Maximum Safety Limits of Laminectomy of the C1 Vertebra for Chiari Malformation Surgery: A Finite Element Analysis

被引:0
|
作者
Kayalar, Ali Erhan [1 ]
Yaltirik, Cumhur Kaan [2 ]
Kalyoncu, Enes [3 ]
Bolat, Berna [4 ]
Temiztas, Birgul Ascioglu [4 ]
Etli, Mustafa Umut [5 ]
Calisaneller, Arif Tarkan [1 ]
Naderi, Sait [6 ]
机构
[1] Hlth Sci Univ, Haydarpasa Training & Res Hosp, Dept Neurosurg, Uskudar, Istanbul, Turkiye
[2] Hlth Sci Univ, Umraniye Training & Res Hosp, Dept Neurosurg, Istanbul, Turkiye
[3] Istanbul Gelisim Vocat Sch, Dept Machinery, Istanbul, Turkiye
[4] Yildiz Tech Univ, Fac Mech Engn, Istanbul, Turkiye
[5] Siverek State Hosp, Dept Neurosurg, Sanliurfa, Turkiye
[6] Istanbul Brain & Spine Ctr, Dept Neurosurg, Istanbul, Turkiye
关键词
Chiari; Finite element; Laminectomy; Limit; ANTERIOR ARCH; BIOMECHANICAL ANALYSIS; ATLAS; FRACTURE; SPINE; FUSION; ADULTS;
D O I
10.1007/s43465-023-00870-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThe treatment of Chiari malformations generally consists of posterior fossa decompression. C1 laminectomy is required in selected cases. However, cases of iatrogenic anterior arch fractures at C1 without high-energy trauma have been reported. Developing theoretical models of atlas C1 bones that have undergone a laminectomy can help researchers identify the regions where fractures may occur as a result of sudden loads.MethodsIn this study, we created a detailed three-dimensional solid finite element model of the human atlas bone (C1) using geometric data. The loadings of the laminectomy dimension were evaluated on the basis of three groups. Group I comprised atlas bones that had not undergone a laminectomy. For Group II, the lateral border of the laminectomy was determined as the projection of the lateral mass medial border on the lamina. For Group III, the bilateral sulcus arteriosus was determined as the border for the lateral border of the laminectomy. The analysis results, which are in good agreement with those of previous reports, showed high concentrations of localized stress in the anterior and posterior arches of the atlas bone.ResultsThe analysis results showed that the stress increased in the laminectomy models. The maximum stress observed was consistent with the clinical observations of fracture sites in previous studies.ConclusionIn the treatment of patients with Chiari malformations, C1 laminectomy is often required. The width of this laminectomy can lead to iatrogenic anterior arch fractures. This is the first study to evaluate C1 laminectomy width using finite element modeling.
引用
收藏
页码:884 / 890
页数:7
相关论文
共 50 条
  • [1] Maximum Safety Limits of Laminectomy of the C1 Vertebra for Chiari Malformation Surgery: A Finite Element Analysis
    Ali Erhan Kayalar
    Cumhur Kaan Yaltırık
    Enes Kalyoncu
    Berna Bolat
    Birgül Ascioglu Temiztas
    Mustafa Umut Etli
    Arif Tarkan Çalışaneller
    Sait Naderi
    [J]. Indian Journal of Orthopaedics, 2023, 57 : 884 - 890
  • [2] Bilateral Vocal Cord Abduction Paralysis after C1 Laminectomy in a Child with Type 1 Arnold Chiari Malformation.
    Vafa, Aliyar Zahedi
    Hans, Stephane
    Khalife, Mohamad
    Lechien, Jerome R.
    [J]. ENT-EAR NOSE & THROAT JOURNAL, 2023,
  • [3] Effectiveness of C1 Laminectomy for Chiari Malformation Type 1: Posterior Fossa Volume Expansion and Syrinx-Volume Decrease Rate
    Hwang, Jun Kyu
    Park, Eun Kyung
    Shim, Kyu-Won
    Kim, Dong-Seok
    [J]. YONSEI MEDICAL JOURNAL, 2023, 64 (03) : 191 - 196
  • [4] C1 finite element analysis in gradient enhanced continua
    Manzari, Majid T.
    Yonten, Karma
    [J]. MATHEMATICAL AND COMPUTER MODELLING, 2013, 57 (9-10) : 2519 - 2531
  • [5] Anatomical and computed tomographic analysis of C1 vertebra
    Naderi, S
    Çakmakçi, H
    Acar, F
    Arman, C
    Mertol, T
    Arda, MN
    [J]. CLINICAL NEUROLOGY AND NEUROSURGERY, 2003, 105 (04) : 245 - 248
  • [6] Spontaneous anterior arch fracture of the atlas following C1 laminectomy without fusion: A report of three cases and finite element analysis
    Shimizu, Takayoshi
    Otsuki, Bungo
    Fujibayashi, Shunsuke
    Takemoto, Mitsuru
    Ito, Hideo
    Sakamoto, Takeshi
    Adachi, Taiji
    Matsuda, Shuichi
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (03) : 306 - 315
  • [7] Finite element analysis of the distortion of Z C1 worm drive
    Li, Xiuzhen
    Lu, Baoxiang
    Li, Guitao
    Zhang, Jianliang
    Wang, Shuren
    [J]. Ji Xie She Ji Yu Yian Jiu/Machine Design and Research, 15 (02):
  • [8] C1 macroelements in adaptive finite element methods
    Stogner, Roy H.
    Carey, Graham F.
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2007, 70 (09) : 1076 - 1095
  • [9] Nonlinear geometric analysis of multilayered plates: A new C1 finite element
    Polit, Olivier
    Touratier, Maurice
    [J]. Revue Europeenne des Elements, 2000, 9 (1-3): : 295 - 314
  • [10] Flexural analysis of symmetric laminated composite beams using C1 finite element
    Subramanian, P
    [J]. COMPOSITE STRUCTURES, 2001, 54 (01) : 121 - 126