Safety and effectiveness of the three-dimensional-printed guide plate-assisted rotation axis positioning of a hinged external fixator for the elbow

被引:0
|
作者
Ma, Pengcheng [1 ]
Zheng, Jiachun [1 ]
Chen, Huizhi [1 ]
Yang, Weijie [1 ]
Gao, Hongwei [1 ]
机构
[1] Shandong Publ Hlth Clin Ctr, Dept Trauma Surg, Jinan, Shandong, Peoples R China
关键词
Elbow injuries; External fixators; Rotation axis; Printing; Three-dimensional; Prognosis; TERRIBLE TRIAD; FRACTURE; COMPLICATIONS; DISLOCATIONS; INSTABILITY; SURGERY; RISK;
D O I
10.1007/s00264-024-06134-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose We aimed to evaluate the safety and effectiveness of three-dimensional (3D)-printed guide plates for assisting in the positioning of the rotation axis of an elbow-hinged external fixator. Methods Terrible triad (TT) patients, who were screened using the predefined inclusion and exclusion criteria, underwent installation of a hinged external fixator on the basis of internal fixation; 3D-printed guide plates, generated from the patient's imaging data, assisted in positioning the rotation axis. All patients received the same peri-operative management and were followed up at six, 12, 24, and 48 weeks postoperatively. The duration of positioning pin placement, the number of fluoroscopies, pin placement success rate, types and incidence of post-operative complications, and the Mayo elbow performance score (MEPS) of the diseased elbow and range of motion (ROM) of both elbows were assessed. Results In 25 patients who completed the follow-up, the average time required for positioning pin placement was 329.32 +/- 42.38 s (263-443 s), the average number of fluoroscopies was 2.32 +/- 0.48 times (2-3 times), and the pin placement success rate was 100%. At the last follow-up, the mean MEPS of the diseased elbow was 97.50 +/- 6.92 (75-100), with an excellent and good rate of 100%, and all patients demonstrated stable concentric reduction. The average range of flexion and extension was 135.08 degrees +/- 17.10 degrees (77-146 degrees), while the average range of rotation was 169.21 degrees +/- 18.14 degrees (108-180 degrees). No significant difference was observed in the average ROM between the both elbows (P > 0.05). Eight (32%) patients developed post-operative complications, including elbow stiffness due to heterotopic ossification in three (12%) patients, all of whom did not require secondary intervention. Conclusion Utilizing 3D-printed guide plates for positioning the rotation axis of an elbow-hinged external fixator significantly reduced intra-operative positioning pin placement time and the number of fluoroscopies with excellent positioning results. Satisfactory results were also obtained in terms of post-operative complications, elbow ROM, and functional scores.
引用
收藏
页码:1799 / 1808
页数:10
相关论文
共 11 条
  • [1] A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study
    Yang, Fan
    Yao, Sheng
    Chen, Kai-fang
    Zhu, Feng-zhao
    Xiong, Ze-kang
    Ji, Yan-hui
    Sun, Ting-fang
    Guo, Xiao-dong
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [2] A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study
    Fan Yang
    Sheng Yao
    Kai-fang Chen
    Feng-zhao Zhu
    Ze-kang Xiong
    Yan-hui Ji
    Ting-fang Sun
    Xiao-dong Guo
    BMC Musculoskeletal Disorders, 19
  • [3] Postoperative Three-Dimensional Evaluation of Mandibular Contouring Surgery Using Computer-Assisted Simulation Planning and a Three-Dimensional-Printed Surgical Guide
    Seok, Hyun
    Kim, Seong-Gon
    Park, Young-Wook
    Lee, Yong-Chan
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (03) : 768 - 770
  • [4] The effectiveness and safety of 3-dimensional printed composite guide plate for atlantoaxial pedicle screw A retrospective study
    Wang, Fei
    Li, Chang-Hong
    Liu, Zhi-Bin
    Hua, Zhang-Jian
    He, Yong-Jin
    Liu, Jun
    Liu, Yan-Xiong
    Qiao, Li-Na
    Dang, Xiao-Qian
    MEDICINE, 2019, 98 (01)
  • [5] A novel “three-dimensional-printed individual guide template-assisted percutaneous vertebroplasty” for osteoporotic vertebral compression fracture: a prospective, controlled study
    Pei Lun Hu
    Ji Sheng Lin
    Hai Meng
    Nan Su
    Yong Yang
    Qi Fei
    Journal of Orthopaedic Surgery and Research, 16
  • [6] A novel "three-dimensional-printed individual guide template-assisted percutaneous vertebroplasty" for osteoporotic vertebral compression fracture: a prospective, controlled study
    Hu, Pei Lun
    Lin, Ji Sheng
    Meng, Hai
    Su, Nan
    Yang, Yong
    Fei, Qi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [7] A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures
    Feng Qiao
    Dichen Li
    Zhongmin Jin
    Dingjun Hao
    Yonghua Liao
    Sihai Gong
    International Orthopaedics, 2016, 40 : 835 - 841
  • [8] A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures
    Qiao, Feng
    Li, Dichen
    Jin, Zhongmin
    Hao, Dingjun
    Liao, Yonghua
    Gong, Sihai
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (04) : 835 - 841
  • [9] Three-dimensional-printed guide plate for direct percutaneous pedicle screw implantation in minimally invasive transforaminal lumbar interbody fusion surgery: a retrospective study of 162 patients
    Fan, Xin-Cheng
    Zhao, Da-Wang
    Zhao, Yi-Xiang
    Liu, Feng
    Cheng, Lei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):
  • [10] Three-dimensional analysis of puncture needle path through safety triangle approach PLD and design of puncture positioning guide plate
    Yu, Penghui
    Li, Yanbing
    Zhao, Qidong
    Chen, Xia
    Wu, Liqin
    Jiang, Shuai
    Rao, Libing
    Rao, Yihua
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (03) : 825 - 837