Impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion in patients with suspected stroke

被引:0
|
作者
Rau, Alexander [1 ,2 ]
Reisert, Marco [3 ,4 ]
Stein, Thomas [2 ]
Mueller-Peltzer, Katharina [2 ]
Rau, Stephan [2 ]
Bamberg, Fabian [2 ]
Taschner, Christian A. [1 ]
Urbach, Horst [1 ]
Kellner, Elias [3 ]
机构
[1] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Neurol & Clin Neurosci, Freiburg, Germany
[2] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Diagnost & Intervent Radiol, Freiburg, Germany
[3] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Med Phys, Freiburg, Germany
[4] Univ Freiburg, Med Ctr Univ Freiburg, Fac Med, Dept Stereotact & Funct Neurosurg, Freiburg, Germany
关键词
Perfusion; Stroke; Radiation dosage; Computed tomography; ACUTE ISCHEMIC-STROKE; VOLUME; PARAMETERS; SOFTWARE; EXPOSURE;
D O I
10.1007/s00234-024-03335-w
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeCT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke.MethodsWe retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared.ResultsThe agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4.ConclusionReducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.
引用
收藏
页码:749 / 759
页数:11
相关论文
共 50 条
  • [1] Impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion in patients with suspected stroke
    Alexander Rau
    Marco Reisert
    Thomas Stein
    Katharina Mueller-Peltzer
    Stephan Rau
    Fabian Bamberg
    Christian A. Taschner
    Horst Urbach
    Elias Kellner
    Neuroradiology, 2024, 66 : 749 - 759
  • [2] Dynamic perfusion CT Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients
    Kaemena, Andreas
    Streitparth, Florian
    Grieser, Christian
    Lehrnkuhl, Lukas
    Jamil, Basil
    Wojtal, Katarzyna
    Ricke, Jens
    Pech, Maciej
    EUROPEAN JOURNAL OF RADIOLOGY, 2007, 64 (01) : 111 - 118
  • [3] Reduction in radiation dose with reconstruction technique in the brain perfusion CT
    Kim, H. J.
    Lee, H. K.
    Song, H.
    Ju, M. S.
    Dong, K. R.
    Chung, W. K.
    Cho, M. S.
    Cho, J. H.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2011, 166 (12): : 918 - 926
  • [4] Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature
    Othman, Ahmed E.
    Afat, Saif
    Brockmann, Marc A.
    Nikoubashman, Omid
    Brockmann, Carolin
    Nikolaou, Konstantin
    Wiesmann, Martin
    JOURNAL OF NEURORADIOLOGY, 2016, 43 (01) : 1 - 5
  • [5] Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms
    Othman, A. E.
    Afat, S.
    Brockmann, C.
    Nikoubashman, O.
    Bier, G.
    Brockmann, M. A.
    Nikolaou, K.
    Tai, J. H.
    Yang, Z. P.
    Kim, J. H.
    Wiesmann, M.
    CLINICAL NEURORADIOLOGY, 2017, 27 (03) : 311 - 318
  • [6] Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms
    A. E. Othman
    S. Afat
    C. Brockmann
    O. Nikoubashman
    G. Bier
    M. A. Brockmann
    K. Nikolaou
    J. H. Tai
    Z. P. Yang
    J. H. Kim
    M. Wiesmann
    Clinical Neuroradiology, 2017, 27 : 311 - 318
  • [7] Dynamic perfusion CT: Optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients
    Wintermark, M
    Smith, WS
    Ko, NU
    Quist, M
    Schnyder, P
    Dillon, WP
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (05) : 720 - 729
  • [8] Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke
    Othman, Ahmed E.
    Brockmann, Carolin
    Yang, Zepa
    Kim, Changwon
    Afat, Saif
    Pjontek, Rastislav
    Nikobashman, Omid
    Brockmann, Marc A.
    Kim, Jong Hyo
    Wiesmann, Martin
    EUROPEAN RADIOLOGY, 2015, 25 (12) : 3415 - 3422
  • [9] Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke
    Ahmed E. Othman
    Carolin Brockmann
    Zepa Yang
    Changwon Kim
    Saif Afat
    Rastislav Pjontek
    Omid Nikobashman
    Marc A. Brockmann
    Jong Hyo Kim
    Martin Wiesmann
    European Radiology, 2015, 25 : 3415 - 3422
  • [10] Erratum to: Effects of radiation dose reduction in volume perfusion CT imaging of acute ischaemic stroke
    Ahmed E. Othman
    Carolin Brockmann
    Zepa Yang
    Changwon Kim
    Saif Afat
    Rastislav Pjontek
    Omid Nikoubashman
    Marc A. Brockmann
    Jong Hyo Kim
    Martin Wiesmann
    European Radiology, 2018, 28 : 650 - 650