Estimation of Heart Rate and Heart Rate Variability with Real-Time Images Based on Independent Component Analysis and Particle Swarm Optimization

被引:1
|
作者
Su, Te-Jen [1 ,2 ]
Hung, Ya-Chung [1 ]
Pan, Tzung-Shiarn [1 ]
Lin, Wei-Hong [1 ]
Wang, Shih-Ming [3 ]
Lee, Yu-Cheng [1 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Dept Elect Engn, Kaohsiung 80782, Taiwan
[2] Natl Kaohsiung Univ Sci & Technol, Dept Comp & Commun Engn, Kaohsiung 80782, Taiwan
[3] Cheng Shiu Univ, Dept Comp Sci & Informat Engn, Kaohsiung 833, Taiwan
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 13期
关键词
independent component analysis; heart rate variability; heart rate; particle swarm optimization algorithm; ASSOCIATION;
D O I
10.3390/app13137605
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
With the rapid development of science and technology, the living habits of people have also changed from those in the past; the diet, living environment, various life pressures, etc., all overwhelm the body and mind, meaning that, nowadays, more people are suffering from mental illness and cardiovascular disease year on year. Therefore, a non-contact measurement of heart rate and heart rate variability (HRV) is proposed to assist physicians in diagnosing symptoms related to mental illness and cardiovascular disease. In this paper, continuous images are obtained by general network cameras with non-contact, facial feature points and regions of interest (ROI) employed to track faces and regional images; HRV parameters were analyzed with the green wavelength of RGB color space. The artifact signal is eliminated by a hybrid algorithm of independent component analysis (ICA) and particle swarming optimization (PSO). Finally, the values of heart rate and HRV are obtained with signal processes of using band-pass filter, fast Fourier transform (FFT), and power spectrum analysis in the time and frequency domains, respectively. The non-contact measurement performance of the proposed method can effectively not only avoid infection doubts and obtain heart rate and HRV quickly, but also provide better physiological parameters, root mean square error (RMSE), and mean absolute percentage error (MAPE), than those of recent published papers.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Real-time estimation of the spectral parameters of Heart Rate Variability
    Kudrynski, Krzysztof
    Strumillo, Pawel
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2015, 35 (04) : 304 - 316
  • [2] Efficient Real-Time Camera Based Estimation of Heart Rate and Its Variability
    Gudi, Amogh
    Bittner, Marian
    Lochmans, Roelof
    van Gemert, Jan
    2019 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW), 2019, : 1570 - 1579
  • [3] Real-time Emotional State Estimation System for Canines Based on Heart Rate Variability
    Hamada, Ryunosuke
    Ohno, Kazunori
    Matsubara, Satoko
    Hoshi, Tatsuya
    Nagasawa, Miho
    Kikusui, Takefumi
    Kubo, Takatomi
    Nakahara, Eri
    Ikeda, Kazushi
    Yamaguchi, Shumpei
    Yamakawa, Toshitaka
    Tadokoro, Satoshi
    2017 IEEE INTERNATIONAL CONFERENCE ON CYBORG AND BIONIC SYSTEMS (CBS), 2017, : 298 - 303
  • [4] Real-Time Evaluation of Heart Rate and Heart Rate Variability Using Microwave Reflectometry
    Mase, Atsushi
    Kogi, Yuichiro
    Maruyama, Totu
    PROCEEDINGS OF THE 2018 IEEE/MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2018, : 160 - 162
  • [5] Real-time evaluation of spectral heart rate variability
    Thong, Tran
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 17 - 20
  • [6] AN INSTRUMENT FOR REAL-TIME SPECTRAL ESTIMATION OF HEART-RATE-VARIABILITY SIGNALS
    BASANO, L
    OTTONELLO, P
    POGGI, A
    ADEZATI, L
    SEMINO, S
    UBALDI, P
    VIVIANI, GL
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1995, 47 (03) : 229 - 236
  • [7] Real-time heart rate variability analysis as a means of hypercapnia detection
    Dituri, Joseph
    Siddiqi, Farhan
    Frisina, Robert
    UNDERSEA AND HYPERBARIC MEDICINE, 2019, 46 (04) : 503 - 507
  • [8] The analysis of heart rate variability using independent component signals
    Teixeira, AR
    Rocha, AP
    Almeida, R
    PROCEEDINGS OF THE SECOND IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2004, : 240 - 243
  • [9] Using independent component analysis to research heart rate variability
    Li, Z. Y.
    Liu, S. R.
    Xie, Z. X.
    Wang, W.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 5532 - 5535
  • [10] Real Time Heart Rate Detection and Heart Rate Variability Calculation
    Paliwal, Sukriti
    Lakshmi, C. Vasantha
    Patvardhan, C.
    2016 IEEE REGION 10 HUMANITARIAN TECHNOLOGY CONFERENCE (R10-HTC), 2016,