Influence of ultrasound transmit frequency on measurement of global longitudinal strain on 2D speckle tracking echocardiography

被引:0
|
作者
Iwakura, Katsuomi [1 ]
Onishi, Toshinari [2 ]
Koyama, Yasushi [1 ]
Iwamoto, Mutsumi [1 ]
Watanabe, Satoshi [1 ]
Tanaka, Koji [1 ]
Hirao, Yuko [1 ]
Tanaka, Nobuaki [1 ]
Sumiyoshi, Akinori [1 ]
Okada, Masato [1 ]
Tanaka, Kota [1 ]
Harada, Shinichi [1 ]
Watanabe, Heitaro [1 ]
Okamura, Atsunori [1 ]
机构
[1] Sakurabashi Watanabe Hosp, Div Cardiol, 2-4-32 Umeda,Kita Ku, Osaka, Osaka 5300001, Japan
[2] Sakai City Med Ctr, Dept Cardiovasc Med, 1-1-1 Ebaraji Cho,Nishi Ku, Sakai, Osaka 5938304, Japan
来源
SCIENTIFIC REPORTS | 2023年 / 13卷 / 01期
关键词
VENTRICULAR EJECTION FRACTION; ALL-CAUSE MORTALITY; HEART-FAILURE; EUROPEAN ASSOCIATION; CONSENSUS DOCUMENT; DIFFERENT VENDORS; SYSTOLIC FUNCTION; EXPERT CONSENSUS; PROGNOSTIC VALUE; IMAGE QUALITY;
D O I
10.1038/s41598-023-49664-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The reproducibility of longitudinal strain measured by 2D speckle tracking echocardiography (2DSTE) may be affected by ultrasound settings. This study investigated the effect of transmit ultrasound frequency on global longitudinal strain (GLS) by 2DSTE. Apical, 2- and 4-chamber, and long-axis views were obtained in consecutive 162 patients using Philips ultrasound devices. Three different frequency presets were used sequentially: high resolution (HRES, 1.9 to 2.1 MHz), general (HGEN, 1.6 to 1.8 MHz), and penetration mode (HPEN, 1.3 to 1.6 MHz). GLS values were determined for each preset using the Philips Q-station software, resulting in GLS-HRES, GLS-HGEN, and GLS-HPEN. Among the 151 patients with successfully measured GLS, a significant difference in GLS was observed among the three presets (p < 0.0001). GLS-HRES (- 17.9 +/- 4.4%) showed a slightly smaller magnitude compared to GLS-HGEN (- 18.8 +/- 4.5%, p < 0.0001) and GLS-HPEN (- 18.8 +/- 4.5%, p < 0.0001), with absolute differences of 1.1 +/- 1.0% and 1.1 +/- 1.2%, respectively. This variation in GLS with frequency was evident in patients with both optimal (n = 104) and suboptimal (n = 47) image quality and remained consistent regardless of ultrasound devices, ischemic etiology, or ejection fraction. In conclusion, ultrasound frequency had only a modest effect on GLS measurements. GLS may be reliably assessed in most cases regardless of the ultrasound frequency used.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Influence of ultrasound transmit frequency on measurement of global longitudinal strain on 2D speckle tracking echocardiography
    Katsuomi Iwakura
    Toshinari Onishi
    Yasushi Koyama
    Mutsumi Iwamoto
    Satoshi Watanabe
    Koji Tanaka
    Yuko Hirao
    Nobuaki Tanaka
    Akinori Sumiyoshi
    Masato Okada
    Kota Tanaka
    Shinichi Harada
    Heitaro Watanabe
    Atsunori Okamura
    Scientific Reports, 13 (1)
  • [2] Effect of Ultrasound Transducer Frequency on Longitudinal Strain Measurement by 2d Speckle Tracking Echocardiography
    Iwakura, Katsuomi
    Okamura, Atsunori
    Koyama, Yasushi
    Inoue, Koichi
    Iwamoto, Mutsumi
    Nagai, Hiroyuki
    Hirao, Yuko
    Tanaka, Koji
    Oka, Takafumi
    Tanaka, Nobuaki
    Ninomiya, Yuichi
    Okada, Masato
    Sumiyoshi, Akinori
    Inoue, Hiroyuki
    Tanaka, Kota
    Takayasu, Kohtaro
    Fujii, Kenshi
    CIRCULATION, 2018, 138
  • [3] Prognostic Value of LV Global Longitudinal Strain by 2D and 3D Speckle-Tracking Echocardiography in Patients With HFpEF
    Lin, Yixia
    Xie, Mingxing
    Zhang, Li
    Zhang, Yanting
    Zhang, Peige
    Chen, Xin
    Ji, Mengmeng
    Gao, Lang
    He, Qing
    Wu, Zhenni
    Yang, Yali
    Li, Yuman
    CIRCULATION-CARDIOVASCULAR IMAGING, 2025, 18 (02)
  • [4] LEFT VENTRICULAR LONGITUDINAL 2D STRAIN BY SPECKLE TRACKING
    El-Shanshory, Mohamed
    Tolba, Osama
    Abdel-Hafez, Maher
    PEDIATRIC BLOOD & CANCER, 2013, 60 : S26 - S26
  • [5] Longitudinal strain measurement by 3D modelling from cine CMR: feasibility and comparison to 2D speckle tracking echocardiography
    Zhao, D.
    Quill, G. M.
    Gilbert, K.
    Wang, V. Y.
    Sutton, T.
    Lowe, B. S.
    Legget, M. E.
    Doughty, R. N.
    Young, A. A.
    Nash, M. P.
    EUROPEAN HEART JOURNAL, 2021, 42 : 266 - 266
  • [6] Impact of 2D echocardiography image quality on longitudinal global strain by speckle tracking for assessing left ventricular systolic function
    Macron, L.
    Nahum, J.
    Bensaid, A.
    Mitchell-Heggs, L.
    Deux, J. F.
    Dubois-Rande, J. L.
    Monin, J. L.
    Gueret, P.
    Lim, P.
    EUROPEAN HEART JOURNAL, 2010, 31 : 1064 - 1064
  • [7] Value of 3D Versus 2D Speckle-Tracking Echocardiography for RV Strain Measurement
    Li, Yuman
    Wan, Xiaojing
    Xiao, Qiuyue
    Zhang, Yanting
    Sun, Wei
    Xie, Yuji
    Zeng, Qingyu
    Sun, Zhenxing
    Yang, Yali
    Wang, Jing
    Lv, Qing
    Shi, Heshui
    Zhang, Li
    Xie, Mingxing
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (09) : 2056 - 2058
  • [8] Evaluation of the left venticular systolic function with the measurement of global longitudinal strain by Speckle tracking echocardiography in anaphylaxis
    Demir, Semra
    Atici, Adem
    Coskun, Raif
    Olgac, Muge
    Unal, Derya
    Sarikaya, Remzi
    Gelincik, Asli
    Colakoglu, Bahattin
    Oflaz, Huseyin
    Sonsoz, Mehmet Rasih
    Buyukorturk, Suna
    ASIA PACIFIC ALLERGY, 2018, 8 (04)
  • [9] Segmental and global longitudinal strain measurement by 2-dimensional speckle tracking echocardiography in severe rheumatic mitral stenosis
    Samira Mehrabi-Pari
    Sepehr Nayebirad
    Akbar Shafiee
    Ahmad Vakili-Basir
    Reza Hali
    Mojgan Ghavami
    Arash Jalali
    BMC Cardiovascular Disorders, 23
  • [10] Segmental and global longitudinal strain measurement by 2-dimensional speckle tracking echocardiography in severe rheumatic mitral stenosis
    Mehrabi-Pari, Samira
    Nayebirad, Sepehr
    Shafiee, Akbar
    Vakili-Basir, Ahmad
    Hali, Reza
    Ghavami, Mojgan
    Jalali, Arash
    BMC CARDIOVASCULAR DISORDERS, 2023, 23 (01)