Characterization of the Molecular Weight of Hyaluronan in Eye Products Using a Novel Method of Size Exclusion High-Pressure Liquid Chromatography

被引:7
|
作者
Nguyen, Lawrence [1 ]
Lin, Xiao [1 ]
Verma, Sudhir [1 ,2 ]
Puri, Sudan [1 ]
Hascall, Vincent [3 ]
Gesteira, Tarsis Ferreira [1 ]
Coulson-Thomas, Vivien J. [1 ,4 ]
机构
[1] Univ Houston, Coll Optometry, Houston, TX USA
[2] Univ Delhi, Deen Dayal Upadhyaya Coll, Dept Zool, Delhi, India
[3] Cleveland Clin, Cleveland Hts, OH USA
[4] Univ Houston, Coll Optometry, 4401 Martin Luther King Blvd,HB1 TOSI 246, Houston, TX 77204 USA
来源
关键词
glycosaminoglycans; hyaluronan; cornea; tear film; dry eye disease; over the counter eye drops; DRY EYE; SODIUM HYALURONATE; CONTACT-LENSES; STREPTOCOCCUS-ZOOEPIDEMICUS; MASS DETERMINATION; ANTERIOR SEGMENT; ARTIFICIAL TEARS; ROOSTER COMB; ACID; CELLS;
D O I
10.1167/tvst.12.4.13
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Hyaluronan (HA) exists in two forms, high molecular weight HA (HMWHA) and low molecular weight HA (LMWHA), which have distinct physiological functions. Therefore it is imperative to know the form of HA within pharmaceutical products, including eye products. This study developed an accurate, sensitive, and quantitative method to characterize the form of HA in eye products. Thereafter, the effects of the HA-containing eye products on corneal wound healing were investigated.Methods: The MW distributions and concentrations of HA in over the counter eye products were determined by size exclusion chromatography (SEC) high-pressure liquid chromatography (HPLC). The effects of the eye products containing HA on corneal wound healing were characterized both in vitro and in vivo using the scratch assay and the debridement wound model, respectively.Results: The concentrations and MWs of HA were successfully determined within a range of 0.014 to 0.25 mg/mL using SEC HPLC. The concentrations of HA in the ophthalmic products varied from 0.14 to 4.0 mg/mL and the MWs varied from & SIM;100 kDa to >2500 kDa. All but one HA-containing eye product had an inhibitory effect on corneal wound healing, whereas pure HA promoted corneal wound healing.Conclusions: A novel SEC-HPLC method was developed for quantifying and characterizing the MW of HA in eye products. Although HA promoted corneal wound healing, HA-containing eye products inhibited corneal wound healing, likely caused by preservatives. Translational Relevance: SEC-HPLC could be implemented as a routine method for determining the form of HA in commercially available ophthalmic products.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Characterization of the molecular weight of hyaluronan in eye products using a novel method of size exclusion high-pressure liquid chromatography
    Verma, Sudhir
    Nguyen, Lawrence
    Lin, Xiao
    Puri, Sudan
    Hascall, Vincent
    Ferreira, Tarsis
    Coulson-Thomas, Vivien
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [2] Effect of detector wavelength on the determination of the molecular weight of humic substances by high-pressure size exclusion chromatography
    O'Loughlin, E
    Chin, YP
    WATER RESEARCH, 2001, 35 (01) : 333 - 338
  • [3] ANALYSIS OF OLIGOMERIC FERMENTATION SUBSTRATES AND PRODUCTS BY HIGH-PRESSURE SIZE EXCLUSION CHROMATOGRAPHY
    OH, K
    JANSSENS, J
    GROHMANN, K
    HIMMEL, ME
    BIOTECHNOLOGY LETTERS, 1982, 4 (07) : 405 - 410
  • [5] Determination of the Molecular Weight of Low-Molecular-Weight Heparins by Using High-Pressure Size Exclusion Chromatography on Line with a Triple Detector Array and Conventional Methods
    Bisio, Antonella
    Mantegazza, Alessandra
    Vecchietti, Davide
    Bensi, Donata
    Coppa, Alessia
    Torri, Giangiacomo
    Bertini, Sabrina
    MOLECULES, 2015, 20 (03) : 5085 - 5098
  • [6] SIZE-EXCLUSION CHARACTERIZATION OF PAPER COATING STARCHES USING A HIGH-PRESSURE LIQUID CHROMATOGRAPH
    PAPANTONAKIS, M
    TAPPI, 1980, 63 (05): : 65 - 69
  • [7] THE DETERMINATION OF HYALURONAN MOLECULAR-WEIGHT DISTRIBUTION BY MEANS OF HIGH-PERFORMANCE SIZE EXCLUSION CHROMATOGRAPHY
    ORVISKY, E
    SOLTES, L
    CHABRECEK, P
    NOVAK, I
    KERY, V
    STANCIKOVA, M
    VINS, I
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (18): : 3203 - 3218
  • [8] EFFECT OF DETECTOR WAVELENGTH ON THE DETERMINATION OF THE MOLECULAR-WEIGHT OF HUMIC SUBSTANCES BY HIGH-PRESSURE SIZE-EXCLUSION CHROMATOGRAPHY
    OLOUGHLIN, EJ
    CHIN, YP
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 199 - ENVR
  • [9] HIGH-PRESSURE SIZE-EXCLUSION CHROMATOGRAPHY OF ANTICOAGULANT MATERIALS
    MULLER, D
    NDOUMENZE, M
    JOZEFONVICZ, J
    JOURNAL OF CHROMATOGRAPHY, 1984, 297 (AUG): : 351 - 358
  • [10] Revisiting molecular weight and polydispersity measurements by high-pressure size exclusion chromatography: Accounting for changes in analytical standards and isolation techniques
    McAdams, Brandon
    Aiken, George
    Arnold, William
    Chin, Yu-Ping
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252