Triangular microwell for single cell trapping and short-term culturing: Cellular study and analysis of Leukemia cell line

被引:0
|
作者
Bhanpattanakul, Sudchaya [1 ,2 ]
Wongpakham, Tepparit
Theewasutrakul, Patrakrit [1 ]
Ketpun, Dettachai [6 ]
Srituravanich, Werayut
Sripumkhai, Witsaroot [7 ]
Pattamang, Pattaraluck [7 ]
Chanasakulniyom, Mayuree [8 ]
Piyaviriyakul, Prapruddee [1 ,3 ]
Jeamsaksiri, Wutthinun
Sailasuta, Achariya [1 ,2 ]
Tharasanit, Theerawat [4 ]
Pimpin, Alongkorn [5 ]
Kaewamatawong, Theerayuth [1 ,2 ]
机构
[1] Chulalongkorn Univ, Fac Vet Sci, Ctr Excellence Compan Anim Canc CE CAC, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Vet Sci, Dept Pathol, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Vet Sci, Dept Physiol, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Fac Vet Sci, Dept Obstet Gynaecol & Reprod, Bangkok 10330, Thailand
[5] Chulalongkorn Univ, Fac Engn, Dept Mech Engn, Micro Nano Electromech Integrated Device Res Unit, Bangkok 10330, Thailand
[6] Walailak Univ, Akkhraratchakumari Vet Coll, Fac Vet Pathol, Nakhon Si Thammarat 80161, Thailand
[7] Thai Microelect Ctr TMEC, Chachoengsao 24000, Thailand
[8] Mahidol Univ, Fac Med Technol, Bangkok 10700, Thailand
来源
SCIENCEASIA | 2023年 / 49卷 / 04期
关键词
cell culture; cell viability; microfluidic device; polydimethylsiloxane; single cell trapping; MICROFLUIDICS; TECHNOLOGIES;
D O I
10.2306/scienceasia1513-1874.2023.057
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Microfluidic system is a single cell analysis (SCA) platform which is useful for cellular biological study. However, the system still needs further development and improvement for a complete high-throughput single cell analysis. The purpose of this study was to design and develop a microfluidic device for trapping and culturing single cells of human leukemia cell line. Trapping achievement and short-term culture capability were also evaluated. Polydimethylsiloxane (PDMS) microfluidic device consisted of two layers, one of which was a main channel with a dimension of 5 mm wide, 15 mm long, 70 & mu;m high; and an array of 40 & mu;m equilateral triangular microwells with 30 & mu;m deep arranged in downward oblique direction. Trapping efficacy results were about 70.8% for single cells. The effects of different cell densities on cell trapping rates showed that the increment of cell density reduced the single cell trapping capability, and the trapping method was not harmful to the cells. Potential short-term culture of single cell trapping examined by Trypan blue dye assay and Calcein AM/EthD-1 fluorescent staining revealed 80% and 75% of cellular viability after 24 and 48 h of incubation, respectively. In summary, our developed PDMS microfluidic device succeeded in single cell trapping pattern and short-term culturing of leukemia cell line single cells.
引用
收藏
页码:588 / 594
页数:9
相关论文
共 50 条
  • [1] Development of A Triangular Microwell for Single Cell Trapping - Computational Study
    Tongmanee, Tewan
    Pimpin, Alongkorn
    Srituravanich, Werayut
    Ketpun, Dettachai
    Sailasuta, Achariya
    Jeamsaksiri, Wutthinan
    Sripumkhai, Witsaroot
    Piyaviriyakul, Prapruddee
    [J]. 2015 8TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2015,
  • [2] Single cell trapping and DNA damage analysis using microwell arrays
    Wood, David K.
    Weingeist, David M.
    Bhatia, Sangeeta N.
    Engelward, Bevin P.
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2010, 107 (22) : 10008 - 10013
  • [3] Trapping cells on a stretchable microwell array for single-cell analysis
    Yuli Wang
    Pavak Shah
    Colleen Phillips
    Christopher E. Sims
    Nancy L. Allbritton
    [J]. Analytical and Bioanalytical Chemistry, 2012, 402 : 1065 - 1072
  • [4] Trapping cells on a stretchable microwell array for single-cell analysis
    Wang, Yuli
    Shah, Pavak
    Phillips, Colleen
    Sims, Christopher E.
    Allbritton, Nancy L.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (03) : 1065 - 1072
  • [5] Electroactive Microwell Arrays for Highly Efficient Single-Cell Trapping and Analysis
    Kim, Soo Hyeon
    Yamamoto, Takatoki
    Fourmy, Dominique
    Fujii, Teruo
    [J]. SMALL, 2011, 7 (22) : 3239 - 3247
  • [6] Erratum to: Trapping cells on a stretchable microwell array for single-cell analysis
    Yuli Wang
    Pavak Shah
    Colleen Phillips
    Christopher E. Sims
    Nancy L. Allbritton
    [J]. Analytical and Bioanalytical Chemistry, 2012, 404 : 2519 - 2519
  • [7] In-house polydimethylsiloxane microfluidic device on single cell trapping and culturing of Leukemia cell line: comparison between conventional and conventional with centrifugal methods
    Pimpin, Alongkorn
    Bhanpattanakul, Sudchaya
    Wongpakham, Tepparit
    Tawatcharaporn, Chomkwan
    Siha-umphai, Thanawit
    Sinsiriphan, Mookdapa
    Chalermchuang, Atikan
    Tongmanee, Tewan
    Thanomsridetchai, Attawut
    Suwannaphan, Thammawit
    Sripumkhaie, Witsaroot
    Pattamang, Pattaraluck
    Chanasakulniyom, Mayuree
    Piyaviriyakul, Praprudee
    Jeamsaksiri, Wutthinun
    Sailasuta, Achariya
    Tharasanit, Theerawat
    Kaewamatawong, Theerayuth
    [J]. THAI JOURNAL OF VETERINARY MEDICINE, 2023, 53 (02): : 237 - 245
  • [8] Letter to the Editor regarding "Trapping cells on a stretchable microwell array for single-cell analysis"
    Deutsch, Mordechai
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (20) : 6605 - 6605
  • [9] Letter to the Editor regarding “Trapping cells on a stretchable microwell array for single-cell analysis”
    Mordechai Deutsch
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 6605 - 6605
  • [10] Single cell analysis of short-term dry eye induced changes in cornea immune cell populations
    Alam, Jehan
    Yaman, Ebru
    Silva, Gerda Cristal Villalba
    Chen, Rui
    de Paiva, Cinita S.
    Stepp, Mary Ann
    Pflugfelder, Stephen C.
    [J]. FRONTIERS IN MEDICINE, 2024, 11