The influence of head strap elasticity on the protective properties of filtering facepiece respirators

被引:0
|
作者
Tretiakova, Larisa [1 ]
Cheberyachko, Yurii [2 ]
Sharovatova, Olena [3 ]
Nehrii, Tetiana [4 ]
Nehrii, Serhii [5 ]
Kravchenko, Bohdan [2 ]
Zolotarova, Oksana [6 ]
机构
[1] Natl Tech Univ Ukraine, Igor Sikorsky Kyiv Polytech Inst, 37 Beresteiskyi Prospect, UA-03056 Kiev, Ukraine
[2] Dnipro Univ Technol, 19 Dmytra Yavornytskoho Ave, UA-49005 Dnipro, Ukraine
[3] Natl Univ Civil Def Ukraine, 94 Chernishevska Str, UA-61023 Kharkov, Ukraine
[4] Kyiv Natl Univ Construct & Architecture, 31 Povitroflotskyi Ave, UA-02000 Kiev, Ukraine
[5] Donetsk Natl Tech Univ, 2 Shybankova Sq, UA-85300 Pokrovsk, Donetsk, Ukraine
[6] Donetsk Natl Tech Univ, 2 Shybankova Sq, Pokrovsk, Donetsk, Ukraine
来源
RUDARSKO-GEOLOSKO-NAFTNI ZBORNIK | 2024年 / 39卷 / 01期
关键词
occupational disease; respiratory protection of workers; filtering mask respirator; elastic strap; improved design; PERFORMANCE; DISEASE; INJURY; MASKS; RISK;
D O I
10.17794/rgn.2024.1.11
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The level of occupational respiratory diseases among workers in the mining, machine-building and metallurgical industries remains high. The most common occupational respiratory disease is pneumoconiosis, which is the result of the long-term inhalation of dust. It is possible to minimize the impact of dust on the workers and eliminate such diseases in the future due to the use of filtering mask respirators designed to reduce dust infiltration into the space under the mask. For this purpose, the choice of the type of elastic bands of filtering mask respirators has been substantiated by the geometric shape and tension forces that can ensure a permissible level of leakage of contaminated air into the breathing zone of the respirator during its use. A mathematical model has been developed to describe the influence of parameters of elastomeric headgear on the protective properties of the respirator. The dependence of the change in the residual tensile strength of the elastic bands of the headband has been established, and the dependence of the volume of air suction on the area of the elastic straps at the corresponding tension force has been determined. Using the model, the dependence of the volume of polluted air inflow on the area of the elastic straps at the corresponding tension force has been estimated. The design of the innovative inserts has been offered, which makes it possible to control the tension of the elastomeric head straps of the respirator to visualize the weakening of the pressure forces responsible for maintaining a tight fit.
引用
收藏
页码:131 / 140
页数:10
相关论文
共 50 条
  • [1] Evaluation of properties of elastomeric head straps of filtering facepiece respirators
    Malgorzata, Okrasa
    Serhii, Cheberyachko
    Dmytro, Radchuk
    Oleg, Deryugin
    Olena, Sharovatova
    INTERNATIONAL JOURNAL OF OCCUPATIONAL SAFETY AND ERGONOMICS, 2023, : 1294 - 1300
  • [2] Understanding Filtering Facepiece Respirators
    Andrews, Angela S.
    Kiederer, Meghan
    Casey, Megan L.
    AMERICAN JOURNAL OF NURSING, 2022, 122 (02) : 21 - 23
  • [3] Strap Performance of N95 Filtering Facepiece Respirators After Multiple Decontamination Cycles
    Aaron W. Richardson
    Kent C. Hofacre
    Patrick H. Keyes
    Rachel M. Thurston
    John D. Clay
    MRS Advances, 2020, 5 : 2881 - 2888
  • [4] Strap performance of N95 filtering facepiece respirators after multiple decontamination cycles
    Richardson, Aaron W.
    Hofacre, Kent C.
    Keyes, Patrick H.
    Thurston, Rachel M.
    Clay, John D.
    MRS BULLETIN, 2021, 46 (02) : 103 - 103
  • [5] Strap Performance of N95 Filtering Facepiece Respirators After Multiple Decontamination Cycles
    Richardson, Aaron W.
    Hofacre, Kent C.
    Keyes, Patrick H.
    Thurston, Rachel M.
    Clay, John D.
    MRS ADVANCES, 2020, 5 (56) : 2881 - 2888
  • [6] Improving the fit of filtering facepiece respirators
    Shah, Kamini
    Serban, Stefan
    Douglas, Gail V. A.
    BRITISH DENTAL JOURNAL, 2022,
  • [7] FIBER RELEASE FROM FILTERING FACEPIECE RESPIRATORS
    HOWIE, RM
    ADDISON, J
    CHERRIE, J
    ROBERTSON, A
    DODGSON, J
    ANNALS OF OCCUPATIONAL HYGIENE, 1986, 30 (01): : 131 - 133
  • [8] Decontamination Methods for Reuse of Filtering Facepiece Respirators
    Su-Velez, Brooke M.
    Maxim, Tom
    Long, Jennifer L.
    St John, Maie A.
    Holliday, Michael A.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2020, 146 (08) : 734 - 740
  • [9] Limited Reuse and Extended Use of Filtering Facepiece Respirators
    Company Sancho, Maria Consuelo
    Gonzalez-Maria, Esther
    Abad-Corpa, Eva
    ENFERMERIA CLINICA, 2021, 31 : S78 - S83
  • [10] Assessing the Fit of N95 Filtering Facepiece Respirators Fitted with an Ear Loop Strap System: A Pilot Study
    Niu, Xinyi
    Koehler, Richard H.
    Yermakov, Michael
    Grinshpun, Sergey A.
    ANNALS OF WORK EXPOSURES AND HEALTH, 2023, 67 (01) : 50 - 58