Information fusion of stationary, mobile, and wearable consumer-grade sensors to confidently estimate bedroom ventilation rates

被引:3
|
作者
Fritz, Hagen [1 ]
Wu, Congyu [2 ]
Novoselac, Atila [1 ]
Kinney, Kerry [1 ]
Nagy, Zoltan [1 ]
机构
[1] Univ Texas Austin, Dept Civil Architectural & Environm Engn, Austin, TX 78712 USA
[2] Univ Texas Austin, Dept Psychol, Austin, TX 78712 USA
关键词
Field study; Indoor air quality; Low-cost sensors; Occupancy detection; Ventilation; INDOOR AIR-QUALITY; ENVIRONMENTAL-QUALITY; CARDIOVASCULAR HEALTH; RESPIRATORY HEALTH; CARBON-DIOXIDE; SLEEP; EXPOSURE; DWELLINGS; POLLUTION; SYSTEM;
D O I
10.1016/j.buildenv.2023.109997
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study adds to the body of research investigating ventilation rates measured in residential dwellings. Using open-source Consumer-Grade Sensors (CGS), we measure Carbon Dioxide (CO2) to estimate ventilation rates under one of three conditions: CO2 build-up when bedrooms were initially occupied, steady-state CO2 during the latter half of participants' sleep episodes, and CO2 decay after participants wake and vacate their bedroom. We do not ask participants to record their bedroom occupancy, but use information fusion to identify nightly occupied periods by cross-referencing home addresses to GPS measurements provided by their smartphones during sleep episodes identified by Fitbit wearable fitness trackers. We estimate 106 ventilation rates during build-up conditions which ranged from 0.04-1.36 h-1, 242 ventilation rates under steady-state conditions spanning 0.17-2.49 h-1, and 39 ventilation rates from decay conditions over a range of 0.06-1.05 h-1. In addition, we used occupied periods alongside times when GPS confirmed participants were away from home to label Indoor Air Quality (IAQ) data, and to train a Multi-Layer Perceptron (MLP) to classify occupancy based on CO2 and Total Volatile Organic Compound (TVOC) measurements. Using periods classified as occupied with at least 90% confidence, we estimated 116 additional steady-state ventilation rates spanning 0.25-2.49 h-1. Our results are consistent with more traditional and costly sensing approaches, and we conclude that information fusion of CGS is effective in measuring IAQ, detecting occupancy, and estimating ventilation rates.
引用
收藏
页数:13
相关论文
共 5 条
  • [1] Utilizing Consumer-grade Wearable Sensors for Unobtrusive Rehabilitation Outcome Prediction
    Conci, Jason
    Sprint, Gina
    Cook, Diane
    Weeks, Douglas
    2019 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL & HEALTH INFORMATICS (BHI), 2019,
  • [2] Estimating Internal Biomechanical Forces During Running Using Consumer-grade Wearable Sensors
    Davis, John J.
    Meardon, Stacey A.
    Harezlak, Jaroslaw
    Gruber, Allison H.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 557 - 557
  • [3] The mobile sleep lab app: An open-source framework for mobile sleep assessment based on consumer-grade wearable devices
    Burgdorf, Andreas
    Guethe, Inga
    Jovanovic, Marko
    Kutafina, Ekaterina
    Kohlschein, Christian
    Bitsch, Jo Agila
    Jonas, Stephan M.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 103 : 8 - 16
  • [4] Peripheral-Free Calibration Method for Redundant IMUs Based on Array-Based Consumer-Grade MEMS Information Fusion
    Liang, Siyuan
    Dong, Xiaochao
    Guo, Tianyu
    Zhao, Feng
    Zhang, Yuhua
    MICROMACHINES, 2022, 13 (08)
  • [5] Insect Protein Content Analysis in Handcrafted Fitness Bars by NIR Spectroscopy. Gaussian Process Regression and Data Fusion for Performance Enhancement of Miniaturized Cost-Effective Consumer-Grade Sensors
    Bec, Krzysztof B.
    Grabska, Justyna
    Plewka, Nicole
    Huck, Christian W.
    MOLECULES, 2021, 26 (21):