Myocardial scar detection in free-breathing Dixon-based fat- and water-separated 3D inversion recovery late-gadolinium enhancement whole heart MRI

被引:3
|
作者
Peters, Alan A. [1 ]
Wagner, Benedikt [1 ]
Spano, Giancarlo [2 ]
Haupt, Fabian [1 ]
Ebner, Lukas [1 ]
Kunze, Karl-Philipp [3 ]
Schmidt, Michaela [4 ]
Neji, Radhouene [3 ,5 ]
Botnar, Rene [5 ]
Prieto, Claudia [5 ]
Jung, Bernd [1 ]
Christe, Andreas [1 ]
Graeni, Christoph [2 ]
Huber, Adrian T. [1 ]
机构
[1] Univ Bern, Bern Univ Hosp, Dept Diagnost Intervent & Pediat Radiol, Inselspital, Freiburgstr, CH-3010 Bern, Switzerland
[2] Univ Bern, Bern Univ Hosp, Dept Cardiol, Inselspital, Bern, Switzerland
[3] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[4] Siemens Healthcare GmbH, Cardiovasc MR Predev, Erlangen, Germany
[5] Kings Coll London, Sch Biomed Engn & Imaging Sci, St Thomas Hosp, London, England
来源
关键词
Cardiac; Three-dimensional imaging; Magnetic resonance imaging; Cardiomyopathies; Pericardium; Myocardium; CARDIOVASCULAR MAGNETIC-RESONANCE; DELAYED CONTRAST ENHANCEMENT;
D O I
10.1007/s10554-022-02701-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to investigate the diagnostic accuracy and reader confidence for late-gadolinium enhancement (LGE) detection of a novel free-breathing, image-based navigated 3D whole-heart LGE sequence with fat-water separation, compared to a free-breathing motion-corrected 2D LGE sequence in patients with ischemic and non-ischemic cardiomyopathy. Cardiac MRI patients including the respective sequences were retrospectively included. Two independent, blinded readers rated image quality, depiction of segmental LGE and documented acquisition time, SNR, CNR and amount of LGE. Results were compared using the Friedman or the Kruskal-Wallis test. For LGE rating, a jackknife free-response receiver operating characteristic analysis was performed with a figure of merit (FOM) calculation. Forty-two patients were included, thirty-two were examined with a 1.5 T-scanner and ten patients with a 3 T-scanner. The mean acquisition time of the 2D sequence was significantly shorter compared to the 3D sequence (07:12 min vs. 09:24 min; p < 0.001). The 3D scan time was significantly shorter when performed at 3 T compared to 1.5 T (07:47 min vs. 09:50 min; p < 0.001). There were no differences regarding SNR, CNR or amount of LGE. 3D imaging had a significantly higher FOM (0.89 vs. 0.78; p < 0.001). Overall image quality ratings were similar, but 3D sequence ratings were higher for fine anatomical structures. Free-breathing motion-corrected 3D LGE with high isotropic resolution results in enhanced LGE-detection with higher confidence and better delineation of fine structures. The acquisition time for 3D imaging was longer, but may be reduced by performing on a 3 T-scanner.
引用
收藏
页码:135 / 144
页数:10
相关论文
共 21 条
  • [1] Myocardial scar detection in free-breathing Dixon-based fat- and water-separated 3D inversion recovery late-gadolinium enhancement whole heart MRI
    Alan A. Peters
    Benedikt Wagner
    Giancarlo Spano
    Fabian Haupt
    Lukas Ebner
    Karl-Philipp Kunze
    Michaela Schmidt
    Radhouene Neji
    René Botnar
    Claudia Prieto
    Bernd Jung
    Andreas Christe
    Christoph Gräni
    Adrian T. Huber
    The International Journal of Cardiovascular Imaging, 2023, 39 : 135 - 144
  • [2] Accuracy of self-navigated free-breathing isotropic 3D whole heart inversion recovery magnetic resonance for detection of myocardial infarction
    Tobias Rutz
    Davide Piccini
    Jerome Chaptinel
    Simone Coppo
    Gabriella Vincenti
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [3] 3D free-breathing late gadolinium enhancement 3T MRI: comparison with standard 2D Imaging
    Maurice Bizino
    Qian Tao
    Jacob Amersfoort
    Rob J van der Geest
    Hildo J Lamb
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [4] Steadily Increasing Inversion Time Improves Blood Suppression for Free-Breathing 3D Late Gadolinium Enhancement MRI With Optimized Dark-Blood Contrast
    Holtackers, Robert J.
    Gommers, Suzanne
    Van De Heyning, Caroline M.
    Mihl, Casper
    Smink, Jouke
    Higgins, David M.
    Wildberger, Joachim E.
    ter Bekke, Rachel M. A.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (05) : 335 - 340
  • [5] Border sharpness of scar tissue after myocardial infarction as determined by self-navigated free-breathing isotropic 3D whole-heart inversion recovery magnetic resonance
    Tobias Rutz
    Giulia Ginami
    Davide Piccini
    Jérôme Chaptinel
    Simone Coppo
    Gabriella Vincenti
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [6] FREE-BREATHING 3D LATE GADOLINIUM ENHANCEMENT CARDIAC MR FOR THE EVALUATION OF LEFT VENTRICULAR INFARCTION IN A SWINE MYOCARDIAL INFARCTION MODEL
    Lu, Minjie
    Zhao, Shihua
    HEART, 2012, 98 : E71 - E72
  • [7] Comparison of free breathing 3D mDIXON with single breath-hold 3D inversion recovery sequences for the assessment of Late Gadolinium Enhancement
    Dessouky, Riham
    De Stasio, Vincenzo
    Boccalini, Sara
    Si-Mohamed, Salim
    Broussaud, Thomas
    Douek, Philippe
    Sigovan, Monica
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 134
  • [8] Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE
    Pennig, Lenhard
    Lennartz, Simon
    Wagner, Anton
    Sokolowski, Marcel
    Gajzler, Matej
    Ney, Svenja
    Laukamp, Kai Roman
    Persigehl, Thorsten
    Bunck, Alexander Christian
    Maintz, David
    Weiss, Kilian
    Naehle, Claas Philip
    Doerner, Jonas
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [9] Clinical application of free-breathing 3D whole heart late gadolinium enhancement cardiovascular magnetic resonance with high isotropic spatial resolution using Compressed SENSE
    Lenhard Pennig
    Simon Lennartz
    Anton Wagner
    Marcel Sokolowski
    Matej Gajzler
    Svenja Ney
    Kai Roman Laukamp
    Thorsten Persigehl
    Alexander Christian Bunck
    David Maintz
    Kilian Weiss
    Claas Philip Naehle
    Jonas Doerner
    Journal of Cardiovascular Magnetic Resonance, 22
  • [10] Performance of a new gadolinium-based intravascular contrast agent in free-breathing inversion-recovery 3D coronary MRA
    Huber, ME
    Paetsch, I
    Schnackenburg, B
    Bornstedt, A
    Nagel, E
    Fleck, E
    Boesiger, P
    Maggioni, F
    Cavagna, FM
    Stuber, M
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) : 115 - 121