Patient specific quality assurance in SBRT: a systematic review of measurement-based methods

被引:3
|
作者
Malatesta, Tiziana [1 ]
Scaggion, Alessandro [2 ]
Giglioli, Francesca Romana [3 ]
Belmonte, Gina [4 ]
Casale, Michelina [5 ]
Colleoni, Paolo [6 ]
Falco, Maria Daniela [7 ]
Giuliano, Alessia [8 ]
Linsalata, Stefania [8 ]
Marino, Carmelo [9 ]
Moretti, Eugenia [10 ]
Richetto, Veronica [3 ]
Sardo, Anna [11 ]
Russo, Serenella [12 ]
Mancosu, Pietro [13 ]
机构
[1] Fatebenefratelli Isola Tiberina Gemelli Isola Hosp, Dept Radiotherapy & Med Oncol & Radiol, Med Phys Unit, Rome, Italy
[2] Veneto Inst Oncol IOV IRCCS, Med Phys Dept, Padua, Italy
[3] AOU Citta Salute & Sci Torino, Med Phys Unit, Turin, Italy
[4] San Luca Hosp, Med Phys Dept, Lucca, Italy
[5] Azienda Osped Santa Maria, Med Phys Unit, Terni, Italy
[6] ASST Papa Giovanni XXIII, UOC Med Phys Unit, Bergamo, Italy
[7] Univ G dAnnunzio, SS Annunziata Hosp, Dept Radiat Oncol, Chieti, Italy
[8] Azienda Osped Univ Pisana, Pisa Univ Hosp, Med Phys Unit, Pisa, Italy
[9] Human Ist Clin Catanese, Med Phys & Radioprotect Unit, Misterbianco, CT, Italy
[10] ASUFC Udine, Dept Oncol, Div Med Phys, Udine, Italy
[11] ASLCN2, UOSD Med Phys, Verduno, Italy
[12] Azienda USL Toscana Ctr, Med Phys Unit, Florence, Italy
[13] IRCCS Human Res Hosp, Radiotherapy Dept, Med Phys Unit, Rozzano Milano, Italy
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 21期
关键词
SBRT; treatment planning; patient specific QA reproducibility; BODY RADIATION-THERAPY; PHASE-II TRIAL; GAMMA INDEX; POLYMER GEL; QA; RADIOTHERAPY; DOSIMETRY; VERIFICATION; SRS; SENSITIVITY;
D O I
10.1088/1361-6560/acf43a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This topical review focuses on Patient-Specific Quality Assurance (PSQA) approaches to stereotactic body radiation therapy (SBRT). SBRT requires stricter accuracy than standard radiation therapy due to the high dose per fraction and the limited number of fractions. The review considered various PSQA methods reported in 36 articles between 01/2010 and 07/2022 for SBRT treatment. In particular comparison among devices and devices designed for SBRT, sensitivity and resolution, verification methodology, gamma analysis were specifically considered. The review identified a list of essential data needed to reproduce the results in other clinics, highlighted the partial miss of data reported in scientific papers, and formulated recommendations for successful implementation of a PSQA protocol.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Comparing log file to measurement-based patient-specific quality assurance
    Li Ting Chan
    Yun Inn Tan
    Poh Wee Tan
    Yuh Fun Leong
    Jong Shin Khor
    Mun Woan Teh
    Joan Faith Loria Cruz
    Sháun Peter Baggarley
    Kiat Huat Ooi
    Yiat Horng Leong
    Physical and Engineering Sciences in Medicine, 2023, 46 : 303 - 311
  • [2] Comparing log file to measurement-based patient-specific quality assurance
    Ting, Chan Li
    Inn, Tan Yun
    Wee, Tan Poh
    Leong, Leong Yuh
    Shin, Khor Jong
    Woan, Teh Mun
    Cruz, Joan Faith Loria
    Baggarley, Shaun Peter
    Huat, Ooi Kiat
    Leong, Leong Yiat
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 303 - 311
  • [3] Artificial intelligence for prediction of measurement-based patient-specific quality assurance is ready for prime time
    Valdes, Gilmer
    Adamson, Justus
    Cai, Jing
    MEDICAL PHYSICS, 2021, 48 (06) : 2701 - 2704
  • [4] Predicting Measurement-Based Patient-Specific Quality Assurance Results for ViewRay Plans Using Machine Learning
    Witztum, A.
    Ibrahim, G.
    Wall, P.
    Lamb, J.
    Valdes, G.
    MEDICAL PHYSICS, 2022, 49 (06) : E131 - E131
  • [5] Transitioning from measurement-based to combined patient-specific quality assurance for intensity-modulated proton therapy
    Chen, Mei
    Yepes, Pablo
    Hojo, Yoshifumi
    Poenisch, Falk
    Li, Yupeng
    Chen, Jiayi
    Xu, Cheng
    He, Xiaodong
    Gunn, G. Brandon
    Frank, Steven J.
    Sahoo, Narayan
    Li, Heng
    Zhu, Xiaorong Ronald
    Zhang, Xiaodong
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1107):
  • [6] FMEA Based Comparison of Measurement and Software Based Patient Specific Quality Assurance
    Studinski, Ryan
    Abbas, Ahmar
    Abdellatif, Ady
    Bissonnette, Jean-Pierre
    Conroy, Leigh
    King, Jenna
    Nusra, Humza
    Oliver, Mike
    Rangel, Alejandra
    Xhaferllari, Ilma
    Weston, Mark
    MEDICAL PHYSICS, 2024, 51 (08) : 5830 - 5831
  • [7] Evaluation of Patient-Specific Quality Assurance Based On Different Methods
    Yang, T.
    Qu, B.
    Dai, X.
    Xie, C.
    Xiaoshen, W.
    Cong, X.
    Wang, J.
    Xu, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 2896 - 2896
  • [8] Evaluation of Patient-Specific Quality Assurance Based On Different Methods
    Lin, X.
    Sun, T.
    Liu, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E211 - E211
  • [9] Is it necessary to perform measurement-based patient-specific quality assurance for online adaptive radiotherapy with Elekta Unity MR-Linac?
    Xu, Yuan
    Xia, Wenlong
    Ren, Wenting
    Ma, Min
    Men, Kuo
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):
  • [10] Comprehensive characterisation of the IBA myQA SRS for SRS and SBRT patient specific quality assurance
    Junis, Izabela
    Yousif, Yousif
    Stensmyr, Rachel
    Barber, Jeffrey
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (01) : 327 - 337