTRIFUGAL PUMP AND DOUBLE-SUCTION CENTRIFUGAL PUMP
    Wang, Chaoyue
    Wang, Fujun
    Zou, Zhichao
    [J]. PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2017, VOL 1A, 2017,
  • [2] The influence of ring clearance on the performance of a double-suction centrifugal pump
    Lei, Lei
    Wang, Tao
    Qiu, Bo
    Yu, He
    Liu, Yunqi
    Dong, Yuancheng
    [J]. PHYSICS OF FLUIDS, 2024, 36 (02)
  • [3] Numerical Simulation of Centrifugal Pump with Double-Suction Impeller
    An, Young-Joon
    Shin, Byeong Rog
    [J]. 10TH ASIAN INTERNATIONAL CONFERENCE ON FLUID MACHINERY, 2010, 1225 : 456 - 464
  • [4] Effects of concentration and size of silt particles on the performance of a double-suction centrifugal pump
    Wang, Zhiyuan
    Qian, Zhongdong
    [J]. ENERGY, 2017, 123 (123) : 36 - 46
  • [5] Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump
    Qianqian Li
    Shiyang Li
    Peng Wu
    Bin Huang
    Dazhuan Wu
    [J]. Chinese Journal of Mechanical Engineering, 2021, 34 (01) : 192 - 209
  • [6] Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump
    Qianqian Li
    Shiyang Li
    Peng Wu
    Bin Huang
    Dazhuan Wu
    [J]. Chinese Journal of Mechanical Engineering, 2021, 34
  • [7] Optimization of a single-stage double-suction centrifugal pump
    Skerlavaj, Aljaz
    Morgut, Mitja
    Jost, Dragica
    Nobile, Enrico
    [J]. 34TH UIT HEAT TRANSFER CONFERENCE 2016, 2017, 796
  • [8] Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump
    Li, Qianqian
    Li, Shiyang
    Wu, Peng
    Huang, Bin
    Wu, Dazhuan
    [J]. CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2021, 34 (01)
  • [9] Flow characteristics in a V-shaped region of a suction performance curve in a double-suction centrifugal pump
    Kang, Donghyuk
    Yamazaki, Satoshi
    Kagawa, Shusaku
    An, Byungjin
    Nohmi, Motohiko
    Yokota, Kazuhiko
    [J]. International Journal of Fluid Machinery and Systems, 2019, 12 (01) : 89 - 98
  • [10] Numerical investigation of sediment erosion to the impeller in a double-suction centrifugal pump
    Yang, C. X.
    Dong, F. D.
    Cheng, X. R.
    [J]. 6TH INTERNATIONAL CONFERENCE ON PUMPS AND FANS WITH COMPRESSORS AND WIND TURBINES (ICPF2013), 2013, 52