Indirect Georeferencing in Terrestrial Laser Scanning: One-Step and Two-Step Approaches

被引:1
|
作者
Pham, Dung Trung [1 ]
Nguyen, Long Quoc [1 ,2 ]
Le, Tinh Duc [1 ]
Tran, Hai Thanh [1 ]
机构
[1] Hanoi Univ Min & Geol, Fac Geomat & Land Adm, Hanoi 100000, Vietnam
[2] Hanoi Univ Min & Geol, Innovat Sustainable & Responsible Min ISRM Res Gr, Hanoi 100000, Vietnam
关键词
Terrestrial laser scanner; Indirect georeferencing; One-step approach; Two-step approach;
D O I
10.1007/978-3-031-20463-0_11
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The georeferencing procedure is to transform geospatial data from a local coordinate system to a global coordinate system, notably geodetic coordinate system on a geocentric datum. In this paper, both the one-step and two-step approaches of indirect georeferencing of 3D point cloud from terrestrial laser scanning are investigated. The georeferencing procedure is applied to a real dataset acquired by a Faro Focus(3M) X130 laser scanner and the control points and targets are measured by total station TS06 plus. Five scenarios are used for the comparison between the one-step and two-step approaches in terms of both accuracies of the 3D model and time consumption. Besides, the influence of the target's configuration on the 3D model is evaluated by changing either the number or the position of the targets. The results suggest that the 3D model's accuracies when using both the one-step and two-step approaches of indirect georeferencing are comparable. Additionally, the target's configuration greatly affects the 3D model with the one-step approach of indirect georeferencing. From the rigorous analyses of the benefit and drawbacks of both approaches evaluated on the real dataset, the paper significantly contributes to the indirect georeferencing procedure when transforming the 3D point cloud acquired from terrestrial laser scanning into the geodetic coordinate system.
引用
收藏
页码:171 / 186
页数:16
相关论文
共 50 条
  • [1] On the Accuracy of the One-step UKF and the Two-step UKF
    Goel, Ankit
    Bernstein, Dennis S.
    2022 IEEE 61ST CONFERENCE ON DECISION AND CONTROL (CDC), 2022, : 5375 - 5380
  • [2] One-step and two-step estimation in SFA models
    Schmidt, Peter
    JOURNAL OF PRODUCTIVITY ANALYSIS, 2011, 36 (02) : 201 - 203
  • [3] One-step, two-step regulation of therapeutic genes
    Webster, KA
    SCIENTIST, 1999, 13 (09): : 13 - 13
  • [4] One-step and two-step estimation in SFA models
    Peter Schmidt
    Journal of Productivity Analysis, 2011, 36 : 201 - 203
  • [5] Bond strengths of two-step and one-step adhesive systems
    Kelsey, WP
    Triolo, PT
    Blankenau, RJ
    Kelsey, MN
    Hauser, D
    Ortmeier, C
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1922 - 1922
  • [6] REDO GASTRIC BYPASS, A ONE-STEP OR TWO-STEP PROCEDURE?
    Guelinckx, N.
    Martijnse, I.
    Maring, J.
    Langenhoff, B.
    Martijnse, I.
    OBESITY SURGERY, 2014, 24 (07) : 1027 - 1027
  • [7] Behaviour of combustion waves in one-step and two-step models
    Sharples, J. J.
    Gubernov, V. V.
    Sidhu, H. S.
    Towers, I. N.
    Kolobov, A. V.
    Polezhaev, A. A.
    18TH WORLD IMACS CONGRESS AND MODSIM09 INTERNATIONAL CONGRESS ON MODELLING AND SIMULATION: INTERFACING MODELLING AND SIMULATION WITH MATHEMATICAL AND COMPUTATIONAL SCIENCES, 2009, : 4453 - 4459
  • [8] Redo Laparoscopic Gastric Bypass: One-Step or Two-Step Procedure?
    Theunissen, Caroline M. J.
    Guelinckx, Nele
    Maring, John K.
    Langenhoff, Barbara S.
    OBESITY SURGERY, 2016, 26 (11) : 2675 - 2682
  • [9] Redo Laparoscopic Gastric Bypass: One-Step or Two-Step Procedure?
    Caroline M. J. Theunissen
    Nele Guelinckx
    John K. Maring
    Barbara S. Langenhoff
    Obesity Surgery, 2016, 26 : 2675 - 2682
  • [10] Comparison one-step procedure with two-step procedure in percutaneous nephrolithotomy
    Chen, Szu-Han
    Wu, Wen-Jeng
    Chou, Yii-Her
    Yeh, Hsin-Chih
    Tsai, Chia-Chun
    Chueh, Kuang-Shun
    Hou, Nien-Ting
    Chiu, Siou-Jin
    Tu, Hung-Pin
    Li, Ching-Chia
    UROLITHIASIS, 2014, 42 (02) : 121 - 126