Three-Dimensional Numerical Modeling and Analysis for the Municipal Solid-Waste Incineration of the Grate Furnace for Particulate-Matter Generation

被引:17
|
作者
Liang, Yongqi [1 ,2 ]
Tang, Jian [1 ,2 ]
Xia, Heng [1 ,2 ]
Aljerf, Loai [3 ]
Gao, Bingyin [4 ]
Akele, Mulugeta Legesse [5 ,6 ]
机构
[1] Beijing Univ Technol, Fac Informat Technol, Beijing 100124, Peoples R China
[2] Beijing Lab Smart Environm Protect, Beijing 100124, Peoples R China
[3] Damascus Univ, Fac Sci, Dept Chem, Key Lab Organ Ind, POB 30621, Damascus, Syria
[4] Beijing GaoAnTun Waste Energy Co Ltd, Beijing 100024, Peoples R China
[5] Univ Gondar, Coll Nat & Computat Sci, Dept Chem, POB 196, Gondar, Ethiopia
[6] Univ Melbourne, Fac Sci, Sch Chem, Melbourne, Vic 3010, Australia
关键词
municipal solid waste incineration (MSWI); PM concentration; 3D numerical modeling; single factor analysis; orthogonal experiments; optimal control; FLY-ASH; SIMULATION; PARTICLES; ADHESION; WALL;
D O I
10.3390/su151612337
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A 3D numerical model of the municipal solid waste incineration (MSWI) process was constructed based on a grate furnace with a daily processing capacity of 800 tons. Fluent was used for analyzing key factors affecting the concentration and diffusion level of particulate matter (PM). According to the actual MSWI plant working condition, a 3D model of the incinerator and the waste heat boiler has been constructed under benchmarks. Key factors affecting PM generation were determined by combining mechanistic knowledge and experts' experience. They were the combustion temperature of solid phase municipal solid waste (MSW), the wall's PM collision mode, and the second baffle length. Subsequently, the process of resolving the 3D numerical model was delineated. Then, a univariate analysis of the aforementioned 3D model was conducted for the three pivotal factors mentioned above. Conclusively, the effect of the important factors on the number of particles at the outflow of the incinerator was analyzed via orthogonal experiments to obtain the optimal combination. PM concentration initially diminished and then rose with the increased combustion temperature of the solid-phase MSW. Furthermore, a noteworthy reduction in PM concentration was observed when the second baffle length was 12.45-12.95 m. The greatest influence on the PM concentration of the outlet was posed by the wall's PM collision mode, followed by the second baffle length. The appropriate adjustment of the combustion temperature of the solid-phase MSW, selection of wall materials, and design of the second baffle length were beneficial for diminishing PM concentration and ensuring long-term stable operation of the MSWI process. The combinative optimality of the three key factors was acquired via orthogonal experiments, which proved the subsequent optimal control of PM concentration at the outlet.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Three-dimensional combustion modeling in municipal solid-waste incinerator
    Chen, KS
    Tsai, YJ
    Lou, JC
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 1999, 125 (02) : 166 - 174
  • [2] Numerical Simulation Method of Municipal Solid Waste Incineration Process Based on Grate Furnace: A Survey
    Zhuang, Jiabin
    Tang, Jian
    Jia, Mingying
    Zhu, Hongjun
    [J]. PROCEEDINGS OF THE 39TH CHINESE CONTROL CONFERENCE, 2020, : 1156 - 1161
  • [3] Numerical simulation of dioxin emission concentration in grate furnace incineration processes for municipal solid waste
    Chen, Jiakun
    Tang, Jian
    Xia, Heng
    Qiao, Junfei
    [J]. Huagong Jinzhan/Chemical Industry and Engineering Progress, 2023, 42 (02): : 1061 - 1072
  • [4] Numerical simulation of municipal solid waste incineration in a moving-grate furnace and the effect of waste moisture content
    Bin Yang, Yao
    Sharifi, Vida N.
    Swithenbank, Jim
    [J]. PROGRESS IN COMPUTATIONAL FLUID DYNAMICS, 2007, 7 (05): : 261 - 273
  • [5] Failure analysis of grate in a municipal solid waste incineration plant
    Kochmanska, Agnieszka Elzbieta
    Kochmanski, Pawel
    [J]. ENGINEERING FAILURE ANALYSIS, 2024, 165
  • [6] Numerical Simulation Model of Dioxin Production in Grate Furnace-based Municipal Solid Waste Incineration Process
    Guo, Zihao
    Tang, Jian
    Qiao, Junfei
    [J]. 2018 37TH CHINESE CONTROL CONFERENCE (CCC), 2018, : 3502 - 3507
  • [7] Simulation of co-incineration of sewage sludge with municipal solid waste in a grate furnace incinerator
    Lin, Hai
    Ma, Xiaoqian
    [J]. WASTE MANAGEMENT, 2012, 32 (03) : 561 - 567
  • [8] Simulating municipal solid waste incineration with a DEM/CFD method - Influences of waste properties, grate and furnace design
    Wissing, F.
    Wirtz, S.
    Scherer, V.
    [J]. FUEL, 2017, 206 : 638 - 656
  • [9] CHEMICAL INPUT-OUTPUT-ANALYSIS OF MUNICIPAL SOLID-WASTE INCINERATION
    HOCKING, MB
    [J]. JOURNAL OF ENVIRONMENTAL SYSTEMS, 1975, 5 (03): : 163 - 183
  • [10] Comprehensive review on mechanism analysis and numerical simulation of municipal solid waste incineration process based on mechanical grate
    Zhuang, Jiabin
    Tang, Jian
    Aljerf, Loai
    [J]. FUEL, 2022, 320