Minimum anesthetic concentration of isoflurane and sevoflurane and cardiorespiratory effects of varying inspired oxygen fractions in Magellanic penguins (Spheniscus magellanicus)

被引:0
|
作者
da Silva, Andre Nicolai Elias [1 ]
Dutra, Gustavo Henrique Pereira [1 ,2 ]
Justo, Andre Augusto [1 ]
de Araujo, Giuliano Souza Mendonca [1 ]
Bressan, Thais Feres [1 ]
Carregaro, Adriano Bonfim [1 ]
机构
[1] Univ Sao Paulo, Sch Anim Sci & Food Engn, Dept Vet Med, Ave Duque de Caxias Norte 225, BR-13635900 Pirassununga, SP, Brazil
[2] Santos Aquarium, Vet Unit Santos Aquarium, BR-11030600 Santos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Acid-base profile; Anesthesia; Birds; Inhalation anesthesia; Oxygen supplementation; CARDIOVASCULAR DOSE-RESPONSE; ALVEOLAR CONCENTRATION; BUTORPHANOL; CHICKENS; RESPIRATION; REDUCTION; INDUCTION; MORTALITY; PATTERNS; HEART;
D O I
10.1007/s11259-024-10336-w
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The aim of this study was to determine the minimum anesthetic concentration of isoflurane (MAC(ISO)) and sevoflurane (MAC(SEVO)) and evaluate the cardiorespiratory changes induced by varying fractions of inspired oxygen (FiO(2)) in Magellanic penguins (Spheniscus magellanicus). Twenty adult penguins (3.53 +/- 0.44 kg) of undetermined sex were used. Both MAC(ISO) (n = 9) and MAC(SEVO) (n = 13) were established using an up-and-down design. Next, twelve mechanically ventilated penguins were maintained at 1 MAC(ISO) or 1 MAC(SEVO) (n = 6 per group) with the FiO(2) initially set at 1.0. Three FiO(2) values (0.6, 0.4 and 0.2) were then held constant during anesthesia for 20 minutes each. Arterial blood samples were collected for gas analysis after the 20-minute period for each FiO(2). Mean +/- SD MAC(ISO) was 1.93 +/- 0.10% and MAC(SEVO) was 3.53 +/- 0.13%. Other than heart rate at 0.6 FiO(2) (86 +/- 11 beats/minute in MAC(ISO) and 132 +/- 37 beats/minute in MAC(SEVO); p = 0.041), no significant cardiorespiratory differences were detected between groups. In both groups, decreasing the FiO(2) produced increased pH values and reduced partial pressures of carbon dioxide and bicarbonate. Partial pressures of oxygen (PaO2) gradually lowered from 1.0 FiO(2) through 0.2 FiO(2), though hypoxemia (PaO2 < 80 mmHg) occurred only with the latter FiO(2). The MAC(ISO) and the MAC(SEVO) for the Magellanic penguin fell within the upper range of reported avian MAC estimates. To prevent hypoxemia in healthy, mechanically ventilated, either isoflurane- or sevoflurane-anesthetized Magellanic penguins, a minimum FiO(2) of 0.4 should be used.
引用
收藏
页码:1621 / 1630
页数:10
相关论文
共 2 条
  • [1] Effects of inspired oxygen fractions in rabbits anesthetized with isoflurane or sevoflurane, maintained on spontaneous ventilation
    Horr, M.
    Nunes, N.
    Biteli, E. G. F.
    Lopes, P. C. F.
    Gering, A. P.
    Moro, J., V
    Rocha, F. D. L.
    [J]. ARQUIVO BRASILEIRO DE MEDICINA VETERINARIA E ZOOTECNIA, 2019, 71 (03) : 944 - 952
  • [2] Anesthesia with Isoflurane and Sevoflurane in the Crested Serpent Eagle (Spilornis cheela hoya): Minimum Anesthetic Concentration, Physiological Effects, Hematocrit, Plasma Chemistry and Behavioral Effects
    Chan, Fang-Tse
    Chang, Geng-Ruei
    Wang, Hsien-Chi
    Hsu, Tien-Huan
    [J]. JOURNAL OF VETERINARY MEDICAL SCIENCE, 2013, 75 (12): : 1591 - 1600