A quantitative framework for patient-specific collision detection in proton therapy

被引:0
|
作者
Northway, Stephen K. [1 ,2 ]
Vallejo, Bailey M. [1 ,2 ]
Liu, Lawrence [1 ,2 ]
Hansen, Emily E. [1 ,2 ]
Tang, Shikui [3 ]
Mah, Dennis [4 ]
Macewan, Iain J. [1 ,2 ]
Urbanic, James J. [1 ,2 ]
Chang, Chang [1 ,2 ,5 ]
机构
[1] Univ Calif San Diego, Dept Radiat Med & Appl Sci, La Jolla, CA USA
[2] Calif Protons Canc Therapy Ctr, San Diego, CA USA
[3] Texas Ctr Proton Therapy, Irving, TX USA
[4] Procure Proton Therapy Ctr, Somerset, NJ USA
[5] Univ Calif San Diego, Dept Radiat Med & Appl Sci, 9730 Summers Ridge Rd, San Diego, CA 92121 USA
来源
关键词
collision detection; lateral penumbra; proton therapy; GAUSSIAN-BEAM MODEL; AVOIDANCE; PREDICTION; SIMULATION; PREVENTION; SCATTERING; SOFTWARE;
D O I
10.1002/acm2.14247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundBeam modifying accessories for proton therapy often need to be placed in close proximity of the patient for optimal dosimetry. However, proton treatment units are larger in size and as a result the planned treatment geometry may not be achievable due to collisions with the patient. A framework that can accurately simulate proton treatment geometry is desired.PurposeA quantitative framework was developed to model patient-specific proton treatment geometry, minimize air gap, and avoid collisions.MethodsThe patient's external contour is converted into the International Electrotechnique Commission (IEC) gantry coordinates following the patient's orientation and each beam's gantry and table angles. All snout components are modeled by three-dimensional (3D) geometric shapes such as columns, cuboids, and frustums. Beam-specific parameters such as isocenter coordinates, snout type and extension are used to determine if any point on the external contour protrudes into the various snout components. A 3D graphical user interface is also provided to the planner to visualize the treatment geometry. In case of a collision, the framework's analytic algorithm quantifies the maximum protrusion of the external contour into the snout components. Without a collision, the framework quantifies the minimum distance of the external contour from the snout components and renders a warning if such distance is less than 5 cm.ResultsThree different snout designs are modeled. Examples of potential collision and its aversion by snout retraction are demonstrated. Different patient orientations, including a sitting treatment position, as well as treatment plans with multiple isocenters, are successfully modeled in the framework. Finally, the dosimetric advantage of reduced air gap enabled by this framework is demonstrated by comparing plans with standard and reduced air gaps.ConclusionImplementation of this framework reduces incidence of collisions in the treatment room. In addition, it enables the planners to minimize the air gap and achieve better plan dosimetry.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] An unsupervised patient-specific metal artifact reduction framework for proton therapy
    Chang, Chih-Wei
    Lei, Yang
    Charyyev, Serdar
    Leng, Shuai
    Yoon, Tim
    Zhou, Jun
    Yang, Xiaofeng
    Lin, Liyong
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [2] Design of a 3D patient-specific collision avoidance virtual framework for half-gantry proton therapy system
    Dougherty, Jingjing M.
    Whitaker, Thomas J.
    Mundy, Daniel W.
    Tryggestad, Erik J.
    Beltran, Chris J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):
  • [3] Tolerance design of patient-specific range QA using the DMAIC framework in proton therapy
    Rah, Jeong-Eun
    Shin, Dongho
    Manger, Ryan P.
    Kim, Tae Hyun
    Oh, Do Hoon
    Kim, Dae Yong
    Kim, Gwe-Ya
    MEDICAL PHYSICS, 2018, 45 (02) : 520 - 528
  • [4] Patient-Specific Collision Detection Package Using Surface Imaging
    Padilla, L.
    Pearson, E. A.
    Pelizzari, C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S827 - S827
  • [5] Evaluation of Radioactivity Induced by Patient-specific Devices in Proton Therapy
    Lee, Sang Hoon
    Cho, Sungkoo
    You, Seung Hoon
    Shin, Dongho
    Park, Sung Yong
    Lee, Se Byeong
    Kwak, Jungwon
    Woo, Jong-Kwan
    Kim, Dae Hyun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (01) : 125 - 128
  • [6] Evaluation of radioactivity induced by patient-specific devices in proton therapy
    Sang Hoon Lee
    Sungkoo Cho
    Seung Hoon You
    Dongho Shin
    Sung Yong Park
    Se Byeong Lee
    Jungwon Kwak
    Jong-Kwan Woo
    Dae Hyun Kim
    Journal of the Korean Physical Society, 2012, 60 : 125 - 128
  • [7] Induced radioactivity in a patient-specific collimator used in proton therapy
    Cesana, Alessandra
    Mauro, Egidio
    Silari, Marco
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (13): : 2272 - 2280
  • [8] Patient-specific collision zones for 4π trajectory optimized radiation therapy
    Northway, Cassidy
    Lincoln, John David
    Little, Brian
    Syme, Alasdair
    Thomas, Christopher G.
    MEDICAL PHYSICS, 2022, 49 (03) : 1407 - 1416
  • [9] Patient-specific stopping power calibration for proton therapy based on proton radiographic images
    Largent, A.
    Barateau, A.
    Nunes, J.
    Lafond, C.
    Greer, P. B.
    Dowling, J. A.
    Saint-Jalmes, H.
    Acosta, O.
    De Crevoisier, R.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S555 - S556
  • [10] Efficient double-scattering proton therapy with a patient-specific bolus
    Zou, Wei
    Burgdorf, Brendan
    Yue, Ning J.
    Yin, Lingshu
    Zhang, Miao
    Khan, Atif
    Jabbour, Salma K.
    McDonough, James
    Dong, Lei
    Teo, Boon-Keng Kevin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 1 - 6