Contrast-enhanced to non-contrast-enhanced image translation to exploit a clinical data warehouse of T1-weighted brain MRI

被引:0
|
作者
Bottani, Simona [1 ]
Thibeau-Sutre, Elina [1 ]
Maire, Aurelien [2 ]
Stroer, Sebastian [3 ]
Dormont, Didier [4 ]
Colliot, Olivier [1 ]
Burgos, Ninon [1 ]
机构
[1] Sorbonne Univ, Hop Pitie Salpetriere, AP HP, Inst Cerveau,Paris Brain Inst ICM,CNRS,Inria,Inser, F-75013 Paris, France
[2] AP HP, Innovat & Donnees, Dept Serv Numer, F-75013 Paris, France
[3] Hop La Pitie Salpetriere, AP HP, Dept Neuroradiol, F-75012 Paris, France
[4] Sorbonne Univ, Hop Pitie Salpetriere, AP HP, Inst Cerveau,Paris Brain Inst ICM,CNRS,Inria,Inser, F-75013 Paris, France
关键词
Brain MRI; Clinical data warehouse; Image translation; NEURAL-NETWORKS; DEEP; GENERATION;
D O I
10.1186/s12880-024-01242-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundClinical data warehouses provide access to massive amounts of medical images, but these images are often heterogeneous. They can for instance include images acquired both with or without the injection of a gadolinium-based contrast agent. Harmonizing such data sets is thus fundamental to guarantee unbiased results, for example when performing differential diagnosis. Furthermore, classical neuroimaging software tools for feature extraction are typically applied only to images without gadolinium. The objective of this work is to evaluate how image translation can be useful to exploit a highly heterogeneous data set containing both contrast-enhanced and non-contrast-enhanced images from a clinical data warehouse.MethodsWe propose and compare different 3D U-Net and conditional GAN models to convert contrast-enhanced T1-weighted (T1ce) into non-contrast-enhanced (T1nce) brain MRI. These models were trained using 230 image pairs and tested on 77 image pairs from the clinical data warehouse of the Greater Paris area.ResultsValidation using standard image similarity measures demonstrated that the similarity between real and synthetic T1nce images was higher than between real T1nce and T1ce images for all the models compared. The best performing models were further validated on a segmentation task. We showed that tissue volumes extracted from synthetic T1nce images were closer to those of real T1nce images than volumes extracted from T1ce images.ConclusionWe showed that deep learning models initially developed with research quality data could synthesize T1nce from T1ce images of clinical quality and that reliable features could be extracted from the synthetic images, thus demonstrating the ability of such methods to help exploit a data set coming from a clinical data warehouse.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Contrast-enhanced to non-contrast-enhanced image translation to exploit a clinical data warehouse of T1-weighted brain MRI
    Simona Bottani
    Elina Thibeau-Sutre
    Aurélien Maire
    Sebastian Ströer
    Didier Dormont
    Olivier Colliot
    Ninon Burgos
    BMC Medical Imaging, 24
  • [2] Homogenization of brain MRI from a clinical data warehouse using contrast-enhanced to non-contrast-enhanced image translation with U-Net derived models
    Bottani, Simona
    Thibeau-Sutre, Elina
    Maire, Aurelien
    Stroer, Sebastian
    Dormont, Didier
    Colliot, Olivier
    Burgos, Ninon
    MEDICAL IMAGING 2022: IMAGE PROCESSING, 2022, 12032
  • [3] Non-contrast-enhanced T1-weighted MRI of myocardial radiofrequency ablation lesions
    Guttman, Michael A.
    Tao, Susumu
    Fink, Sarah
    Kolandaivelu, Aravindan
    Halperin, Henry R.
    Herzka, Daniel A.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 879 - 889
  • [4] T1-Weighted Contrast-Enhanced Synthesis for Multi-Contrast MRI Segmentation
    Ozbey, Muzaffer
    Cukur, Tolga
    2020 28TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2020,
  • [5] SPGR with Contrast-Enhanced versus SE contrast-enhanced T1-weighted studies of the head
    Farinha, C.
    Tavares, O.
    EUROPEAN JOURNAL OF PUBLIC HEALTH, 2019, 29
  • [6] Modeling of Contrast Agent Kinetics in the Lung Using T1-Weighted Dynamic Contrast-Enhanced MRI
    Naish, Josephine H.
    Kershaw, Lucy E.
    Buckley, David L.
    Jackson, Alan
    Waterton, John C.
    Parker, Geoffrey J. M.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (06) : 1507 - 1514
  • [7] Detection of knee synovitis using non-contrast-enhanced qDESS compared with contrast-enhanced MRI
    de Vries, Bas A.
    Breda, Stephan J.
    Sveinsson, Bragi
    McWalter, Emily J.
    Meuffels, Duncan E.
    Krestin, Gabriel P.
    Hargreaves, Brian A.
    Gold, Garry E.
    Oei, Edwin H. G.
    ARTHRITIS RESEARCH & THERAPY, 2021, 23 (01)
  • [8] Detection of knee synovitis using non-contrast-enhanced qDESS compared with contrast-enhanced MRI
    Bas A. de Vries
    Stephan J. Breda
    Bragi Sveinsson
    Emily J. McWalter
    Duncan E. Meuffels
    Gabriel P. Krestin
    Brian A. Hargreaves
    Garry E. Gold
    Edwin H. G. Oei
    Arthritis Research & Therapy, 23
  • [9] Characteristics and pitfalls of contrast-enhanced, T1-weighted magnetization transfer images of the brain
    Higano, S
    Shrier, DA
    Numaguchi, Y
    Shibata, DK
    Kwok, E
    ACADEMIC RADIOLOGY, 2000, 7 (03) : 156 - 164
  • [10] The role of contrast-enhanced and non-contrast-enhanced MRI in the follow-up of multiple sclerosis
    Zarei, Fariba
    Ghaedian, Mehrnaz
    Ghaedian, Tahereh
    ACTA RADIOLOGICA, 2021, 62 (07) : 916 - 921