Nanoscale imaging of Fe-rich inclusions in single-crystal zircon using X-ray ptycho-tomography

被引:1
|
作者
Kuppili, Venkata S. C. [1 ,4 ]
Ball, Matthew [1 ]
Batey, Darren [2 ]
Dodds, Kathryn [1 ]
Cipiccia, Silvia [2 ,5 ]
Wanelik, Kaz [2 ]
Fu, Roger [3 ]
Rau, Christoph [2 ]
Harrison, Richard J. [1 ]
机构
[1] Univ Cambridge, Dept Earth Sci, Downing St, Cambridge CB2 3EQ, England
[2] Diamond Light Source, Harwell Campus, Didcot OX11 0DE, England
[3] Harvard Univ, Dept Earth & Planetary Sci, Cambridge, MA 02138 USA
[4] Univ Saskatchewan, Canadian Light Source, 44 Innovat Blvd, Saskatoon, SK S7N 2V3, Canada
[5] UCL, Dept Med Phys & Biomed Engn, Gower St, London WC1E 6BT, England
关键词
AMINO-ACID CONTENT; JACK HILLS; COMPUTED-TOMOGRAPHY; BISHOP TUFF; QUARTZITE COBBLES; DUSTY OLIVINE; SOLAR-WIND; MAGNETITE; MICROTOMOGRAPHY; MAGNETIZATIONS;
D O I
10.1038/s41598-024-55846-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We apply X-ray ptycho-tomography to perform high-resolution, non-destructive, three-dimensional (3D) imaging of Fe-rich inclusions in paleomagnetically relevant materials (zircon single crystals from the Bishop Tuff ignimbrite). Correlative imaging using quantum diamond magnetic microscopy combined with X-ray fluorescence mapping was used to locate regions containing potential ferromagnetic remanence carriers. Ptycho-tomographic reconstructions with voxel sizes 85 nm and 21 nm were achievable across a field-of-view > 80 mu m; voxel sizes as small as 5 nm were achievable over a limited field-of-view using local ptycho-tomography. Fe-rich inclusions 300 nm in size were clearly resolved. We estimate that particles as small as 100 nm-approaching single-domain threshold for magnetite-could be resolvable using this "dual-mode" methodology. Fe-rich inclusions (likely magnetite) are closely associated with apatite inclusions that have no visible connection to the exterior surface of the zircon (e.g., via intersecting cracks). There is no evidence of radiation damage, alteration, recrystallisation or deformation in the host zircon or apatite that could provide alternative pathways for Fe infiltration, indicating that magnetite and apatite grew separately as primary phases in the magma, that magnetite adhered to the surfaces of the apatite, and that the magnetite-coated apatite was then encapsulated as primary inclusions within the growing zircon. Rarer examples of Fe-rich inclusions entirely encapsulated by zircon are also observed. These observations support the presence of primary inclusions in relatively young and pristine zircon crystals. Combining magnetic and tomography results we deduce the presence of magnetic carriers that are in the optimal size range for carrying strong and stable paleomagnetic signals but that remain below the detection limits of even the highest-resolution X-ray tomography reconstructions. We recommend the use of focused ion beam nanotomography and/or correlative transmission electron microscopy to directly confirm the presence of primary magnetite in the sub 300 nm range as a necessary step in targeted paleomagnetic workflows.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Nanoscale imaging of Fe-rich inclusions in single-crystal zircon using X-ray ptycho-tomography
    Venkata S. C. Kuppili
    Matthew Ball
    Darren Batey
    Kathryn Dodds
    Silvia Cipiccia
    Kaz Wanelik
    Roger Fu
    Christoph Rau
    Richard J. Harrison
    Scientific Reports, 14
  • [2] Robust X-Ray Phase Ptycho-Tomography
    Venkatakrishnan, Singanallur V.
    Farmand, Maryam
    Yu, Young-Sang
    Majidi, Hasti
    van Benthem, Klaus
    Marchesini, Stefano
    Shapiro, David A.
    Hexemer, Alexander
    IEEE SIGNAL PROCESSING LETTERS, 2016, 23 (07) : 944 - 948
  • [3] An X-ray ptycho-tomography model of 'Seeing order in "amorphous" materials'
    Li, Peng
    Batey, Darren
    Rodenburg, John
    ULTRAMICROSCOPY, 2019, 203 : 88 - 94
  • [4] Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time
    Iksung Kang
    Ziling Wu
    Yi Jiang
    Yudong Yao
    Junjing Deng
    Jeffrey Klug
    Stefan Vogt
    George Barbastathis
    Light: Science & Applications, 12
  • [5] Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time
    Kang, Iksung
    Wu, Ziling
    Jiang, Yi
    Yao, Yudong
    Deng, Junjing
    Klug, Jeffrey
    Vogt, Stefan
    Barbastathis, George
    LIGHT-SCIENCE & APPLICATIONS, 2023, 12 (01)
  • [6] SIMULTANEOUS 3D X-RAY PTYCHO-TOMOGRAPHY WITH GRADIENT DESCENT
    Barutcu, Semih
    Ruiz, Pablo
    Schiffers, Florian
    Aslan, Selin
    Gursoy, Doga
    Cossairt, Oliver
    Katsaggelos, Aggelos K.
    2020 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2020, : 96 - 100
  • [8] X-Ray Tomography Investigation of Fe-rich Intermetallics in AlSi Alloys
    Mikolajczak, P.
    Ratke, L.
    ARCHIVES OF FOUNDRY ENGINEERING, 2013, 13 (04) : 79 - 82
  • [9] SINGLE-CRYSTAL X-RAY DIFFRACTION
    Gurzhiy, Vladislav V.
    ADVANCED MATERIALS & PROCESSES, 2020, 178 (01): : 32 - 34
  • [10] FORMATION AND STABILITY OF FE-RICH PRECIPITATES IN DILUTE ZR(FE) SINGLE-CRYSTAL ALLOYS
    ZOU, H
    HOOD, GM
    ROY, JA
    SCHULTZ, RJ
    METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1994, 25 (07): : 1359 - 1365