Influence of movable inner tube on the charging performance for a horizontal latent thermal energy storage exchanger

被引:1
|
作者
Li, Haotian [1 ]
Dai, Hui [1 ]
Zhou, Shaobin [1 ]
Wang, Wenlong [1 ]
He, Suoying [1 ]
Gao, Ming [1 ]
机构
[1] Shandong Univ, Shandong Engn Res Ctr High Efficiency Energy Stora, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
关键词
Latent thermal energy storage exchanger; Movable inner tube; Charging performance; Movable scheme; Numerical simulation; PHASE-CHANGE; OPTIMIZATION;
D O I
10.1016/j.est.2023.109831
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The charging performance of horizontal shell-and-tube latent thermal storage exchangers is significantly influenced by the position of the inner tube. However, the underlying mechanisms of the effect of inner tube movement on the charging performance remain unclear. Based on this, this paper proposed a horizontal shelland-tube latent thermal energy storage exchanger whose inner tube is movable or Heat Exchanger with Movable Tube (MTHX), the two-dimensional simulation model of the MTHX was established, and the influence of the inner tube movement direction, speed, and range on the charging performance was studied, and finally this study obtained an optimized inner tube movement scheme for the charging process. The results indicate that the exchanger exhibits improved charging performance when the inner tube lies in the lower hemisphere region and moves up and down along the radius direction. Furthermore, increasing the velocity of inner tube movement enhances the charging rate. Additionally, the impact of the inner tube movement range on the charging performance depends on the direction of the movement. Moreover, compared to traditional horizontal shell-andtube latent thermal storage exchangers, the implementation of the optimized inner tube movement scheme results in a 78.88 % reduction in charging time and a remarkable 348.71 % increase in average charging rate. This research presents novel directions for optimizing the charging performance of horizontal shell-and-tube latent thermal storage exchangers, thereby laying the foundation for the engineering application. The findings hold significant theoretical implications and engineering value.
引用
下载
收藏
页数:16
相关论文
共 50 条
  • [1] Simulation study on charging performance of the latent energy storage heat exchanger with a novel conical inner tube
    Dai, Hui
    Wang, Yuhang
    Wang, Nini
    Li, Haotian
    Gao, Ming
    JOURNAL OF ENERGY STORAGE, 2022, 56
  • [2] Influence of inner tube shapes on the charging and discharging performance for the latent heat thermal storage exchangers
    Zhou, Shaobin
    Dai, Hui
    Gao, Ming
    He, Suoying
    Niu, Pingping
    Shi, Yuetao
    Qi, Jianhui
    Sun, Fengzhong
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 154
  • [3] Influence of the inner tube rotation and translation associated movement on the charging performance for the latent heat thermal energy storage exchangers
    Shandong Engineering Research Center for High-efficiency Energy Storage and Hydrogen Energy Utilization, School of Energy and Power Engineering, Shandong University, Shandong, Jinan
    250061, China
    不详
    250061, China
    不详
    518057, China
    不详
    276800, China
    Renew. Energy,
  • [4] A charging time energy fraction method for evaluating the performance of a latent thermal energy storage heat exchanger
    Beyne, Wim
    Couvreur, Kenny
    Jollyn, Ilya T'
    Tassenoy, Robin
    Lecompte, Steven
    De Paepe, Michel
    APPLIED THERMAL ENGINEERING, 2021, 195
  • [5] Investigation of charging and discharging characteristics of a horizontal conical shell and tube latent thermal energy storage device
    Sodhi, Gurpreet Singh
    Jaiswal, Abhishek Kumar
    Vigneshwaran, K.
    Muthukumar, P.
    ENERGY CONVERSION AND MANAGEMENT, 2019, 188 : 381 - 397
  • [6] Effect of inner-tube spacing on charging and discharging performance of latent energy storage heat exchangers
    Li, Haotian
    Wang, Nini
    He, Suoying
    Gao, Ming
    APPLIED THERMAL ENGINEERING, 2022, 216
  • [7] Simulation study on the effect of fins on the heat transfer performance of horizontal dual-inner-tube latent thermal energy storage heat exchangers
    Li, Haotian
    Wang, Nini
    Zhao, Bin
    Feng, Huimin
    Han, Kuihua
    He, Suoying
    Gao, Ming
    JOURNAL OF ENERGY STORAGE, 2022, 49
  • [8] Numerical analysis of the influence of geometry parameters on charging and discharging performance of shell-and-tube latent thermal energy storage with longitudinal fins
    Kirincic, Mateo
    Trp, Anica
    Lenic, Kristian
    Torbarina, Fran
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [9] The effect of conical shell and converging/diverging tube on the charging performance of shell and tube latent heat thermal energy storage system
    Ghazani, A. Shafiei
    Gholamzadeh, A.
    JOURNAL OF ENERGY STORAGE, 2023, 65
  • [10] Thermal performance of a novel dual-PCM latent thermal energy storage unit with an inner spiral coil tube
    Zhang, Kun
    Yu, Ze-Wen
    Song, Ke-Wei
    Wang, Liang -Bi
    JOURNAL OF ENERGY STORAGE, 2024, 88