A time-resolved fluorescent microsphere-lateral flow immunoassay strip assay with image visual analysis for quantitative detection of Helicobacter pylori in saliva

被引:12
|
作者
Wang, Yilu [1 ]
Chen, Qiming [1 ]
Wang, Yingying [1 ]
Tu, Fangmin [1 ]
Chen, Xiaodi [1 ]
Li, Junhai [2 ,3 ]
Liu, Zhanmin [1 ,4 ]
机构
[1] Shanghai Univ, Sch Life Sci, Shanghai 200444, Peoples R China
[2] 215 Hosp Shaanxi Nucl Ind, Dept Oncol, Xianyang City 712000, Shaanxi Provinc, Peoples R China
[3] 215 Hosp Shaanxi Nucl Ind, Dept Oncol, 35 West Weiyang Rd, Xianyang City 712000, Shaanxi Provinc, Peoples R China
[4] Shanghai Univ, Sch Life Sci, 381 Nanchen Rd, Shanghai 200444, Peoples R China
关键词
Helicobacter pylori; Time-resolved fluorescent microsphere; Lateral flow immunoassay; Saliva; Self-test; GASTRIC BIOPSIES; ORAL SAMPLES; PCR; IDENTIFICATION; ERADICATION; INFECTION; DIAGNOSIS; DISEASE;
D O I
10.1016/j.talanta.2023.124317
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Helicobacter pylori (H. pylori) is a kind of microaerobic and food-borne pathogen. More than 4.4 billion in-dividuals have been infected by H. pylori and H. pylori was listed as Group I carcinogen by WHO in 1994. Considering the high infection rate of H. pylori and the limited medical resources, self-testing is helpful for diagnosis and timely treatment. Although the amount of H. pylori in human saliva is low, the sampling of saliva is simple and convenient compared with stomach, blood and stool samples. Therefore, H. pylori in human saliva can be an indicator for self-testing, and a sensitive and easy-to-use assay is necessary. In this study, we developed a time-resolved fluorescent microsphere-lateral flow immunoassay (TRFM-LFIA) strip assay with image visual analysis for detection of H. pylori in saliva. The detection of the TRFM-LFIA strip was easy to use and had a low dependency on equipment. With optimized preparation and detection parameters, the whole detection process could be finished in 8 min and the LOD by naked eyes was 102 CFU/mL. For quantitative analysis by image visual analysis, the LOD was as low as 1.05 CFU/mL in the linear range of 101-105 CFU/mL. Besides, the TRFM-LFIA strip also had good stability, reliability, repeatability and accuracy. All these advantages indicated that the TRFM-LFIA strips developed in this study had a good potential for self-testing for H. pylori infection.
引用
收藏
页数:9
相关论文
共 30 条
  • [1] A time-resolved fluorescence microsphere-lateral flow immunochromatographic strip for quantitative detection of Pregnanediol-3-glucuronide in urine samples
    Lin, Jiasheng
    Li, Sanhua
    Ye, Benchen
    Zheng, Weigang
    Wang, Huihui
    Liu, Ying
    Wang, Dong
    Wu, Zaihui
    Dong, Wen-Fei
    Zan, Minghui
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [2] Time-resolved fluorescent microsphere lateral flow biosensors for rapid detection of Candidatus Liberibacter asiaticus
    Su, Cong
    Ding, Fang
    Wang, Wenjing
    Song, Zhiyong
    Ali, Qurban
    Ali, Mubassir
    Hong, Ni
    Wang, Guoping
    Han, Heyou
    PLANT BIOTECHNOLOGY JOURNAL, 2022, 20 (07) : 1235 - 1237
  • [3] A monoclonal antibody-based time-resolved fluorescence microsphere lateral flow immunoassay for paclobutrazol detection
    Cheng, Yongjian
    Xie, Bo
    Liang, Yifan
    Liu, Xinmei
    Chen, Haojie
    Li, Jiadong
    Lei, Hongtao
    Xiao, Zhili
    CURRENT RESEARCH IN FOOD SCIENCE, 2022, 5 : 1395 - 1402
  • [4] Highly sensitive time-resolved fluorescent microspheres lateral flow immunoassay for the quantitative detection of triadimefon and its metabolite residues in fruits and vegetables
    Shi, San-Jun
    Ji, Mei-Qi
    Huang, Rong-Fu
    Fan, Zi-Yan
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [5] A novel time-resolved fluorescent lateral flow immunoassay for quantitative detection of the trauma brain injury biomarker-glial fibrillary acidic protein
    Natarajan, Satheesh
    Joseph, Jayaraj
    SENSORS & DIAGNOSTICS, 2022, 1 (01): : 193 - 197
  • [6] Time-resolved fluorescent lateral flow strip for easy and rapid quality control of edible oil
    Wu, Qian
    Yao, Li
    Qin, Panzhu
    Xu, Jianguo
    Sun, Xun
    Yao, Bangben
    Ren, Fei
    Chen, Wei
    FOOD CHEMISTRY, 2021, 357 (357)
  • [7] A time-resolved fluorescence lateral flow immunoassay for rapid and quantitative serodiagnosis of Brucella infection in humans
    Lu, Jinhui
    Wu, Ze
    Liu, Bochao
    Wang, Cong
    Wang, Qi
    Zhang, Ling
    Wang, Zhen
    Chen, Chuangfu
    Fu, Yongshui
    Li, Chengyao
    Li, Tingting
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 200
  • [8] Development of a Time-Resolved Fluorescent Microsphere Test Strip for Rapid, On-Site, and Sensitive Detection of Picoxystrobin in Vegetables
    Chen, Junjie
    Chen, Lidan
    Zhang, Yongyi
    Xiang, Siyi
    Zhang, Ruizhou
    Shen, Yudong
    Liao, Jiaming
    Xie, Huahui
    Yang, Jinyi
    FOODS, 2024, 13 (03)
  • [9] Rapid, on-site quantitative determination of mycotoxins in grains using a multiple time-resolved fluorescent microsphere immunochromatographic test strip
    Liang, Junfa
    Li, Xuewei
    Huang, Bin
    Pan, Yupeng
    Zhuang, Zile
    Ye, Qiuxiong
    Peng, Cheng
    Deng, Huangyi
    Yi, Yunting
    Zhang, Binbin
    Chen, Peiyi
    Chen, Xuncai
    BIOSENSORS & BIOELECTRONICS, 2024, 258
  • [10] A visual denaturation bubble-mediated strand exchange amplification and RGB visual analysis-based assay for quantitative detection of Helicobacter pylori in saliva
    Yingying Wang
    Qiming Chen
    Yilu Wang
    Xiaodi Chen
    Fangmin Tu
    Junhai Li
    Zhanmin Liu
    Analytical Sciences, 2023, 39 : 483 - 491