A Biologically Inspired Cross-Type Ankle-Foot Exotendon: Assisting Plantarflexion Moment and Movement Stability

被引:1
|
作者
Liu, Yuyao [1 ]
Sun, Ronglei [1 ]
Li, Ying [1 ]
Zhang, Miao [1 ]
Zou, Kaijie [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Mech Sci & Engn, State Key Lab Intelligent Mfg Equipment & Technol, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Cross-type double-cable-driven; Ankle-foot exotendon; Exoskeleton; Bionic design; Muscle arrangement; EXOSKELETON;
D O I
10.1007/s42235-023-00398-y
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cable-driven ankle-foot exoskeletons have attracted numerous researchers over the previous decade. The assistive forces of most exoskeletons pulled the back bottom of the shoes, across talocrural and subtalar joints. The talocrural joint is inherently mediolateral unstable at the plantarflexion position due to its sliding mortise structure, while the subtalar joint allows inversion/eversion. In this paper, a biologically inspired cross-type double-cable-driven ankle-foot exotendon was proposed to assist not only the plantarflexion moment but also the movement stability. The novel structure was bio-inspired by the behind-calf anatomically symmetric layout and under-foot cross-configuration of the ankle-foot muscles. To examine the combined functions, we conducted a forward pelvis perturbed standing experiment on five subjects without and with exotendon assistance and recorded the biomechanical data. Compared to the unpowered condition, the biological ankle plantarflexion moment was reduced by 39% with 0.1 Nm/kg exotendon assistance for one leg. Besides, the forward margin of stability was increased by 17% during the late perturbation period, which indicated the improvement of balance in the sagittal plane. In addition, the standard deviation of the lateral CoP and three-dimensional marker trajectories for the ankle condylar and heel all descended, which provided evidence for ankle-foot stability improvement. The results suggested that the proposed biological exotendon can provide the compound ankle-foot assistance, reducing plantarflexion moment and improving movement stability.
引用
收藏
页码:2633 / 2645
页数:13
相关论文
共 9 条
  • [1] A Biologically Inspired Cross-Type Ankle–Foot Exotendon: Assisting Plantarflexion Moment and Movement Stability
    Yuyao Liu
    Ronglei Sun
    Ying Li
    Miao Zhang
    Kaijie Zou
    Journal of Bionic Engineering, 2023, 20 : 2633 - 2645
  • [2] Biologically Inspired Design and Development of a Variable Stiffness Powered Ankle-Foot Prosthesis
    Agboola-Dobson, Alexander
    Wei, Guowu
    Ren, Lei
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2019, 11 (04):
  • [3] Design and Characterization of a Biologically Inspired Quasi-Passive Prosthetic Ankle-Foot
    Mooney, Luke M.
    Lai, Cara H.
    Rouse, Elliott J.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1611 - 1617
  • [4] The impact of ankle-foot orthosis's plantarflexion resistance on knee adduction moment in people with chronic stroke
    Kobayashi, Toshiki
    Hunt, Grace
    Orendurff, Michael S.
    Gao, Fan
    Singer, Madeline L.
    Foreman, K. Bo
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2022, 46 (06) : 560 - 565
  • [5] A Compliant 2-DoF Ankle-Foot System for a Biologically Inspired Humanoid Robot
    Rodriguez-Cianca, David
    Weckx, Maarten
    Torricelli, Diego
    Gonzalez, Jose
    Lefeber, Dirk
    Luis Pons, Jose
    2015 IEEE-RAS 15TH INTERNATIONAL CONFERENCE ON HUMANOID ROBOTS (HUMANOIDS), 2015, : 264 - 269
  • [6] The effect of changing plantarflexion resistive moment of an articulated ankle-foot orthosis on ankle and knee joint angles and moments while walking in patients post stroke
    Kobayashi, Toshiki
    Singer, Madeline L.
    Orendurff, Michael S.
    Gao, Fan
    Daly, Wayne K.
    Foreman, K. Bo
    CLINICAL BIOMECHANICS, 2015, 30 (08) : 775 - 780
  • [7] Stiffness control in posterior-type plastic ankle-foot orthoses: Effect of ankle trimline .1. A device for measuring ankle moment
    Sumiya, T
    Suzuki, Y
    Kasahara, T
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1996, 20 (02) : 129 - 131
  • [8] Effects of a microprocessor-controlled ankle-foot unit on energy expenditure, quality of life, and postural stability in persons with transtibial amputation: An unblinded, randomized, controlled, cross-over study
    Colas-Ribas, Christophe
    Martinet, Noel
    Audat, Gaelle
    Bruneau, Antoine
    Paysant, Jean
    Abraham, Pierre
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2022, 46 (06) : 541 - 548
  • [9] Effectiveness of elastic band-type ankle-foot orthoses on postural control in poststroke elderly patients as determined using combined measurement of the stability index and body weight-bearing ratio
    Kim, Jong Hyun
    Sim, Woo Sang
    Won, Byeong Hee
    CLINICAL INTERVENTIONS IN AGING, 2015, 10 : 1839 - 1847