In Vivo Photoacoustic Endoscopy Imaging of Gastrointestinal Model of Septic Small-Animal

被引:2
|
作者
Chen, Xiaolong [1 ]
Liang, Yizhi [1 ]
Zhong, Xiaoxuan [1 ]
Bai, Xue [1 ]
Jin, Long [1 ]
Huang, Wei [2 ]
Huang, Cheng [3 ]
Niu, Xiaobing [4 ]
Guo, Shanshan [4 ]
Guan, Baiou [1 ]
机构
[1] Jinan Univ, Inst Photon Technol, Guangdong Key Lab Opt Fiber Sensing & Commun Techn, Guangzhou 511443, Guangdong, Peoples R China
[2] Jinan Univ, Affiliated Hosp 1, Dept Gastroenterol, Guangzhou 510632, Guangdong, Peoples R China
[3] Guangdong Prov Peoples Hosp, Guangdong Cardiovasc Inst, Guangzhou 510080, Guangdong, Peoples R China
[4] Guangzhou SINCHOO Med Technol Co Ltd, Guangzhou 510535, Guangdong, Peoples R China
来源
关键词
Key words bio-optics; photoacoustic imaging; photoacoustic endoscopy; ultrasound sensors; optical fiber sensors; microcirculatory disturbance; OXYGEN-SATURATION; MICROSCOPY;
D O I
10.3788/CJL221450
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Objective Microcirculatory dysfunction may cause circulatory failure, insufficient oxygen delivery, and fatal risks. Microscopes are used to observe microcirculation, but they can only image superficial tissues. In addition, they can hardly provide functional information. In this study, we report a photoacoustic endoscope for in vivo imaging of the gastrointestinal microcirculation. The imaging probe is inserted into the rectum of a small animal for rotational -scanning endoscopic imaging. The vascular structures in the gastrointestinal wall can be visualized by detecting the ultrasound excited by the pulsed laser. Moreover, the blood oxygen saturation can be measured and imaged with a dual -wavelength excitation based on the difference in the optical absorption spectrum between oxy- and deoxygenated hemoglobin. We believe that this technology is capable of detecting the functional changes associated with microcirculation diseases with minimal invasion. Methods The imaging system consists of an endoscopic imaging probe, dual -wavelength pulsed laser source, rotary scanning device, and data acquisition and control module. First, we design an all -fiber endoscope probe containing two functional optical fibers as follows: one responsible for guiding and focusing the pulsed light and the other equipped with a laser ultrasonic sensor to detect the photoacoustic signal. Second, we design a rotational scanning device that rotates synchronously with the probe to achieve fast and unidirectional rotary scanning. This is achieved by miniaturizing the 980-nm pump laser, the optical amplifier, and the photodetector. Results and Discussions The endoscope probe has a diameter of 2.75 mm, a resolution of 12.5 mu m, signal jitter root mean square of 2.5%, and a B -scan frequency of 1 Hz. The instrument is stable and provides spatial resolution in high-speed scanning and is suitable for small animal digestive tract endoscopic imaging. The functional imaging results of the rectum of healthy rats show that we achieve 360 degrees scanning, obtain the three-dimensional imaging results of hemoglobin concentration distribution, and show the vascular structure of the inner wall of the rat rectum. Along with the spatial distribution of blood oxygen saturation, the images show the distributions of the artery and vein in the inner wall (Fig. 3). The imaging results of septic rats show the changes in microcirculation. According to the imaging result, the number of blood vessels in the intestine of rats gradually decreases, and the blood oxygen saturation also declines in 5 h (Fig. 4). The above results reflect the phenomenon of insufficient tissue perfusion caused by sepsis. Conclusions In summary, we develop a photoacoustic endoscope for in vivo rectal imaging. By using fiber optic ultrasound sensors, the endoscope can image the vascular structure and visualize the changes in oxygen saturation. By using this endoscope, we can visualize the gastrointestinal microcirculatory disorder caused by lesions. The structure, number, and blood oxygen saturation level of blood vessels are significantly changed. The experimental results show that this technology can provide functional imaging results with high spatial resolution and high contrast in the endoscopic imaging of narrow cavity structures, thus providing a feasible imaging method for the characterization of microcirculation status and the diagnosis and treatment of acute and severe diseases.
引用
收藏
页数:9
相关论文
共 42 条
  • [1] Measuring blood oxygen saturation along a capillary vessel in human
    Akons, Kfir
    Dann, Eldad J.
    Yelin, Dvir
    [J]. BIOMEDICAL OPTICS EXPRESS, 2017, 8 (11): : 5342 - 5348
  • [2] Aljada A, 2004, AM J CLIN NUTR, V80, P51
  • [3] Classification of human ovarian cancer using functional, spectral, and imaging features obtained from in vivo photoacoustic imaging
    Amidi, Eghbal
    Mostafa, Atahar
    Nandy, Sreyankar
    Yang, Guang
    Middleton, William
    Siegel, Cary
    Zhu, Quing
    [J]. BIOMEDICAL OPTICS EXPRESS, 2019, 10 (05) : 2213 - 2227
  • [4] [Anonymous], 2004, DIGEST WORLD LATEST, P1165
  • [5] Photoacoustic microscopy for evaluating combretastatin A4 phosphate induced vascular disruption in orthotopic glioma
    Bi, Renzhe
    Balasundaram, Ghayathri
    Jeon, Seungwan
    Tay, Hui Chien
    Pu, Yang
    Li, Xiuting
    Moothanchery, Mohesh
    Kim, Chulhong
    Olivo, Malini
    [J]. JOURNAL OF BIOPHOTONICS, 2018, 11 (10)
  • [6] Nanoparticle and targeted systems for cancer therapy
    Brannon-Peppas, L
    Blanchette, JO
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2004, 56 (11) : 1649 - 1659
  • [7] Transparent High-Frequency Ultrasonic Transducer for Photoacoustic Microscopy Application
    Chen, Ruimin
    He, Yun
    Shi, Junhui
    Yung, Christopher
    Hwang, Jeeseong
    Wang, Lihong V.
    Zhou, Qifa
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (09) : 1848 - 1853
  • [8] Microvascular alterations in patients with acute severe heart failure and cardiogenic shock
    De Backer, D
    Creteur, J
    Dubois, MJ
    Sakr, Y
    Vincent, JL
    [J]. AMERICAN HEART JOURNAL, 2004, 147 (01) : 91 - 99
  • [9] Comparison of buccal microcirculation between septic and hemorrhagic shock
    Fang, Xiangshao
    Tang, Wanchun
    Sun, Shijie
    Huang, Lei
    Chang, Yun-Te
    Castillo, Carlos
    Weil, Max Harry
    [J]. CRITICAL CARE MEDICINE, 2006, 34 (12) : S447 - S453
  • [10] Optical Fiber Photoacoustic Blood Oxygen Saturation Measurement and Functional Imaging
    Fu Wubing
    Liang Yizhi
    Zhong Xiaoxuan
    Huang Jie
    Jin Long
    Guan Baiou
    [J]. ACTA OPTICA SINICA, 2022, 42 (20)